메뉴 건너뛰기




Volumn 127, Issue 4, 2011, Pages

Needle-entry angle for lumbar puncture in children as determined by using ultrasonography

Author keywords

Angle; Interspinous space; Lumbar puncture; Ultrasound

Indexed keywords

ANATOMICAL VARIATION; ARTICLE; CHILD; CLINICAL ARTICLE; CLINICAL PRACTICE; CONTROLLED STUDY; ECHOGRAPHY; FEMALE; GROUPS BY AGE; HUMAN; IMAGE ANALYSIS; INFANT; LIGAMENTUM FLAVUM; LUMBAR PUNCTURE; LUMBAR SPINE; LUMBAR SPINOUS SPACE; MALE; PRESCHOOL CHILD; PRIORITY JOURNAL; RECUMBENCY; SCHOOL CHILD; SITTING; SPINE RADIOGRAPHY;

EID: 79953313638     PISSN: 00314005     EISSN: 10984275     Source Type: Journal    
DOI: 10.1542/peds.2010-2511     Document Type: Article
Times cited : (16)

References (24)
  • 1
    • 0027533331 scopus 로고
    • Role of local anesthesia during lumbar puncture in neonates
    • Pinheiro JM, Furdon S, Ochoa LF. Role of local anesthesia during lumbar puncture in neonates. Pediatrics. 1993;91(2):379-382 (Pubitemid 23042320)
    • (1993) Pediatrics , vol.91 , Issue.2 , pp. 379-382
    • Pinheiro, J.M.B.1    Furdon, S.2    Ochoa, L.F.3
  • 3
    • 77951779098 scopus 로고    scopus 로고
    • Positioning for lumbar puncture in children evaluated by bedside ultrasound
    • Available at
    • Abo A, Chen L, Johnston P, Santucci K. Positioning for lumbar puncture in children evaluated by bedside ultrasound. Pediatrics. 2010;125(5). Available at: www. pediatrics.org/cgi/content/full/125/5/e1149
    • (2010) Pediatrics , vol.125 , Issue.5
    • Abo, A.1    Chen, L.2    Johnston, P.3    Santucci, K.4
  • 4
    • 0020659383 scopus 로고
    • Optimal position for a spinal tap in preterm infants
    • Gleason CA, Martin RJ, Anderson JV, Carlo WA, Sanniti KJ, Fanaroff AA. Optimal position for a spinal tap in preterm infants. Pediatrics. 1983;71(1):31-35 (Pubitemid 13190057)
    • (1983) Pediatrics , vol.71 , Issue.1 , pp. 31-35
    • Gleason, C.A.1    Martin, R.J.2    Anderson, J.V.3
  • 6
    • 0030020516 scopus 로고    scopus 로고
    • Repeated dural punctures increase the incidence of postdural puncture headache
    • DOI 10.1097/00000539-199602000-00015
    • Seeberger MD, Kaufmann M, Staender S, Schneider M, Scheidegger D. Repeated dural punctures increase the incidence of postdural puncture headache. Anesth Analg. 1996;82(2):302-305 (Pubitemid 26055018)
    • (1996) Anesthesia and Analgesia , vol.82 , Issue.2 , pp. 302-305
    • Seeberger, M.D.1    Kaufmann, M.2    Staender, S.3    Schneider, M.4    Scheidegger, D.5
  • 7
    • 0037342797 scopus 로고    scopus 로고
    • Interpretation of traumatic lumbar punctures: Who can go home?
    • Mazor SS, McNulty JE, Roosevelt GE. Interpretation of traumatic lumbar punctures: who can go home [published correction appears in Pediatrics. 2003;111(5):1127]? Pediatrics. 2003;111(3):525-528 (Pubitemid 36330707)
    • (2003) Pediatrics , vol.111 , Issue.3 , pp. 525-528
    • Mazor, S.S.1    McNulty, J.E.2    Roosevelt, G.E.3
  • 8
    • 33645025988 scopus 로고    scopus 로고
    • Local anesthetic and stylet styles: Factors associated with resident lumbar puncture success
    • DOI 10.1542/peds.2005-0519
    • Baxter AL, Fisher RG, Burke BL, Goldblatt SS, Isaacman DJ, Lawson ML. Local anesthetic and stylet styles: factors associated with resident lumbar puncture success. Pediatrics. 2006;117(3):876-881 (Pubitemid 46063232)
