메뉴 건너뛰기




Volumn 33, Issue 4, 2011, Pages 908-915

Imaging of the wrist at 1.5 Tesla using isotropic three-dimensional fast spin echo cube

Author keywords

3D FSE cube; Isotropic; MRI; Wrist

Indexed keywords

ADULT; ARTICLE; ARTICULAR CARTILAGE; COMPARATIVE ANATOMY; COMPARATIVE EFFECTIVENESS; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; JOINT RADIOGRAPHY; MUSCLE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SYNOVIAL FLUID; THREE DIMENSIONAL FAST SPIN ECHO CUBE; TWO DIMENSIONAL FAST SPIN ECHO CUBE; WRIST;

EID: 79953241701     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22494     Document Type: Article
Times cited : (42)

References (40)
  • 1
    • 2442563391 scopus 로고    scopus 로고
    • An anatomical study of the ligaments of the ulnar compartment of the wrist
    • Sasao S, Beppu M, Kihara H, Hirata K, Takagi M. An anatomical study of the ligaments of the ulnar compartment of the wrist. Hand Surg 2003;8:219-226.
    • (2003) Hand Surg , vol.8 , pp. 219-226
    • Sasao, S.1    Beppu, M.2    Kihara, H.3    Hirata, K.4    Takagi, M.5
  • 3
    • 0142062525 scopus 로고    scopus 로고
    • High-resolution MR imaging of triangular fibrocartilage complex (TFCC): Comparison of microscopy coils and a conventional small surface coil
    • DOI 10.1007/s00256-003-0672-7
    • Yoshioka H, Ueno T, Tanaka T, Shindo M, Itai Y. High-resolution MR imaging of triangular fibrocartilage complex (TFCC): comparison of microscopy coils and a conventional small surface coil. Skeletal Radiol 2003;32:575-581. (Pubitemid 37265281)
    • (2003) Skeletal Radiology , vol.32 , Issue.10 , pp. 575-581
    • Yoshioka, H.1    Ueno, T.2    Tanaka, T.3    Shindo, M.4    Itai, Y.5
  • 4
    • 2542589289 scopus 로고    scopus 로고
    • MR imaging of ligaments and triangular fibrocartilage complex of the wrist
    • Zlatkin MB, Rosner J. MR imaging of ligaments and triangular fibrocartilage complex of the wrist. Magn Reson Imaging Clin N Am 2004;12:301-331, vi-vii.
    • (2004) Magn Reson Imaging Clin N Am , vol.12
    • Zlatkin, M.B.1    Rosner, J.2
  • 5
    • 50249134927 scopus 로고    scopus 로고
    • Diagnostic comparison of 1.5 Tesla and 3.0 Tesla preoperative MRI of the wrist in patients with ulnar-sided wrist pain
    • Anderson ML, Skinner JA, Felmlee JP, Berger RA, Amrami KK. Diagnostic comparison of 1.5 Tesla and 3.0 Tesla preoperative MRI of the wrist in patients with ulnar-sided wrist pain. J Hand Surg [Am] 2008;33:1153-1159.
    • (2008) J Hand Surg [Am] , vol.33 , pp. 1153-1159
    • Anderson, M.L.1    Skinner, J.A.2    Felmlee, J.P.3    Berger, R.A.4    Amrami, K.K.5
  • 10
    • 58149252144 scopus 로고    scopus 로고
    • Comparison of 3-T MRI and arthroscopy of intrinsic wrist ligament and TFCC tears
    • Magee T. Comparison of 3-T MRI and arthroscopy of intrinsic wrist ligament and TFCC tears. AJR Am J Roentgenol 2009;192:80-85.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 80-85
    • Magee, T.1
  • 11
    • 63749108769 scopus 로고    scopus 로고
    • 3-Tesla high-resolution MR imaging of the wrist
    • Saupe N. 3-Tesla high-resolution MR imaging of the wrist. Semin Musculoskelet Radiol 2009;13:29-38.
    • (2009) Semin Musculoskelet Radiol , vol.13 , pp. 29-38
    • Saupe, N.1
  • 13
    • 46249100405 scopus 로고    scopus 로고
    • Comparison of MRI and wrist arthroscopy for assessment of wrist cartilage
    • DOI 10.1177/1753193408090395
    • Mutimer J, Green J, Field J. Comparison of MRI and wrist arthroscopy for assessment of wrist cartilage. J Hand Surg Eur 2008;33:380-382. (Pubitemid 351911221)
