메뉴 건너뛰기




Volumn 41, Issue 3, 2011, Pages 229-241

Breast cancer imaging devices

Author keywords

[No Author keywords available]

Indexed keywords

CERIUM; LUTETIUM; SILICATE; SODIUM IODIDE; YTTRIUM; YTTRIUM 90;

EID: 79953221149     PISSN: 00012998     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.semnuclmed.2010.12.005     Document Type: Review
Times cited : (44)

References (53)
  • 1
    • 77956869636 scopus 로고    scopus 로고
    • Positive predictive value of mammography: Comparison of interpretations of screening and diagnostic images by the same radiologist and by different radiologists
    • J.R. Halladay, B.C. Yankaskas, and J.M. Bowling Positive predictive value of mammography: Comparison of interpretations of screening and diagnostic images by the same radiologist and by different radiologists AJR Am J Roentgenol 195 2010 782 785
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 782-785
    • Halladay, J.R.1    Yankaskas, B.C.2    Bowling, J.M.3
  • 2
    • 79951860891 scopus 로고    scopus 로고
    • BRCA1-associated breast cancers present differently from BRCA2-associated and familial cases: Long-term follow-up of the Dutch MRISC screening study
    • A.J. Rijnsburger, I.M. Obdeijn, and R. Kaas BRCA1-associated breast cancers present differently from BRCA2-associated and familial cases: Long-term follow-up of the Dutch MRISC screening study J Clin Oncol 28 2010 5265 5273
    • (2010) J Clin Oncol , vol.28 , pp. 5265-5273
    • Rijnsburger, A.J.1    Obdeijn, I.M.2    Kaas, R.3
  • 3
    • 49249112188 scopus 로고    scopus 로고
    • Accuracy and surgical impact of magnetic resonance imaging in breast cancer staging: Systematic review and meta-analysis in detection of multifocal and multicentric cancer
    • N. Houssami, S. Ciatto, and P. Macaskill Accuracy and surgical impact of magnetic resonance imaging in breast cancer staging: Systematic review and meta-analysis in detection of multifocal and multicentric cancer J Clin Oncol 26 2008 3248 3258
    • (2008) J Clin Oncol , vol.26 , pp. 3248-3258
    • Houssami, N.1    Ciatto, S.2    MacAskill, P.3
  • 4
    • 75349104287 scopus 로고    scopus 로고
    • Reasons women at elevated risk of breast cancer refuse breast MR imaging screening: ACRIN 6666
    • W.A. Berg, J.D. Blume, and A.M. Adams Reasons women at elevated risk of breast cancer refuse breast MR imaging screening: ACRIN 6666 Radiology 254 2010 79 87
    • (2010) Radiology , vol.254 , pp. 79-87
    • Berg, W.A.1    Blume, J.D.2    Adams, A.M.3
  • 5
    • 0027279806 scopus 로고
    • Imaging of the radiographically dense breast
    • V.P. Jackson, R.E. Hendrick, and S.A. Feig Imaging of the radiographically dense breast Radiology 188 1993 297 301 (Pubitemid 23216242)
    • (1993) Radiology , vol.188 , Issue.2 , pp. 297-301
    • Jackson, V.P.1    Hendrick, R.E.2    Feig, S.A.3    Kopans, D.B.4
  • 7
    • 77957331968 scopus 로고    scopus 로고
    • Radiation doses and cancer risks from breast imaging studies
    • R.E. Hendrick Radiation doses and cancer risks from breast imaging studies Radiology 257 2010 246 253
    • (2010) Radiology , vol.257 , pp. 246-253
    • Hendrick, R.E.1
  • 8
    • 78650611558 scopus 로고    scopus 로고
    • Dedicated dual-head gamma imaging for breast cancer screening in women with mammographically dense breasts
    • D.J. Rhodes, C.B. Hruska, and S.W. Phillips Dedicated dual-head gamma imaging for breast cancer screening in women with mammographically dense breasts Radiology 258 2011 106 118
    • (2011) Radiology , vol.258 , pp. 106-118
    • Rhodes, D.J.1    Hruska, C.B.2    Phillips, S.W.3
  • 9
    • 78149347499 scopus 로고
    • National Cancer Institute Bethesda, MD
    • S.F. Altekruse, C.L. Kosary, and M. Krapcho SEER Cancer Statistics Review 1975-2007 National Cancer Institute Bethesda, MD http://seer.cancer.gov/csr/ 1975-2007/ based on 2009 SEER data submission, posted to the SEER web site, 2010