    • (2006) Pediatrics , vol.117 , Issue.3 , pp. 876-881
    • Baxter, A.L.1    Fisher, R.G.2    Burke, B.L.3    Goldblatt, S.S.4    Isaacman, D.J.5    Lawson, M.L.6
  • 9
    • 34248570107 scopus 로고    scopus 로고
    • Risk Factors for Traumatic or Unsuccessful Lumbar Punctures in Children
    • DOI 10.1016/j.annemergmed.2006.10.018, PII S0196064406024504
    • Nigrovic LE, Kuppermann N, Neuman MI. Risk factors for traumatic or unsuccessful lumbar punctures in children. Ann Emerg Med. 2007;49(6):762-771 (Pubitemid 46755433)
    • (2007) Annals of Emergency Medicine , vol.49 , Issue.6 , pp. 762-771
    • Nigrovic, L.E.1    Kuppermann, N.2    Neuman, M.I.3
  • 10
    • 0021339551 scopus 로고
    • Measurement of the depth to the extradural space using ultrasound
    • Currie JM. Measurement of the depth to the extradural space using ultrasound. Br J Anaesth. 1984;56(4):345-347 (Pubitemid 14148417)
    • (1984) British Journal of Anaesthesia , vol.56 , Issue.4 , pp. 345-347
    • Currie, J.M.1
  • 11
    • 0018837951 scopus 로고
    • Ultrasonic localization of the lumbar epidural space
    • Cork RC, Kryc JJ, Vaughan RW. Ultrasonic localization of the lumbar epidural space. Anesthesiology. 1980;52(6):513-516 (Pubitemid 10114445)
    • (1980) Anesthesiology , vol.52 , Issue.6 , pp. 513-516
    • Cork, R.C.1    Kryc, J.J.2    Vaughan, R.W.3
  • 12
    • 0034992096 scopus 로고    scopus 로고
    • Diagnostic and interventional ultrasonography in neonatal and infant lumbar puncture
    • DOI 10.1007/s002470100453
    • Coley BD, Shiels WE II, Hogan MJ. Diagnostic and interventional ultrasonography in neonatal and infant lumbar puncture. Pediatr Radiol. 2001;31(6):399-402 (Pubitemid 32514772)
    • (2001) Pediatric Radiology , vol.31 , Issue.6 , pp. 399-402
    • Coley, B.D.1    Shiels II, W.E.2    Hogan, M.J.3
  • 13
    • 22944449658 scopus 로고    scopus 로고
    • Ultrasound-guided epidural catheter insertion in children
    • table of contents
    • Rapp HJ, Folger A, Grau T. Ultrasound-guided epidural catheter insertion in children. Anesth Analg. 2005;101(2):333-339, table of contents
    • (2005) Anesth Analg , vol.101 , Issue.2 , pp. 333-339
    • Rapp, H.J.1    Folger, A.2    Grau, T.3
  • 14
    • 77649174625 scopus 로고    scopus 로고
    • Ultrasound imaging for regional anesthesia in infants, children, and adolescents: A review of current literature and its application in the practice of neuraxial blocks
    • Tsui BC, Suresh S. Ultrasound imaging for regional anesthesia in infants, children, and adolescents: a review of current literature and its application in the practice of neuraxial blocks. Anesthesiology. 2010;112(3):719-728
    • (2010) Anesthesiology , vol.112 , Issue.3 , pp. 719-728
    • Tsui, B.C.1    Suresh, S.2
  • 15
    • 64949106526 scopus 로고    scopus 로고
    • Ultrasound identification of landmarks preceding lumbar puncture: A pilot study
    • Ferre RM, Sweeney TW, Strout TD. Ultrasound identification of landmarks preceding lumbar puncture: a pilot study. Emerg Med J. 2009;26(4):276-277
    • (2009) Emerg Med J , vol.26 , Issue.4 , pp. 276-277
    • Ferre, R.M.1    Sweeney, T.W.2    Strout, T.D.3
  • 16
    • 70149113077 scopus 로고    scopus 로고
