Volumn 21, Issue 3, 2011, Pages 484-497

Optimal serial dilutions designs for drug discovery experiments

Author keywords

Bioassay; Dose response study; High throughput screening; Minimum significant difference; Population D and DS optimality

Indexed keywords

ARTICLE; COST EFFECTIVENESS ANALYSIS; DILUTION; DOSE RESPONSE; DRUG DETERMINATION; DRUG DEVELOPMENT; DRUG POTENCY; EXPERIMENTAL DESIGN; IC 50; MAXIMUM PERMISSIBLE DOSE; PRIORITY JOURNAL;

EID: 79953224121     PISSN: 10543406     EISSN: 15205711     Source Type: Journal    
DOI: 10.1080/10543406.2010.481801     Document Type: Article
Times cited : (2)

References (15)
  • 5
    • 33646272448 scopus 로고    scopus 로고
    • The minimum significant ratio: A statistical parameter to characterize the reproducibility of potency estimates from concentrationresponse assays and estimation by replicate-experiment studies
    • Eastwood, B. J., Farmen, M. W., Iversen, P. W., Craft, T. J., Smallwood, J. K., Garbison, K. E., Delapp, N. W., Smith, G. F. (2006). The minimum significant ratio: a statistical parameter to characterize the reproducibility of potency estimates from concentrationresponse assays and estimation by replicate-experiment studies. Journal of Biological Screening 11:253-261
    • (2006) Journal of Biological Screening , vol.11 , pp. 253-261
    • Eastwood, B.J.1    Farmen, M.W.2    Iversen, P.W.3    Craft, T.J.4    Smallwood, J.K.5    Garbison, K.E.6    Delapp, N.W.7    Smith, G.F.8
  • 8
    • 0001145764 scopus 로고
    • The combinations of haemoglobin with oxygen and with carbon monoxide
    • Hill, A. V. (1913). The combinations of haemoglobin with oxygen and with carbon monoxide. Biochem. J. 7:471-480.
    • (1913) Biochem. J. , vol.7 , pp. 471-480
    • Hill, A.V.1
  • 9
    • 0032738752 scopus 로고    scopus 로고
    • Statistical inference for serial dilution assay data
    • Lee, M.-L. T., Whitmore, G. A. (1999). Statistical inference for serial dilution assay data. Biometrics 55:1215-1220
    • (1999) Biometrics , vol.55 , pp. 1215-1220
    • Lee, M.-L.T.1    Whitmore, G.A.2
  • 10
    • 0032899688 scopus 로고    scopus 로고
    • Design and analysis of serial limiting dilution assays with small sample sizes
    • DOI 10.1016/S0022-1759(98)00133-1, PII S0022175998001331
    • Macken, C. (1999). Design and analysis of serial limiting dilution assays with small sample sizes. Journal of Immunological Methods 222:13-29 (Pubitemid 29023699)
    • (1999) Journal of Immunological Methods , vol.222 , Issue.1-2 , pp. 13-29
    • MacKen, C.1
  • 11
    • 0032417679 scopus 로고    scopus 로고
    • Implementable Bayesian designs for limiting dilution assays
    • DOI 10.2307/2533666
    • Mehrabi, Y., Matthews, J. N. S. (1998). Implementable Bayesian designs for limiting dilution assays. Biometrics 54:1398-1406 (Pubitemid 29018623)
    • (1998) Biometrics , vol.54 , Issue.4 , pp. 1398-1406
    • Mehrabi, Y.1    Matthews, J.N.S.2
  • 12
    • 0008190079 scopus 로고    scopus 로고
    • Development of high throughput screening assays using fluorescence polarization: Nuclear receptor-ligand-binding and kinase/phosphatase assays
    • Parker, G. J., Law, T. L., Lenoch, F. J., Bolger, R. E. (2000). Development of high throughput screening assays using fluorescence polarization: nuclear receptor-ligand binding and kinase/phosphatase assays. Journal of Biomolecular Screening 5:77-88 (Pubitemid 30243877)
    • (2000) Journal of Biomolecular Screening , vol.5 , Issue.2 , pp. 77-88
    • Parker, G.J.1    Law, T.L.2    Lenoch, F.J.3    Bolger, R.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.