    • (1975) SEER Cancer Statistics Review
    • Altekruse, S.F.1    Kosary, C.L.2    Krapcho, M.3
  • 10
    • 0034667846 scopus 로고    scopus 로고
    • Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose: Use and limitations
    • N. Avril, C.A. Ros, and M. Schelling Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose: Use and limitations J Clin Oncol 18 2000 3495 3502
    • (2000) J Clin Oncol , vol.18 , pp. 3495-3502
    • Avril, N.1    Ros, C.A.2    Schelling, M.3
  • 11
    • 70349644006 scopus 로고    scopus 로고
    • Clinical imaging characteristics of the positron emission mammography camera: PEM Flex Solo II
    • L. MacDonald, J. Edwards, and T. Lewellen Clinical imaging characteristics of the positron emission mammography camera: PEM Flex Solo II J Nucl Med 50 2009 1666 1675
    • (2009) J Nucl Med , vol.50 , pp. 1666-1675
    • MacDonald, L.1    Edwards, J.2    Lewellen, T.3
  • 13
    • 58049218961 scopus 로고    scopus 로고
    • Experimental characterization of the 192 channel Clear-PEM fronted ASIC coupled to a multi-pixel APD read out of LYSO: Ce crystals
    • E. Albuquerque, V. Bexiga, and R. Bugalho Experimental characterization of the 192 channel Clear-PEM fronted ASIC coupled to a multi-pixel APD read out of LYSO: Ce crystals Nucl Instruments Methods Phys Res A 598 2009 802 814
    • (2009) Nucl Instruments Methods Phys Res A , vol.598 , pp. 802-814
    • Albuquerque, E.1    Bexiga, V.2    Bugalho, R.3
  • 14
    • 79251596431 scopus 로고    scopus 로고
    • The ClearPEM breast imaging scanner
    • J.A. Neves The ClearPEM breast imaging scanner Nucl Instr Meth A 628 2011 444 447
    • (2011) Nucl Instr Meth A , vol.628 , pp. 444-447
    • Neves, J.A.1
  • 16
    • 77951197498 scopus 로고    scopus 로고
    • Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors
    • H. Peng, and C.S. Levin Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors Phys Med Biol 55 2010 2761 2788
    • (2010) Phys Med Biol , vol.55 , pp. 2761-2788
    • Peng, H.1    Levin, C.S.2
  • 17
    • 77957718627 scopus 로고    scopus 로고
    • Performance characterization of a new high resolution PET scintillation detector
    • A. Vandenbroucke, A.M. Foudray, and P.D. Olcott Performance characterization of a new high resolution PET scintillation detector Phys Med Biol 55 2010 5895 5911
    • (2010) Phys Med Biol , vol.55 , pp. 5895-5911
    • Vandenbroucke, A.1    Foudray, A.M.2    Olcott, P.D.3
  • 18
    • 79954416508 scopus 로고    scopus 로고
    • Silicon photomultipliers for positron emission tomography detectors with depth of interaction encoding capability
    • (in press)
    • Taghibakhsh F, Reznik A, Rowlands JA: Silicon photomultipliers for positron emission tomography detectors with depth of interaction encoding capability. Nucl Instr Meth A (in press)
    • Nucl Instr Meth A
    • Taghibakhsh, F.1    Reznik, A.2    Rowlands, J.A.3
  • 19
    • 79551531671 scopus 로고    scopus 로고
    • Positron emission mammography in breast cancer presurgical planning: Comparisons with magnetic resonance imaging
    • K. Schilling, D. Narayanan, and J.E. Kalinyak Positron emission mammography in breast cancer presurgical planning: Comparisons with magnetic resonance imaging Eur J Nucl Med Mol Imaging 38 2010 23 36
    • (2010) Eur J Nucl Med Mol Imaging , vol.38 , pp. 23-36
    • Schilling, K.1    Narayanan, D.2    Kalinyak, J.E.3
  • 20
    • 78650607448 scopus 로고    scopus 로고
    • Breast cancer: Comparative Effectiveness of positron emission mammography and MR imaging in presurgical planning for the ipsilateral breast
    • W.A. Berg, K.S. Madsen, and K. Schilling Breast cancer: Comparative Effectiveness of positron emission mammography and MR imaging in presurgical planning for the ipsilateral breast Radiology 258 2010 59 72
    • (2010) Radiology , vol.258 , pp. 59-72
    • Berg, W.A.1    Madsen, K.S.2    Schilling, K.3
  • 21
