메뉴 건너뛰기




Volumn 4, Issue 3, 2011, Pages 347-352

Radial artery access as a predictor of increased radiation exposure during a diagnostic cardiac catheterization procedure

Author keywords

air kerma; cardiac catheterization; multilevel model; radial access; radiation exposure

Indexed keywords

ADULT; ARTICLE; BODY MASS; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; FEMALE; FEMORAL ARTERY; FLUOROSCOPY; HEART CATHETERIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; OPERATOR; PERIPHERAL VASCULAR DISEASE; PREDICTOR VARIABLE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIAL ARTERY; RADIATION EXPOSURE; VASCULAR ACCESS;

EID: 79953017647     PISSN: 19368798     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcin.2010.11.011     Document Type: Article
Times cited : (95)

References (17)
  • 1
    • 48149108439 scopus 로고    scopus 로고
    • Radiation dose in interventional cardiology procedures: Urgent need for monitoring dose and establishing diagnostic reference levels
    • Hamilton Health Sciences Interventional Cardiology Staff L.
    • M. Mercuri, G.R. Moran, L. Gauthier Hamilton Health Sciences Interventional Cardiology Staff Radiation dose in interventional cardiology procedures: urgent need for monitoring dose and establishing diagnostic reference levels Healthc Q 11 2008 76 83
    • (2008) Healthc Q , vol.11 , pp. 76-83
    • Mercuri, M.1    Moran, G.R.2    Gauthier3
  • 2
    • 72049125113 scopus 로고    scopus 로고
    • Predictors of increased radiation dose during percutaneous coronary intervention
    • M. Mercuri, C. Xie, M. Levy, N. Valettas, and M.K. Natarajan Predictors of increased radiation dose during percutaneous coronary intervention Am J Cardiol 104 2009 1241 1244
    • (2009) Am J Cardiol , vol.104 , pp. 1241-1244
    • Mercuri, M.1    Xie, C.2    Levy, M.3    Valettas, N.4    Natarajan, M.K.5
  • 3
    • 37849015920 scopus 로고    scopus 로고
    • Comparison of operator radiation exposure with optimized radiation protection devices during coronary angiograms and ad hoc percutaneous coronary interventions by radial and femoral routes
    • C. Brasselet, T. Blanpain, and S. Tassan-Mangina Comparison of operator radiation exposure with optimized radiation protection devices during coronary angiograms and ad hoc percutaneous coronary interventions by radial and femoral routes Eur Heart J 29 2008 63 70
    • (2008) Eur Heart J , vol.29 , pp. 63-70
    • Brasselet, C.1    Blanpain, T.2    Tassan-Mangina, S.3
  • 4
    • 1842555279 scopus 로고    scopus 로고
    • Evaluation of patient-absorbed doses during coronary angiography and intervention by femoral and radial artery access
    • DOI 10.1007/s00330-003-2120-4
    • M. Sandborg, S.G. Fransson, and H. Pettersson Evaluation of patient-absorbed doses during coronary angiography and intervention by femoral and radial artery access Eur Radiol 14 2004 653 658 (Pubitemid 38444579)
    • (2004) European Radiology , vol.14 , Issue.4 , pp. 653-658
    • Sandborg, M.1    Fransson, S.-G.2    Peterson, H.3
  • 5
    • 0041368715 scopus 로고    scopus 로고
    • Factors influencing fluoroscopy time and dose-area product values during and hoc one-vessel percutaneous coronary angioplasty
    • DOI 10.1259/bjr/21553230
    • F. Larrazet, A. Dibie, F. Philippe, R. Palau, R. Klausz, and F. Laborde Factors influencing fluoroscopy time and dose-are product values during ad hoc one-vessel percutaneous coronary angioplasty Br J Radiol 76 2003 473 477 (Pubitemid 36903362)
    • (2003) British Journal of Radiology , vol.76 , Issue.907 , pp. 473-477
    • Larrazet, F.1    Dibie, A.2    Philippe, F.3    Palau, R.4    Klausz, R.5    Laborde, F.6
  • 7
    • 30344458162 scopus 로고    scopus 로고
    • Randomized comparison of operator radiation exposure during coronary angiography and intervention by radial or femoral approach
