Volumn 132, Issue 4, 2010, Pages

Assessment of solar power tower driven ultrasupercritical steam cycles applying tubular central receivers with varied heat transfer media

Author keywords

[No Author keywords available]

Indexed keywords

AMBIENT TEMPERATURES; ANALYTICAL MODEL; DESIGN POINTS; DIRECT NORMAL IRRADIANCES; EFFICIENCY CHARACTERISTIC; HEAT TRANSFER MEDIA; HIGH TEMPERATURE HEAT TRANSFER; IRRADIATION LEVELS; LEC; LEVELIZED ELECTRICITY COST; MOLTEN SALT; OPTIMAL VALUES; PARAMETRIC STUDY; PERFORMANCE BASED; POWER LEVELS; REAL MEASUREMENTS; REDUCTION POTENTIAL; ROADMAP; SCALE-UP; SOLAR POWER TOWER; SOLAR THERMAL; SPECIFIC COST; STATE OF THE ART; STEAM CYCLES; STORAGE CAPACITY; THERMAL EFFICIENCY; THERMAL STORAGE;

EID: 79953253834     PISSN: 01996231     EISSN: 15288986     Source Type: Journal    
DOI: 10.1115/1.4002137     Document Type: Article
Times cited : (72)

References (17)
  • 3
    • 33646087419 scopus 로고    scopus 로고
    • High-efficiency coal-fired power plants development and perspectives
    • Bugge, J., Kjaer, S., and Blum, R., 2006, "High-Efficiency Coal-Fired Power Plants Development and Perspectives," Energy, 31(10-11), pp. 1437-1445.
    • (2006) Energy , vol.31 , Issue.10-11 , pp. 1437-1445
    • Bugge, J.1    Kjaer, S.2    Blum, R.3
  • 4
    • 77953770395 scopus 로고    scopus 로고
    • Sandia National Laboratories
    • Sandia National Laboratories, 1998, "Solar Tower Power," http:// www.energylan.sandia.gov/sunlab/PDFs/solar-tower.pdf
    • (1998) Solar Tower Power
  • 6
    • 45249105740 scopus 로고    scopus 로고
    • High flux central receivers of molten salts for the new generation of commercial stand-alone solar power plants
    • Lata, J. M., Rodriguez, M., and De Lara, M. A., 2008, "High Flux Central Receivers of Molten Salts for the New Generation of Commercial Stand-Alone Solar Power Plants," ASME J. Sol. Energy Eng., 130(2), p. 021002.
    • (2008) ASME J. Sol. Energy Eng. , vol.130 , Issue.2 , pp. 021002
    • Lata, J.M.1    Rodriguez, M.2    De Lara, M.A.3
  • 10
    • 77953904071 scopus 로고    scopus 로고
    • S. N. Laboratories, Paper No. SAND2001-2100, TRN: AH200132%%389, United States Department of Energy
    • Zavoico, A. B., 2001, "Solar Power Tower Design Basis Document," S. N. Laboratories, Paper No. SAND2001-2100, TRN: AH200132%%389, United States Department of Energy.
    • (2001) Solar Power Tower Design Basis Document
    • Zavoico, A.B.1
  • 13
    • 13144250462 scopus 로고    scopus 로고
    • Mannsville Chemical Products Corp
    • Mannsville Chemical Products Corp., 1999, "Chemical Products Synopsis- Sodium," http://www.mannsvillechemical.com/synopsis/report.html
    • (1999) Chemical Products Synopsis- Sodium
  • 14
    • 77953795084 scopus 로고    scopus 로고
    • London Metal Exchange
    • London Metal Exchange, 2007, "Tin Price Graph," http://www.lme.co.uk/ tin-graphs.asp
    • (2007) Tin Price Graph
  • 15
    • 33845802503 scopus 로고    scopus 로고
    • Assessment of candidate molten salt coolants for the NGNP/NHI heat-transfer loop
    • Williams, D. F., 2006, "Assessment of Candidate Molten Salt Coolants for the NGNP/NHI Heat-Transfer Loop," ORNL, TM-2006(69), pp. 13-21.
    • (2006) ORNL , vol.TM-2006 , Issue.69 , pp. 13-21
    • Williams, D.F.1
  • 16
    • 45249097340 scopus 로고    scopus 로고
    • Central receiver system solar power plant using molten salt as heat transfer fluid
    • Ortega, J. I., Burgaleta, J. I., and Tellez, F. M., 2008, "Central Receiver System Solar Power Plant Using Molten Salt as Heat Transfer Fluid," ASME J. Sol. Energy Eng., 130(2), p. 024501.
    • (2008) ASME J. Sol. Energy Eng. , vol.130 , Issue.2 , pp. 024501
    • Ortega, J.I.1    Burgaleta, J.I.2    Tellez, F.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.