    • 0037823138 scopus 로고    scopus 로고
    • Breast cancer diagnosis by scintimammography: A meta-analysis and review of the literature
    • DOI 10.1023/A:1024417331304
    • M. Liberman, F. Sampalis, and D.S. Mulder Breast cancer diagnosis by scintimammography: A meta-analysis and review of the literature Breast Cancer Res Treat 80 2003 115 126 (Pubitemid 36851291)
    • (2003) Breast Cancer Research and Treatment , vol.80 , Issue.1 , pp. 115-126
    • Liberman, M.1    Sampalis, F.2    Mulder, D.S.3    Sampalis, J.S.4
  • 22
    • 73249119834 scopus 로고    scopus 로고
    • Breast-specific gamma-imaging: Molecular imaging of the breast using 99mTc-sestamibi and a small-field-of-view gamma-camera
    • E.A. Jones, T.D. Phan, and D.A. Blanchard Breast-specific gamma-imaging: Molecular imaging of the breast using 99mTc-sestamibi and a small-field-of-view gamma-camera J Nucl Med Technol 37 2009 201 205
    • (2009) J Nucl Med Technol , vol.37 , pp. 201-205
    • Jones, E.A.1    Phan, T.D.2    Blanchard, D.A.3
  • 24
    • 57149129093 scopus 로고    scopus 로고
    • Molecular breast imaging: Use of a dual-head dedicated gamma camera to detect small breast tumors
    • C.B. Hruska, S.W. Phillips, and D.H. Whaley Molecular breast imaging: Use of a dual-head dedicated gamma camera to detect small breast tumors AJR Am J Roentgenol 191 2008 1805 1815
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1805-1815
    • Hruska, C.B.1    Phillips, S.W.2    Whaley, D.H.3
  • 26
    • 79251618957 scopus 로고    scopus 로고
    • Super Spatial Resolution (SSR) method for scintigraphic imaging
    • G. Trinci, R. Massari, and M. Scandellari Super Spatial Resolution (SSR) method for scintigraphic imaging Nucl Instr Meth A 626 2011 626 627
    • (2011) Nucl Instr Meth A , vol.626 , pp. 626-627
    • Trinci, G.1    Massari, R.2    Scandellari, M.3
  • 27
    • 79959854206 scopus 로고    scopus 로고
    • Investigation of the potential use of LaBr3:Ce scintillators for scintimammography imaging
    • (in press)
    • Alzimami KS, Sassi SA, Alfuraih AA,, et al. Investigation of the potential use of LaBr3:Ce scintillators for scintimammography imaging. Nucl Instr Meth A (in press)
    • Nucl Instr Meth A
    • Alzimami, K.S.1    Sassi, S.A.2    Alfuraih, A.A.3
  • 28
    • 79953213504 scopus 로고    scopus 로고
    • A novel high resolution and high efficiency dual head detector for molecular breast imaging: New results from clinical trials
    • F. Garibaldi, E. Cisbani, and S. Colilli A novel high resolution and high efficiency dual head detector for molecular breast imaging: New results from clinical trials Nuclear Instruments Methods Phys Res A 617 2010 227 229
    • (2010) Nuclear Instruments Methods Phys Res A , vol.617 , pp. 227-229
    • Garibaldi, F.1    Cisbani, E.2    Colilli, S.3
  • 29
    • 79953227892 scopus 로고    scopus 로고
    • New design of a gamma camera detector with reduced edge effect for breast imaging
    • (in press)
    • Yeon Hwang J, Lee S-J, Baek C-H,, et al. New design of a gamma camera detector with reduced edge effect for breast imaging. Nucl Instr Meth A (in press)
    • Nucl Instr Meth A
    • Yeon Hwang, J.1    Lee, S.-J.2    Baek, C.-H.3
  • 30
    • 45149119135 scopus 로고    scopus 로고
    • Mathur V. Breast-specific gamma imaging as an adjunct imaging modality for the diagnosis of breast cancer [Erratum in: Radiology 2009 251(1):308.]
    • R.F. Brem, A.C. Floerke, and J.A. Rapelyea Mathur V. Breast-specific gamma imaging as an adjunct imaging modality for the diagnosis of breast cancer [Erratum in: Radiology 2009 251(1):308.] Radiology 247 2008 651 657
    • (2008) Radiology , vol.247 , pp. 651-657
    • Brem, R.F.1    Floerke, A.C.2    Rapelyea, J.A.3
  • 31
    • 70349456656 scopus 로고    scopus 로고
    • George Peters Award: How does breast-specific gamma imaging affect the management of patients with newly diagnosed breast cancer?