    • R Development Core Team. Vienna, Austria: R Foundation for Statistical Computing; Available at
    • R Development Core Team. R: A Language and Environment for Statistical Computing. Vienna, Austria: R Foundation for Statistical Computing; 2009, 2010. Available at: www.rproject. org
    • (2009) R: A Language and Environment for Statistical Computing
  • 17
    • 0029685959 scopus 로고    scopus 로고
    • Comparison of 25 G and 29 G Quincke spinal needles in paediatric day case surgery. A prospective randomized study of the puncture characteristics, success rate and postoperative complaints
    • Kokki H, Hendolin H. Comparison of 25 G and 29 G Quincke spinal needles in paediatric day case surgery: a prospective randomized study of the puncture characteristics, success rate and postoperative complaints. Paediatr Anaesth. 1996;6(2):115-119 (Pubitemid 126439106)
    • (1996) Paediatric Anaesthesia , vol.6 , Issue.2 , pp. 115-119
    • Kokki, H.1    Hendolin, H.2
  • 18
    • 0033950276 scopus 로고    scopus 로고
    • Needle design does not affect the success rate of spinal anaesthesia or the incidence of postpuncture complications in children
    • DOI 10.1034/j.1399-6576.2000.440213.x
    • Kokki H, Heikkinen M, Turunen M, Vanamo K, Hendolin H. Needle design does not affect the success rate of spinal anaesthesia or the incidence of postpuncture complications in children. Acta Anaesthesiol Scand. 2000;44(2):210-213 (Pubitemid 30090271)
    • (2000) Acta Anaesthesiologica Scandinavica , vol.44 , Issue.2 , pp. 210-213
    • Kokki, H.1    Heikkinen, M.2    Turunen, M.3    Vanamo, K.4    Hendolin, H.5
  • 19
    • 33847612401 scopus 로고    scopus 로고
    • Prepuncture Ultrasound-Measured Distance: An Accurate Reflection of Epidural Depth in Infants and Small Children
    • DOI 10.1016/j.rapm.2006.10.005, PII S1098733906005670
    • Kil HK, Cho JE, Kim WO, Koo BN, Han SW, Kim JY. Prepuncture ultrasound-measured distance: an accurate reflection of epidural depth in infants and small children. Reg Anesth Pain Med. 2007;32(2):102-106 (Pubitemid 46366777)
    • (2007) Regional Anesthesia and Pain Medicine , vol.32 , Issue.2 , pp. 102-106
    • Kil, H.K.1    Cho, J.E.2    Kim, W.O.3    Koo, B.N.4    Han, S.W.5    Kim, J.Y.6
  • 20
    • 33947132685 scopus 로고    scopus 로고
    • Novel applications of ultrasound in pediatric emergency medicine
    • Chen L, Baker MD. Novel applications of ultrasound in pediatric emergency medicine. Pediatr Emerg Care. 2007;23(2):115-123
    • (2007) Pediatr Emerg Care , vol.23 , Issue.2 , pp. 115-123
    • Chen, L.1    Baker, M.D.2
  • 21
    • 79953299479 scopus 로고    scopus 로고
    • Focus On: Ultrasound Guided Lumbar Puncture
    • Sept
    • Murphy M, Nagdev A. Focus On: Ultrasound Guided Lumbar Puncture. ACEP News. 2007; Sept:23-25
    • (2007) ACEP News , pp. 23-25
    • Murphy, M.1    Nagdev, A.2
  • 23
    • 77953312273 scopus 로고    scopus 로고
    • Accurate prediction of the needle depth required for successful lumbar puncture
    • Chong SY, Chong LA, Ariffin H. Accurate prediction of the needle depth required for successful lumbar puncture. Am J Emerg Med. 2010;28(5):603-606
    • (2010) Am J Emerg Med , vol.28 , Issue.5 , pp. 603-606
    • Chong, S.Y.1    Chong, L.A.2    Ariffin, H.3