메뉴 건너뛰기




Volumn 24, Issue 4, 2011, Pages 431-437

Real-time three-dimensional transesophageal echocardiography in patients with secundum atrial septal defects: Outcomes following transcatheter closure

Author keywords

Atrial septal defect; Three dimensional transesophageal echocardiography

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; FEMALE; FOLLOW UP; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HEART RIGHT LEFT SHUNT; HUMAN; MALE; REAL TIME ECHOGRAPHY; SEPTAL OCCLUDER; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TREATMENT OUTCOME; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 79953164555     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.echo.2010.12.011     Document Type: Article
Times cited : (50)

References (8)
  • 2
    • 46449117701 scopus 로고    scopus 로고
    • Real-time three-dimensional transoesophageal echocardiography for guidance of atrial septal defect closures
    • J. Balzer, H. Kuhl, and A. Franke Real-time three-dimensional transoesophageal echocardiography for guidance of atrial septal defect closures Eur Heart J 29 2008 2226
    • (2008) Eur Heart J , vol.29 , pp. 2226
    • Balzer, J.1    Kuhl, H.2    Franke, A.3
  • 3
    • 0026566731 scopus 로고
    • Morphologic study of defects of the atrial septum within the oval fossa: Implications for transcatheter closure of left-to-right shunt
    • S.M. Ferrreira, S.Y. Ho, and R.H. Anderson Morphologic study of defects of the atrial septum within the oval fossa: implications for transcatheter closure of left-to-right shunt Br Heart J 67 1992 316 320
    • (1992) Br Heart J , vol.67 , pp. 316-320
    • Ferrreira, S.M.1    Ho, S.Y.2    Anderson, R.H.3
  • 4
    • 0027506768 scopus 로고
    • Morphological variations of fossa ovalis atrial septal defects (secundum): Feasibility for transcutaneous closure with the clam-shell device
    • K. Chan, and M. Godman Morphological variations of fossa ovalis atrial septal defects (secundum): feasibility for transcutaneous closure with the clam-shell device Br Heart J 69 1993 52 55 (Pubitemid 23036642)
    • (1993) British Heart Journal , vol.69 , Issue.1 , pp. 52-55
    • Chan, K.C.1    Godman, M.J.2
  • 5
    • 67650354356 scopus 로고    scopus 로고
    • Feasibility of real-time three-dimensional transesophageal echocardiography for guidance of percutaneous atrial septal defect closure
    • J.A. Lodato, Q.L. Cao, L. Weinert, L. Sugeng, J. Lopez, and R.M. Lang Feasibility of real-time three-dimensional transesophageal echocardiography for guidance of percutaneous atrial septal defect closure Eur J Echocardiogr 10 2009 543 548
    • (2009) Eur J Echocardiogr , vol.10 , pp. 543-548
    • Lodato, J.A.1    Cao, Q.L.2    Weinert, L.3    Sugeng, L.4    Lopez, J.5    Lang, R.M.6
  • 6
    • 0034017329 scopus 로고    scopus 로고
    • Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device. A three-dimensional transoesophageal echocardiographic reconstruction
    • DOI 10.1053/euhj.1999.1855
    • P. Acar, Z. Saliba, P. Bonhoeffer, Y. Aggoun, D. Bonnet, and D. Sidi Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device. A three-dimensional transesophageal echocardiographic reconstruction Eur Heart J 21 2000 573 581 (Pubitemid 30148322)
    • (2000) European Heart Journal , vol.21 , Issue.7 , pp. 573-581
    • Acar, P.1    Saliba, Z.2    Bonhoeffer, P.3    Aggoun, Y.4    Bonnet, D.5    Sidi, D.6    Kachaner, J.7
  • 7
    • 0034987187 scopus 로고    scopus 로고
    • Dynamic changes of atrial septal defect area: New insights by three-dimensional volume-rendered echocardiography with high temporal resoluton
    • DOI 10.1053/euje.2000.0064
    • M. Handke, D.M. Schafer, G. Muller, A. Schochlin, E. Magosaki, and A. Geibel Dynamic changes of atrial septal defect area: new insights by three-dimensional volume-rendered echocardiography with high temporal resolution Eur J Echocardiogr 2 2001 46 51 (Pubitemid 32496442)
    • (2001) European Journal of Echocardiography , vol.2 , Issue.1 , pp. 46-51
    • Handke, M.1    Schafer, D.M.2    Muller, G.3    Schochlin, A.4    Magosaki, E.5    Geibel, A.6
  • 8
    • 70349435988 scopus 로고    scopus 로고
    • Application of real-time three-dimensional transesophageal echocardiography using a matrix array probe for transcatheter closure of atrial septal defect
    • M. Taniguchi, T. Akagi, N. Watanabe, Y. Okamoto, K. Nakagawa, and Y. Kijima Application of real-time three-dimensional transesophageal echocardiography using a matrix array probe for transcatheter closure of atrial septal defect J Am Soc Echocardiogr 22 2009 1114 1120
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 1114-1120
    • Taniguchi, M.1    Akagi, T.2    Watanabe, N.3    Okamoto, Y.4    Nakagawa, K.5    Kijima, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.