    • B.K. Killelea, A. Gillego, and L.J. Kirstein George Peters Award: How does breast-specific gamma imaging affect the management of patients with newly diagnosed breast cancer? Am J Surg 198 2009 470 474
    • (2009) Am J Surg , vol.198 , pp. 470-474
    • Killelea, B.K.1    Gillego, A.2    Kirstein, L.J.3
  • 33
    • 42049106812 scopus 로고    scopus 로고
    • Real-world application of breast-specific gamma imaging, initial experience at a community breast center and its potential impact on clinical care
    • DOI 10.1016/j.amjsurg.2008.01.006, PII S0002961008001049
    • M. Zhou, N. Johnson, and D. Blanchard Real-world application of breast-specific gamma imaging, initial experience at a community breast center and its potential impact on clinical care Am J Surg 195 2008 631 635 (Pubitemid 351522204)
    • (2008) American Journal of Surgery , vol.195 , Issue.5 , pp. 631-635
    • Zhou, M.1    Johnson, N.2    Blanchard, D.3    Bryn, S.4    Nelson, J.5
  • 37
    • 63449130306 scopus 로고    scopus 로고
    • A prospective study comparing touch imprint cytology, frozen section analysis, and rapid cytokeratin immunostain for intraoperative evaluation of axillary sentinel lymph nodes in breast cancer
    • S. Krishnamurthy, F. Meric-Bernstam, and A. Lucci A prospective study comparing touch imprint cytology, frozen section analysis, and rapid cytokeratin immunostain for intraoperative evaluation of axillary sentinel lymph nodes in breast cancer Cancer 115 2009 1555 1562
    • (2009) Cancer , vol.115 , pp. 1555-1562
    • Krishnamurthy, S.1    Meric-Bernstam, F.2    Lucci, A.3
  • 38
    • 27444433903 scopus 로고    scopus 로고
    • Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature
    • S.C. Kim, D.W. Kim, and R.M. Moadel Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature World J Surg Oncol 3 2005 64
    • (2005) World J Surg Oncol , vol.3 , pp. 64
    • Kim, S.C.1    Kim, D.W.2    Moadel, R.M.3
  • 39
    • 70349313122 scopus 로고    scopus 로고
    • A single institutional experience of factors affecting successful identification of sentinel lymph node in breast cancer patients
    • M.T. Johnson, J.A. Guidroz, and B.J. Smith A single institutional experience of factors affecting successful identification of sentinel lymph node in breast cancer patients Surgery 146 2009 671 676 discussion: 676-677
    • (2009) Surgery , vol.146 , pp. 671-676
    • Johnson, M.T.1    Guidroz, J.A.2    Smith, B.J.3
  • 40
    • 51449114059 scopus 로고    scopus 로고
    • Optimal number of radioactive sentinel lymph nodes to remove for accurate axillary staging of breast cancer
    • M.A. Lynch, J. Jackson, and J.A. Kim Optimal number of radioactive sentinel lymph nodes to remove for accurate axillary staging of breast cancer Surgery 144 2008 525 531 discussion: 531-532
    • (2008) Surgery , vol.144 , pp. 525-531
    • Lynch, M.A.1    Jackson, J.2    Kim, J.A.3
  • 41
    • 70349462954 scopus 로고    scopus 로고
    • Scientific Impact Award: Axillary reverse mapping (ARM) to identify and protect lymphatics draining the arm during axillary lymphadenectomy
    • C. Boneti, S. Korourian, and Z. Diaz Scientific Impact Award: Axillary reverse mapping (ARM) to identify and protect lymphatics draining the arm during axillary lymphadenectomy Am J Surg 198 2009 482 487
    • (2009) Am J Surg , vol.198 , pp. 482-487
    • Boneti, C.1    Korourian, S.2    Diaz, Z.3
  • 43
    • 67349195733 scopus 로고    scopus 로고
    • The yield of SPECT/CT for anatomical lymphatic mapping in patients with breast cancer
    • I.M. van der Ploeg, O.E. Nieweg, and B.B. Kroon The yield of SPECT/CT for anatomical lymphatic mapping in patients with breast cancer Eur J Nucl Med Mol Imaging 36 2009 903 909
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , pp. 903-909