    • (2008) Journal of Hand Surgery: European Volume , vol.33 , Issue.3 , pp. 380-382
    • Mutimer, J.1    Green, J.2    Field, J.3
  • 14
    • 34147222722 scopus 로고    scopus 로고
    • MR imaging of cartilage in cadaveric wrists: Comparison between imaging at 1.5 and 3.0 T and gross pathologic inspection
    • DOI 10.1148/radiol.2431060294
    • Saupe N, Pfirrmann CW, Schmid MR, Schertler T, Manestar M, Weishaupt D. MR imaging of cartilage in cadaveric wrists: comparison between imaging at 1.5 and 3.0 T and gross pathologic inspection. Radiology 2007;243:180-187. (Pubitemid 46579709)
    • (2007) Radiology , vol.243 , Issue.1 , pp. 180-187
    • Saupe, N.1    Pfirrmann, C.W.A.2    Schmid, M.R.3    Schertler, T.4    Manestar, M.5    Weishaupt, D.6
  • 15
    • 34247631007 scopus 로고    scopus 로고
    • Wrist ligament tears: Evaluation of MRI and combined MDCT and MR arthrography
    • DOI 10.2214/AJR.06.0288
    • Moser T, Dosch JC, Moussaoui A, Dietemann JL. Wrist ligament tears: evaluation of MRI and combined MDCT and MR arthrography. AJR Am J Roentgenol 2007;188:1278-1286. (Pubitemid 46668509)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.5 , pp. 1278-1286
    • Moser, T.1    Dosch, J.-C.2    Moussaoui, A.3    Dietemann, J.-L.4
  • 16
  • 19
    • 64949151539 scopus 로고    scopus 로고
    • Vastly undersampled isotropic projection steady-state free precession imaging of the knee: Diagnostic performance compared with conventional MR
    • Kijowski R, Blankenbaker DG, Klaers JL, Shinki K, De Smet AA, Block WF. Vastly undersampled isotropic projection steady-state free precession imaging of the knee: diagnostic performance compared with conventional MR. Radiology 2009;251:185-194.
    • (2009) Radiology , vol.251 , pp. 185-194
    • Kijowski, R.1    Blankenbaker, D.G.2    Klaers, J.L.3    Shinki, K.4    De Smet, A.A.5    Block, W.F.6
  • 20
    • 64249163122 scopus 로고    scopus 로고
    • Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee-image quality and diagnostic performance
    • Ristow O, Steinbach L, Sabo G, et al. Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee-image quality and diagnostic performance. Eur Radiol 2009;19:1263-1272.
    • (2009) Eur Radiol , vol.19 , pp. 1263-1272
    • Ristow, O.1    Steinbach, L.2    Sabo, G.3
  • 22
    • 58149196705 scopus 로고    scopus 로고
    • Ankle: Isotropic MR imaging with 3D-FSE-cube--initial experience in healthy volunteers
    • Stevens KJ, Busse RF, Han E, et al. Ankle: isotropic MR imaging with 3D-FSE-cube--initial experience in healthy volunteers. Radiology 2008;249:1026-1033.
    • (2008) Radiology , vol.249 , pp. 1026-1033
    • Stevens, K.J.1    Busse, R.F.2    Han, E.3
  • 23
    • 61749102823 scopus 로고    scopus 로고
    • Three-dimensional isotropic shoulder MR arthrography: Comparison with two-dimensional MR arthrography for the diagnosis of labral lesions at 3.0 T
    • Jung JY, Yoon YC, Choi SH, Kwon JW, Yoo J, Choe BK. Three-dimensional isotropic shoulder MR arthrography: comparison with two-dimensional MR arthrography for the diagnosis of labral lesions at 3.0 T. Radiology 2009;250:498-505.
    • (2009) Radiology , vol.250 , pp. 498-505
    • Jung, J.Y.1    Yoon, Y.C.2    Choi, S.H.3    Kwon, J.W.4    Yoo, J.5    Choe, B.K.6
  • 24
    • 59349091667 scopus 로고    scopus 로고
    • Comparison of indirect isotropic MR arthrography and conventional MR arthrography of labral lesions and rotator cuff tears: A prospective study
