메뉴 건너뛰기




Volumn 19, Issue 1, 2011, Pages 1-14

Improvement of pharmaceuticalnear infrared calibrations by empirical target distribution optimisation

Author keywords

Calibration optimisation; Near infrared spectroscopy; Pharmaceutics

Indexed keywords

ERRORS; FORECASTING; INFRARED DEVICES; NEAR INFRARED SPECTROSCOPY; NORMAL DISTRIBUTION; VIBRATIONS (MECHANICAL);

EID: 79953216064     PISSN: 09670335     EISSN: None     Source Type: Journal    
DOI: 10.1255/jnirs.914     Document Type: Article
Times cited : (2)

References (17)
  • 1
    • 0001812991 scopus 로고    scopus 로고
    • Variables affecting near-infrared reflectance spectroscopic analysis
    • Ed by P.C. Williams and K. Norris. American Association of Cereal Chemists, St Paul, MN, USA
    • P.C. Williams, "Variables affecting near-infrared reflectance spectroscopic analysis", in Near-Infrared Technology in the Agricultural and Food Industries, Ed by P.C. Williams and K. Norris. American Association of Cereal Chemists, St Paul, MN, USA, pp. 162-163 (2001).
    • (2001) Near-Infrared Technology in the Agricultural and Food Industries , pp. 162-163
    • Williams, P.C.1
  • 2
    • 0021823775 scopus 로고
    • Multivariate least-squares methods applied to the quantitative spectral analysis of multicomponent samples
    • doi:10.1366/0003702854249376
    • D.M. Haaland, R.G. Easterling and D.A. Vopicka, "Multivariate least-squares methods applied to the quantitative spectral analysis of multicomponent samples", Appl. Spectrosc. 39, 73 (1985). doi: 10.1366/0003702854249376
    • (1985) Appl. Spectrosc. , vol.39 , pp. 73
    • Haaland, D.M.1    Easterling, R.G.2    Vopicka, D.A.3
  • 3
    • 0029879396 scopus 로고    scopus 로고
    • Application of near-infrared reflectance spectrometry to the analytical control of pharmaceuticals: Ranitidine hydrochloride tablet production
    • DOI 10.1039/an9962100219
    • E. Dreassi, G. Ceramelli, P. Corti, P.L. Perruccio and S. Lonardi, "Application of near infrared reflectance spectrometry to the analytical control of pharmaceuticals: ranitidine hydrochloride tablet production", Analyst 121, 219 (1996). doi: 10.1039/an9962100219 (Pubitemid 26080810)
    • (1996) Analyst , vol.121 , Issue.2 , pp. 219-222
    • Dreassi, E.1    Ceramelli, G.2    Corti, P.3    Perruccio, P.L.4    Lonardi, S.5
  • 4
    • 0031766516 scopus 로고    scopus 로고
    • Near-infrared analytical control of pharmaceuticals. A single calibration model from mixed phase to coated tablets
    • DOI 10.1039/a805946b
    • M. Blanco, J. Coello, H. Iturriaga, S. Maspoch and D. Serrano, "Near-infrared analytical control of pharmaceuticals. Asingle calibration model from mixed phase to coated tablets", Analyst 123, 2307 (1998). doi: 10.1039/a805946b (Pubitemid 28528643)
    • (1998) Analyst , vol.123 , Issue.11 , pp. 2307-2312
    • Blanco, M.1
  • 5
    • 0033910049 scopus 로고    scopus 로고
    • Meeting the International Conference on Harmonisation's Guidelines on Validation of Analytical Procedures: Quantification as exemplified by a near-infrared reflectance assay of paracetamol in intact tablets
    • DOI 10.1039/b002672g
    • A.C. Moffat, A.D. Trafford, R.D. Jee and P. Graham, "Meeting of the International Conference on Harmonisation's Guidelines on Validation of Analytical Procedures: Quantification as exemplified by a near-infrared reflectance assay of paracetamol in intact tablets", Analyst 125, 1341 (2000). doi: 10.1039/b002672g (Pubitemid 30458580)
    • (2000) Analyst , vol.125 , Issue.7 , pp. 1341-1351
    • Moffat, A.C.1    Trafford, A.D.2    Jee, R.D.3    Graham, P.4
  • 6
    • 42949131697 scopus 로고    scopus 로고
    • Preparing calibration sets for use in pharmaceutical analysis by NIRspectroscopy
    • doi: 10.1002/jps.21105
    • M. Blanco, M. Bautista and M. Alcalá, "Preparing calibration sets for use in pharmaceutical analysis by NIRspectroscopy", J. Pharm. Sci. 97, 1236 (2008). doi: 10.1002/jps.21105
    • (2008) J. Pharm. Sci. , vol.97 , pp. 1236
    • Blanco, M.1    Bautista, M.2    Alcalá, M.3
  • 7
    • 0034913366 scopus 로고    scopus 로고
    • Influence of the procedure used to prepare the calibration sample set on the performance of near infrared spectroscopy in quantitative pharmaceutical analyses
    • DOI 10.1039/b102090k
    • M. Blanco, J. Coello, H. Iturriaga, S. Maspoch and N. Pou, "Influence of the procedure used to prepare the calibration sample set on the performance of near infrared spectroscopy in quantitative pharmaceutical analyses", Analyst 126, 1129 (2001). doi: 10.1039/b102090k (Pubitemid 32673300)
    • (2001) Analyst , vol.126 , Issue.7 , pp. 1129-1134
    • Blanco, M.1    Coello, J.2    Iturriaga, H.3    Maspoch, S.4    Pou, N.5
  • 8
    • 60249091923 scopus 로고    scopus 로고
    • Quality control of pharmaceuticals with NIR: From lab to process line