    • DOI 10.1002/ccd.20451
    • H.W. Lange, and H. von Boetticher Randomized comparison of operator radiation exposure during coronary angiography and intervention by radial or femoral approach Catheter Cardiovasc Interv 67 2006 12 16 (Pubitemid 43062600)
    • (2006) Catheterization and Cardiovascular Interventions , vol.67 , Issue.1 , pp. 12-16
    • Lange, H.W.1    Von Boetticher, H.2
  • 8
    • 24944444304 scopus 로고    scopus 로고
    • Radial versus femoral access for emergent percutaneous coronary intervention with adjunct glycoprotein IIb/IIIa inhibition in acute myocardial infarction - The RADIAL-AMI pilot randomized trial
    • DOI 10.1016/j.ahj.2004.10.043, PII S0002870305001559
    • W.J. Cantor, G. Puley, and M.K. Natarajan Radial versus femoral access for emergent percutaneous coronary intervention with adjunct glycoprotein IIb/IIIa inhibition in acute myocardial infarctionthe RADIAL-AMI pilot randomized trial Am Heart J 150 2005 543 549 (Pubitemid 41317627)
    • (2005) American Heart Journal , vol.150 , Issue.3 , pp. 543-549
    • Cantor, W.J.1    Puley, G.2    Natarajan, M.K.3    Dzavik, V.4    Madan, M.5    Fry, A.6    Kim, H.H.7    Velianou, J.L.8    Pirani, N.9    Strauss, B.H.10    Chisholm, R.J.11
  • 9
    • 67650626450 scopus 로고    scopus 로고
    • Insight into capacity planning for cardiac catheterization services: Policy lessons learned from "looking in the Mirror" over a decade
    • M. Mercuri, M.K. Natarajan, D.H. Holder, C. Xie, and A. Gafni Insight into capacity planning for cardiac catheterization services: policy lessons learned from "Looking in the Mirror" over a decade Health Policy 91 2009 314 320
    • (2009) Health Policy , vol.91 , pp. 314-320
    • Mercuri, M.1    Natarajan, M.K.2    Holder, D.H.3    Xie, C.4    Gafni, A.5
  • 11
    • 0346752330 scopus 로고    scopus 로고
    • Is patient size important in dose determination and optimization in cardiology?
    • DOI 10.1088/0031-9155/48/23/003, PII S0031915503624668
    • J. Reay, C.L. Chapple, and C.J. Kotre Is patient size important in dose determination and optimization in cardiology? Phys Med Biol 48 2003 3843 3850 (Pubitemid 37540462)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.23 , pp. 3843-3850
    • Reay, J.1    Chapple, C.L.2    Kotre, C.J.3
  • 14
    • 42649106144 scopus 로고    scopus 로고
    • Radiation exposure in invasive cardiology
    • DOI 10.1136/hrt.2007.125021
    • E. Kuon Radiation exposure in invasive cardiology Heart 94 2008 667 674 (Pubitemid 351596228)
    • (2008) Heart , vol.94 , Issue.5 , pp. 667-674
    • Kuon, E.1
  • 15
    • 57149103475 scopus 로고    scopus 로고
    • Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: A systematic review and meta-analysis of randomized trials
    • S.S. Jolly, S. Amlani, M. Hamon, S. Yusuf, and S.R. Mehta Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: a systematic review and meta-analysis of randomized trials Am Heart J 157 2009 132 140
    • (2009) Am Heart J , vol.157 , pp. 132-140
    • Jolly, S.S.1    Amlani, S.2    Hamon, M.3    Yusuf, S.4    Mehta, S.R.5
  • 16
    • 65549097351 scopus 로고    scopus 로고
    • Occupational health hazards in the interventional laboratory: Time for a safer environment
    • Joint Inter-Society Task Force on Occupational Hazards in the Interventional Laboratory S.
    • L.W. Klein, D.L. Miller, S. Balter Joint Inter-Society Task Force on Occupational Hazards in the Interventional Laboratory Occupational health hazards in the interventional laboratory: time for a safer environment Catheter Cardiovasc Interv 73 2009 432 438
    • (2009) Catheter Cardiovasc Interv , vol.73 , pp. 432-438
    • Klein, L.W.1    Miller, D.L.2    Balter3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.