    • Oh DK, Yoon YC, Kwon JW, et al. Comparison of indirect isotropic MR arthrography and conventional MR arthrography of labral lesions and rotator cuff tears: a prospective study. AJR Am J Roentgenol 2009;192:473-479.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 473-479
    • Oh, D.K.1    Yoon, Y.C.2    Kwon, J.W.3
  • 25
    • 38949120094 scopus 로고    scopus 로고
    • Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
    • DOI 10.1002/mrm.21481
    • Brau AC, Beatty PJ, Skare S, Bammer R. Comparison of reconstruction accuracy and efficiency among autocalibrating datadriven parallel imaging methods. Magn Reson Med 2008;59:382-395. (Pubitemid 351220102)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.2 , pp. 382-395
    • Brau, A.C.S.1    Beatty, P.J.2    Skare, S.3    Bammer, R.4
  • 27
    • 33749429008 scopus 로고    scopus 로고
    • Comparison between High-Resolution MRI with a Microscopy Coil and Arthroscopy in Triangular Fibrocartilage Complex Injury
    • DOI 10.1016/j.jhsa.2006.05.001, PII S0363502306005600
    • Tanaka T, Yoshioka H, Ueno T, Shindo M, Ochiai N. Comparison between high-resolution MRI with a microscopy coil and arthroscopy in triangular fibrocartilage complex injury. J Hand Surg [Am] 2006;31:1308-1314. (Pubitemid 44508792)
    • (2006) Journal of Hand Surgery , vol.31 , Issue.8 , pp. 1308-1314
    • Tanaka, T.1    Yoshioka, H.2    Ueno, T.3    Shindo, M.4    Ochiai, N.5
  • 28
    • 10644224415 scopus 로고    scopus 로고
    • MR imaging of the wrist: Comparison between 1.5-and 3-T MR imaging - Preliminary experience
    • DOI 10.1148/radiol.2341031596
    • Saupe N, Prussmann KP, Luechinger R, Bosiger P, Marincek B, Weishaupt D. MR imaging of the wrist: comparison between 1.5- and 3-T MR imaging--preliminary experience. Radiology 2005;234:256-264. (Pubitemid 39658394)
    • (2005) Radiology , vol.234 , Issue.1 , pp. 256-264
    • Saupe, N.1    Prussmann, K.P.2    Luechinger, R.3    Bosiger, P.4    Marincek, B.5    Weishaupt, D.6
  • 29
    • 33847307682 scopus 로고    scopus 로고
    • Evaluation of the triangular fibrocartilage in cadaveric wrists by means of arthrography, Magnetic Resonance (MR) imaging, and MR arthrography
    • DOI 10.1080/02841850601045112, PII 771214434
    • Berna-Serna JD, Martinez F, Reus M, Alonso J, Domenech G, Campos M. Evaluation of the triangular fibrocartilage in cadaveric wrists by means of arthrography, magnetic resonance (MR) imaging, and MR arthrography. Acta Radiol 2007;48:96-103. (Pubitemid 46324042)
    • (2007) Acta Radiologica , vol.48 , Issue.1 , pp. 96-103
    • Berna-Serna, J.D.1    Martinez, F.2    Reus, M.3    Alonso, J.4    Domenech, G.5    Campos, M.6
  • 30
    • 33845777092 scopus 로고    scopus 로고
    • Peripheral tear of the triangular fibrocartilage: Depiction with MR arthrography of the distal radioulnar joint
    • DOI 10.2214/AJR.05.2056
    • Ruegger C, Schmid MR, Pfirrmann CW, Nagy L, Gilula LA, Zanetti M. Peripheral tear of the triangular fibrocartilage: depiction with MR arthrography of the distal radioulnar joint. AJR Am J Roentgenol 2007;188:187-192. (Pubitemid 46012507)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.1 , pp. 187-192
    • Ruegger, C.1    Schmid, M.R.2    Pfirrmann, C.W.A.3    Nagy, L.4    Gilula, L.A.5    Zanetti, M.6
  • 31
    • 0031401283 scopus 로고    scopus 로고
    • Triangular fibrocartilage and intercarpal ligaments of the wrist: Does MR arthrography improve standard MRI?
