메뉴 건너뛰기




Volumn 44, Issue 6, 2011, Pages 1205-1208

Major and minor centroidal axes serve as objective, automatable reference points to test mechanobiological hypotheses using histomorphometry

Author keywords

Anatomy; Bone; Centroidal axis; Histomorphometry; Imaging; Mechanics; Mechanoadaptation; Mechanobiology

Indexed keywords

ANATOMY; CENTROIDAL AXIS; HISTOMORPHOMETRY; IMAGING; MECHANO-BIOLOGY; MECHANOADAPTATION;

EID: 79953025759     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2011.01.033     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 0037401034 scopus 로고    scopus 로고
    • An experimental two degrees-of-freedom actuated external fixator for in vivo investigation of fracture healing
    • Bishop N.E., Schneider E, Ito K. An experimental two degrees-of-freedom actuated external fixator for in vivo investigation of fracture healing. Medical Engineering Physics 2003, 25:335-340.
    • (2003) Medical Engineering Physics , vol.25 , pp. 335-340
    • Bishop, N.E.1    Schneider, E.2    Ito, K.3
  • 3
    • 77958153384 scopus 로고    scopus 로고
    • Effects of mechanical loading patterns, bone graft and proximity to periosteum on bone defect healing
    • Knothe U., Dolejs S., Miller R.M., Knothe Tate M.L. Effects of mechanical loading patterns, bone graft and proximity to periosteum on bone defect healing. Journal of Biomechanics 2010, 43:2728-2737.
    • (2010) Journal of Biomechanics , vol.43 , pp. 2728-2737
    • Knothe, U.1    Dolejs, S.2    Miller, R.M.3    Knothe Tate, M.L.4
  • 6
    • 33846781432 scopus 로고    scopus 로고
    • Testing of a new one-stage bone-transport surgical procedure exploiting the periosteum and bone transport for repair of long bone defects
    • Knothe Tate M.L., Ritzman T., Schneider E., Knothe U. Testing of a new one-stage bone-transport surgical procedure exploiting the periosteum and bone transport for repair of long bone defects. Journal of Bone and Joint Surgery American 2007, 89:307-316.
    • (2007) Journal of Bone and Joint Surgery American , vol.89 , pp. 307-316
    • Knothe Tate, M.L.1    Ritzman, T.2    Schneider, E.3    Knothe, U.4
  • 8
    • 79954449018 scopus 로고    scopus 로고
    • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects. Ann. Biomed. Eng., PMID: 21271290, doi:.
    • McBride, S.H., Dolejs, S., Brianza, S., Knothe, U., Knothe, Tate, M.L., 2011. Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects. Ann. Biomed. Eng., PMID: 21271290, doi:. http://10.1007/s10439-010-0242-9.
    • (2011)
    • McBride, S.H.1    Dolejs, S.2    Brianza, S.3    Knothe, U.4    Knothe Tate, M.L.5
  • 12
    • 0028267333 scopus 로고
    • Noninvasive loading of the rat ulna in vivo induces a strain-related modeling response uncomplicated by trauma or periosteal pressure
    • Torrance A.G., Mosley J.R., Suswillo R.F., Lanyon L.E. Noninvasive loading of the rat ulna in vivo induces a strain-related modeling response uncomplicated by trauma or periosteal pressure. Calcified Tissue International 1994, 54:241-247.
    • (1994) Calcified Tissue International , vol.54 , pp. 241-247
    • Torrance, A.G.1    Mosley, J.R.2    Suswillo, R.F.3    Lanyon, L.E.4