    • Van Der Ploeg, I.M.1    Nieweg, O.E.2    Kroon, B.B.3
  • 45
    • 0034785427 scopus 로고    scopus 로고
    • Randomized prospective evaluation of a novel technique for biopsy or lumpectomy of nonpalpable breast lesions: Radioactive seed versus wire localization
    • DOI 10.1245/aso.2001.8.9.711
    • R.J. Gray, C. Salud, and K. Nguyen Randomized prospective evaluation of a novel technique for biopsy or lumpectomy of nonpalpable breast lesions: Radioactive seed versus wire localization Ann Surg Oncol 8 2001 711 715 (Pubitemid 32952485)
    • (2001) Annals of Surgical Oncology , vol.8 , Issue.9 , pp. 711-715
    • Gray, R.J.1    Salud, C.2    Nguyen, K.3    Dauway, E.4    Friedland, J.5    Berman, C.6    Peltz, E.7    Whitehead, G.8    Cox, C.E.9
  • 47
    • 0035166734 scopus 로고    scopus 로고
    • Radioguidance for nonpalpable primary lesions and sentinel lymph node(s)
    • DOI 10.1016/S0002-9610(01)00716-4, PII S0002961001007164
    • R.J. Gray, R. Giuliano, and E.L. Dauway Radioguidance for nonpalpable primary lesions and sentinel lymph node(s) Am J Surg 182 2001 404 406 (Pubitemid 33079096)
    • (2001) American Journal of Surgery , vol.182 , Issue.4 , pp. 404-406
    • Gray, R.J.1    Giuliano, R.2    Dauway, E.L.3    Cox, C.E.4    Reintgen, D.S.5
  • 48
    • 77955193596 scopus 로고    scopus 로고
    • Localization of non-palpable breast cancer using a radiolabelled titanium seed
    • Y.E. van Riet, F.H. Jansen, and M. van Beek Localization of non-palpable breast cancer using a radiolabelled titanium seed Br J Surg 97 2010 1240 1245
    • (2010) Br J Surg , vol.97 , pp. 1240-1245
    • Van Riet, Y.E.1    Jansen, F.H.2    Van Beek, M.3
  • 49
    • 77955187290 scopus 로고    scopus 로고
    • Marking the axilla with radioactive iodine seeds (Mari procedure) may reduce the need for axillary dissection after neoadjuvant chemotherapy for breast cancer
    • M.E. Straver, C.E. Loo, and T. Alderliesten Marking the axilla with radioactive iodine seeds (Mari procedure) may reduce the need for axillary dissection after neoadjuvant chemotherapy for breast cancer Br J Surg 97 2010 1226 1231
    • (2010) Br J Surg , vol.97 , pp. 1226-1231
    • Straver, M.E.1    Loo, C.E.2    Alderliesten, T.3
  • 51
    • 34548676165 scopus 로고    scopus 로고
    • Use of Yttrium-90 Microspheres in the Treatment of Unresectable Hepatic Metastases From Breast Cancer
    • DOI 10.1016/j.ijrobp.2007.03.056, PII S0360301607006517
    • D.M. Coldwell, A.S. Kennedy, and C.W. Nutting Use of yttrium-90 microspheres in the treatment of unresectable hepatic metastases from breast cancer Int J Radiat Oncol Biol Phys 69 2007 800 804 (Pubitemid 47418394)
    • (2007) International Journal of Radiation Oncology Biology Physics , vol.69 , Issue.3 , pp. 800-804
    • Coldwell, D.M.1    Kennedy, A.S.2    Nutting, C.W.3
  • 52
    • 42649093160 scopus 로고    scopus 로고
    • Radioembolization in patients with hepatic metastases from breast cancer
    • T.F. Jakobs, R.T. Hoffmann, and T. Fischer Radioembolization in patients with hepatic metastases from breast cancer J Vasc Interv Radiol 19 2008 683 690
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 683-690
    • Jakobs, T.F.1    Hoffmann, R.T.2    Fischer, T.3
  • 53
    • 77950341103 scopus 로고    scopus 로고
    • Radiofrequency ablation after selective internal radiation therapy with yttrium-90 microspheres in metastatic liver disease-Is it feasible?
    • R.T. Hoffmann, T.F. Jakobs, and C.H. Kubisch Radiofrequency ablation after selective internal radiation therapy with yttrium-90 microspheres in metastatic liver disease-Is it feasible? Eur J Radiol 74 2010 199 205
    • (2010) Eur J Radiol , vol.74 , pp. 199-205
    • Hoffmann, R.T.1    Jakobs, T.F.2    Kubisch, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.