    • Zanetti M, Bram J, Hodler J. Triangular fibrocartilage and intercarpal ligaments of the wrist: does MR arthrography improve standard MRI? J Magn Reson Imaging 1997;7:590-594.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 590-594
    • Zanetti, M.1    Bram, J.2    Hodler, J.3
  • 32
    • 62749199734 scopus 로고    scopus 로고
    • MR Arthrography of the wrist: Controversies and concepts
    • Maizlin ZV, Brown JA, Clement JJ, et al. MR Arthrography of the wrist: controversies and concepts. Hand (N Y) 2009;4:66-73.
    • (2009) Hand (N Y) , vol.4 , pp. 66-73
    • Maizlin, Z.V.1    Brown, J.A.2    Clement, J.J.3
  • 33
    • 0032929424 scopus 로고    scopus 로고
    • The carpal ligaments in MR arthrography of the wrist: Correlation with standard MRI and wrist arthroscopy
    • DOI 10.1002/(SICI)1522-2586(199903)9:3<468::AID-JMRI16>3.0.CO;2-T
    • Scheck RJ, Romagnolo A, Hierner R, Pfluger T, Wilhelm K, Hahn K. The carpal ligaments in MR arthrography of the wrist: correlation with standard MRI and wrist arthroscopy. J Magn Reson Imaging 1999;9:468-474. (Pubitemid 29180143)
    • (1999) Journal of Magnetic Resonance Imaging , vol.9 , Issue.3 , pp. 468-474
    • Scheck, R.J.1    Romagnolo, A.2    Hierner, R.3    Pfluger, T.4    Wilhelm, K.5    Hahn, K.6
  • 34
    • 33646449765 scopus 로고    scopus 로고
    • Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast
    • Busse RF, Hariharan H, Vu A, Brittain JH. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magn Reson Med 2006;55:1030-1037.
    • (2006) Magn Reson Med , vol.55 , pp. 1030-1037
    • Busse, R.F.1    Hariharan, H.2    Vu, A.3    Brittain, J.H.4
  • 35
    • 33845252291 scopus 로고    scopus 로고
    • 2D partially parallel imaging with K-space surrounding neighbors-based data reconstruction
    • DOI 10.1002/mrm.21078
    • Wang Z, Fernandez-Seara MA. 2D partially parallel imaging with k-space surrounding neighbors-based data reconstruction. Magn Reson Med 2006;56:1389-1396. (Pubitemid 44865325)
    • (2006) Magnetic Resonance in Medicine , vol.56 , Issue.6 , pp. 1389-1396
    • Wang, Z.1    Fernandez-Seara, M.A.2
  • 38
    • 38949120094 scopus 로고    scopus 로고
    • Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
    • DOI 10.1002/mrm.21481
    • Brau ACS, Beatty PJ, Skare S, Bammer R. Comparison of computational accuracy and efficiency in autocalibrating parallel imaging reconstructions. Magn Reson Med 2008;59:382-395. (Pubitemid 351220102)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.2 , pp. 382-395
    • Brau, A.C.S.1    Beatty, P.J.2    Skare, S.3    Bammer, R.4
  • 39
    • 51449085600 scopus 로고    scopus 로고
    • Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    • Busse RF, Brau AC, Vu A, et al. Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 2008;60:640-649.
    • (2008) Magn Reson Med , vol.60 , pp. 640-649
    • Busse, R.F.1    Brau, A.C.2    Vu, A.3
  • 40
    • 38949156006 scopus 로고    scopus 로고
    • A method for autocalibrating 2D-accelerated volumetric parallel imaging with clinically practical reconstruction times
    • abstract 1749
    • Beatty P, Brau ACS, Chang S, et al. A method for autocalibrating 2D-accelerated volumetric parallel imaging with clinically practical reconstruction times. In: Proceedings of the 15th Annual meeting of ISMRM, Berlin, 2007. (abstract 1749).
    • Proceedings of the 15th Annual Meeting of ISMRM, Berlin, 2007
    • Beatty, P.1    Brau, A.C.S.2    Chang, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.