    • doi: 10.1016/j.vibspec.2008.07.013
    • M.C. Sarraguja and J.A. Lopes, "Quality control of pharmaceuticals with NIR: From lab to process line", Vib. Spectrosc. 49, 204 (2009). doi: 10.1016/j.vib-spec.2008.07.013
    • (2009) Vib. Spectrosc. , vol.49 , pp. 204
    • Sarraguja, M.C.1    Lopes, J.A.2
  • 9
    • 67649868327 scopus 로고    scopus 로고
    • Development of robust quantitative methods by near-infrared spectroscopy for rapid pharmaceutical determination of content uniformity in complex tablet matrix
    • doi: 10.1039/b821836f
    • D. Xiang, M. Konigsberger, B. Wabuyele, K. Hornung and J. Cheney, "Development of robust quantitative methods by near-infrared spectroscopy for rapid pharmaceutical determination of content uniformity in complex tablet matrix" Analyst 134, 1405 (2009). doi: 10.1039/b821836f
    • (2009) Analyst , vol.134 , pp. 1405
    • Xiang, D.1    Konigsberger, M.2    Wabuyele, B.3    Hornung, K.4    Cheney, J.5
  • 10
    • 33645071917 scopus 로고    scopus 로고
    • Transfer of NIRcalibrations for pharmaceutical formulations between different instruments
    • doi: 10.1016/j.jpba.2005.10.042
    • E.L. Bergman, H. Brage, M. Josefson, O. Svensson and ASparén, "Transfer of NIRcalibrations for pharmaceutical formulations between different instruments", J. Pharm. Biomed. Anal. 41, 89 (2006). doi: 10.1016/j.jpba.2005.10.042
    • (2006) J. Pharm. Biomed. Anal. , vol.41 , pp. 89
    • Bergman, E.L.1    Brage, H.2    Josefson, M.3    Svensson, O.4    Sparén, A.5
  • 11
    • 0031813634 scopus 로고    scopus 로고
    • Transfer of calibration in near-infrared reflectance spectrometry
    • DOI 10.1039/a706694e
    • E. Dreassi, G. Ceramelli, P.L. Perruccio and P. Corti, "Transfer of calibration in near-infrared reflectance spectrometry", Analyst 123, 1259 (1998). doi: 10.1039/a706694e (Pubitemid 28301954)
    • (1998) Analyst , vol.123 , Issue.6 , pp. 1259-1264
    • Dreassi, E.1    Ceramelli, G.2    Perruccio A, P.L.3    Corti, P.4
  • 12
    • 44749088589 scopus 로고    scopus 로고
    • Process characterization of powder blending by near-infrared spectroscopy: Blend end-points and beyond
    • doi: 10.1016/j.jpba.2008.03.013
    • Z. Shi, R.P. Cogdill, S.M. Short and C.A. Anderson, "Process characterization of powder blending by near-infrared spectroscopy: Blend end-points and beyond", J. Pharm. Biomed. Anal. 47, 738 (2008). doi: 10.1016/j.jpba.2008.03.013
    • (2008) J. Pharm. Biomed. Anal. , vol.47 , pp. 738
    • Shi, Z.1    Cogdill, R.P.2    Short, S.M.3    Anderson, C.A.4
  • 13
    • 0342680241 scopus 로고
    • The standardization of Infratec 1221 near infrared transmission instru-ments in the Danish network used for the determination of protein and moisture in grains
    • doi: 10.1225/jnirs.53
    • N.B. Buchmann and S. Runfors, "The standardization of Infratec 1221 near infrared transmission instruments in the Danish network used for the determination of protein and moisture in grains", J. Near Infrared Spectrosc. 3, 35 (1995). doi: 10.1225/jnirs.53
    • (1995) J. Near Infrared Spectrosc. , vol.3 , pp. 35
    • Buchmann, N.B.1    Runfors, S.2
  • 14
    • 0002790172 scopus 로고    scopus 로고
    • Calibration and field standardization of tecator infratec analyzers for corn and soybeans
    • Ed by A.M.C. Davis and P. Williams. NIRPublications, Chichester, UK
    • G.R. Rippke, C.L. Hardy, C.R. Hurburgh and T.J. Brumm, "Calibration and field standardization of Tecator Infratec analyzers for corn and soybeans", in Near Infrared Spectroscopy: The Future Waves, Ed by A.M.C. Davis and P. Williams. NIRPublications, Chichester, UK, p. 122 (1996).
    • (1996) Near Infrared Spectroscopy: The Future waves , pp. 122
    • Rippke, G.R.1    Hardy, C.L.2    Hurburgh, C.R.3    Brumm, T.J.4
  • 15
    • 0037999179 scopus 로고    scopus 로고
    • Applying near infrared spectroscopy to the needs of US grain inspector
    • Ed by A.M.C. Davis and P. Williams. NIRPublications, Chichester, UK
    • R.O. Pierce, D.B. Funk and C.A. Brenner, "Applying near infrared spectroscopy to the needs of US grain inspector", in Near Infrared Spectroscopy: The Future Waves, Ed by A.M.C. Davis and P. Williams. NIRPublications, Chichester, UK, p. 451 (1996).
    • (1996) Near Infrared Spectroscopy: The Future Waves , pp. 451
    • Pierce, R.O.1    Funk, D.B.2    Brenner, C.A.3
  • 17
    • 0024701578 scopus 로고
    • Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra
    • doi: 10.1366/0003702894202201
    • R.J. Barnes, M.S. Dhanoa and S.J. Lister, "Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra", Appl. Spectrosc. 43, 772 (1989). doi: 10.1366/0003702894202201
    • (1989) Appl. Spectrosc. , vol.43 , pp. 772
    • Barnes, R.J.1    Dhanoa, M.S.2    Lister, S.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.