메뉴 건너뛰기




Volumn 19, Issue 7, 2011, Pages 5930-5941

A responsivity-based criterion for accurate calibration of FTIR emission spectra: Identification of in-band low-responsivity wavenumbers

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; EMISSION SPECTROSCOPY; FOURIER TRANSFORM INFRARED SPECTROSCOPY; INFRARED SPECTROMETERS; INSTRUMENT ERRORS; INSTRUMENTS; REMOTE SENSING; SPECTROMETRY; WATER ABSORPTION; WATER VAPOR;

EID: 79953191159     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.19.005930     Document Type: Article
Times cited : (7)

References (14)
  • 2
    • 84975573756 scopus 로고
    • Radiometric calibration of IR Fourier transform spectrometers: Solution to a problem with the high-resolution interferometer sounder
    • H. E. Revercomb, H. Buijs, H. B. Howell, D. D. Laporte, W. L. Smith, and L. A. Sromovsky, "Radiometric calibration of IR Fourier transform spectrometers: Solution to a problem with the high-resolution interferometer sounder," Appl. Opt. 27(15), 3210-3218 (1988).
    • (1988) Appl. Opt. , vol.27 , Issue.15 , pp. 3210-3218
    • Revercomb, H.E.1    Buijs, H.2    Howell, H.B.3    Laporte, D.D.4    Smith, W.L.5    Sromovsky, L.A.6
  • 3
    • 0041976026 scopus 로고    scopus 로고
    • Radiometric errors in complex Fourier transform spectrometry
    • L. A. Sromovsky, "Radiometric errors in complex Fourier transform spectrometry," Appl. Opt. 42(10), 1779-1787 (2003).
    • (2003) Appl. Opt. , vol.42 , Issue.10 , pp. 1779-1787
    • Sromovsky, L.A.1
  • 4
    • 79952598344 scopus 로고    scopus 로고
    • A responsivity-based criterion for accurate calibration of FTIR emission spectra: Theoretical development and bandwidth estimation
    • P. M. Rowe, S. P. Neshyba, and V. P. Walden, "A responsivity-based criterion for accurate calibration of FTIR emission spectra: Theoretical development and bandwidth estimation," Opt. Express 19(6) 5451-5463 (2011)
    • (2011) Opt. Express , vol.19 , Issue.6 , pp. 5451-5463
    • Rowe, P.M.1    Neshyba, S.P.2    Walden, V.P.3
  • 5
    • 75649137802 scopus 로고    scopus 로고
    • Large surface radiative forcing from topographic blowing snow residuals measured in the high arctic at eureka
    • G. Lesins, L. Bourdages, T. Duck, J. Drummond, E. Eloranta, and V. Walden, "Large surface radiative forcing from topographic blowing snow residuals measured in the high arctic at eureka," Atmos. Chem. Phys. 9(6), 1847-1862 (2009).
    • (2009) Atmos. Chem. Phys. , vol.9 , Issue.6 , pp. 1847-1862
    • Lesins, G.1    Bourdages, L.2    Duck, T.3    Drummond, J.4    Eloranta, E.5    Walden, V.6
  • 6
    • 0007559965 scopus 로고    scopus 로고
    • Radiometric calibration for the airborne interferometric monitor for greenhouse gases simulator
    • A. Shimota, H. Kobayashi, and S. Kadokura, "radiometric calibration for the airborne interferometric monitor for greenhouse gases simulator," Appl. Opt. 38(3), 571-576 (1999). (Pubitemid 129577674)
    • (1999) Applied Optics , vol.38 , Issue.3 , pp. 571-576
    • Shimota, A.1    Kobayashi, H.2    Kadokura, S.3
  • 13
    • 63049137653 scopus 로고    scopus 로고
    • Dry bias in Vaisala RS90 radiosonde humidity profiles over antarctica
    • P. Rowe, L. Miloshevich, D. Turner, and V. Walden, "Dry bias in Vaisala RS90 radiosonde humidity profiles over antarctica," J. Atmos. Ocean. Technol. 25(9), 1529-1541 (2008).
    • (2008) J. Atmos. Ocean. Technol. , vol.25 , Issue.9 , pp. 1529-1541
    • Rowe, P.1    Miloshevich, L.2    Turner, D.3    Walden, V.4
  • 14
    • 84894389712 scopus 로고    scopus 로고
    • Data from the AERI operated at the North Slope of Alaska is available at
    • Data from the AERI operated at the North Slope of Alaska is available at http://www.archive.arm.gov.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.