메뉴 건너뛰기




Volumn 37, Issue 1, 2011, Pages 184-189

Dynamic calculation of conductor temperature of single-cable using BP neural network

Author keywords

BP neural network; Conductor temperature; Error analysis; Experiment result; Single cable; Surface temperature

Indexed keywords

ACTUAL CURRENT; BP NEURAL NETWORK MODEL; BP NEURAL NETWORKS; CABLE CAPACITY; CONDUCTOR TEMPERATURE; DYNAMIC CALCULATIONS; MEASURED DATA; OPERATING CABLE; PHYSICAL PARAMETERS; SINGLE-CABLE; SINGLE-CORE CABLES; SURFACE TEMPERATURE; SURFACE TEMPERATURES; TEMPERATURE RISING; TEST DATA;

EID: 79953001793     PISSN: 10036520     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (42)

References (28)
  • 1
    • 45949087696 scopus 로고    scopus 로고
    • Calculation of the static temperature field of underground cables using heat charge simulation method
    • LIANG Yong-chun, LI Yan-mu, LI Yan-ming, et al. Calculation of the static temperature field of underground cables using heat charge simulation method[J]. Proceedings of the CSEE, 2008, 28(16): 128-134.
    • (2008) Proceedings of the CSEE , vol.28 , Issue.16 , pp. 128-134
    • Liang, Y.-C.1    Li, Y.-M.2    Li, Y.-M.3
  • 4
    • 0033224128 scopus 로고    scopus 로고
    • Surface temperature field based online diagnoses study for electric cale's conductor temperature
    • ZHAO Jian-hua, YUAN Hong-yong, FAN Wei-cheng, et al. Surface temperature field based online diagnoses study for electric cale's conductor temperature[J]. Proceedings of the CSEE, 1999, 19(11): 52-58.
    • (1999) Proceedings of the CSEE , vol.19 , Issue.11 , pp. 52-58
    • Zhao, J.-H.1    Yuan, H.-Y.2    Fan, W.-C.3
  • 6
    • 42249084047 scopus 로고    scopus 로고
    • Effects of backfilling on cable ampacity analyzed with the finite element method
    • Francisco George J. Effects of backfilling on cable ampacity analyzed with the finite element method[J]. IEEE Transactions on Power Delivery, 2008, 23(2): 537-543.
    • (2008) IEEE Transactions on Power Delivery , vol.23 , Issue.2 , pp. 537-543
    • Francisco George, J.1
  • 7
    • 58249144484 scopus 로고    scopus 로고
    • Thermal resistance properties of the part between metal sheat hand conductor in high-voltage power cable
    • ZHAO Jian-kang, FAN You-bing, WANG Xiao-bing, et al. Thermal resistance properties of the part between metal sheat hand conductor in high-voltage power cable[J]. High Voltage Engineering, 2008, 34(11): 2483-2487.
    • (2008) High Voltage Engineering , vol.34 , Issue.11 , pp. 2483-2487
    • Zhao, J.-K.1    Fan, Y.-B.2    Wang, X.-B.3
  • 8
    • 33750408541 scopus 로고    scopus 로고
    • Distributed temperature system applied in cable temperature measurement
    • PENG Chao, ZHAO Jian-kang, MIAO Fu-gui. Distributed temperature system applied in cable temperature measurement[J]. High Voltage Engineering, 2006, 32(8): 43-45.
    • (2006) High Voltage Engineering , vol.32 , Issue.8 , pp. 43-45
    • Peng, C.1    Zhao, J.-K.2    Miao, F.-G.3
  • 9
    • 33947530592 scopus 로고    scopus 로고
    • Application of operation temperature detection technique for on-line power cable lines
    • LUO Jun-hua, ZHOU Zuo-chun, LI Hua-chun, et al. Application of operation temperature detection technique for on-line power cable lines[J]. High Voltage Engineering, 2007, 33(1): 169-172.
    • (2007) High Voltage Engineering , vol.33 , Issue.1 , pp. 169-172
    • Luo, J.-H.1    Zhou, Z.-C.2    Li, H.-C.3
  • 11
    • 20544472782 scopus 로고    scopus 로고
    • Mathematical method of temperature calculation of power cable conductor in real time
    • LIU Yi-gang, LUO Jun-hua. Mathematical method of temperature calculation of power cable conductor in real time[J]. High Voltage Engineering, 2005, 31(5): 52-54.
    • (2005) High Voltage Engineering , vol.31 , Issue.5 , pp. 52-54
    • Liu, Y.-G.1    Luo, J.-H.2
  • 12
    • 0022102483 scopus 로고
    • Calculations of temperature distributions within cable trench backfill and the surrounding soil
    • Tarasiewicz E, Kuffel E, Grzybowski S. Calculations of temperature distributions within cable trench backfill and the surrounding soil[J]. IEEE Transactions on Apparatus and Systems, 1985, 3(8): 1973-1977.
    • (1985) IEEE Transactions on Apparatus and Systems , vol.3 , Issue.8 , pp. 1973-1977
    • Tarasiewicz, E.1    Kuffel, E.2    Grzybowski, S.3
  • 13
    • 36248961057 scopus 로고    scopus 로고
    • Calculation of eddy current losses in XLPE cables by FEM
    • LIANG Yong-chun, CHAI Jin-ai, LI Yan-ming, et al. Calculation of eddy current losses in XLPE cables by FEM[J]. High Voltage Engineering, 2007, 33(9): 196-199.
    • (2007) High Voltage Engineering , vol.33 , Issue.9 , pp. 196-199
    • Liang, Y.-C.1    Chai, J.-A.2    Li, Y.-M.3
  • 14
    • 0024088043 scopus 로고
    • Power cable thermal analysis with considerations of heat and moisture transfer in the soil
    • Anders G J. Power cable thermal analysis with considerations of heat and moisture transfer in the soil[J]. IEEE Transactions on Power Delivery, 1988, 3(4): 1280-1285.
    • (1988) IEEE Transactions on Power Delivery , vol.3 , Issue.4 , pp. 1280-1285
    • Anders, G.J.1
  • 15
    • 0020780669 scopus 로고
    • Emergency ampacities of direct buried three phase underground cable systems
    • Black W L, Park Sang-il. Emergency ampacities of direct buried three phase underground cable systems[J]. IEEE Transactions on Power Apparatus and Systems, 1983, 5(7): 2124-2132.
    • (1983) IEEE Transactions on Power Apparatus and Systems , vol.5 , Issue.7 , pp. 2124-2132
    • Black, W.L.1    Park, S.-I.2
  • 16
    • 77950344597 scopus 로고    scopus 로고
    • Calculation and experiment of transient temperatures of single-core cables on jacket temperature monitoring
    • NIU Hai-qing, ZHOU Xin, WANG Xiao-bing, et al. Calculation and experiment of transient temperatures of single-core cables on jacket temperature monitoring[J]. High Voltage Engineering, 2009, 35(9): 2138-2143.
    • (2009) High Voltage Engineering , vol.35 , Issue.9 , pp. 2138-2143
    • Niu, H.-Q.1    Zhou, X.2    Wang, X.-B.3
  • 17
    • 77950363222 scopus 로고
    • Calculation of t he current rating of electric cables. Part 3: Sections on operating conditions. Section 1: Reference operating conditions and selection of cable type
    • IEC 60287-3-1: 1995
    • IEC 60287-3-1: 1995 Calculation of t he current rating of electric cables, part 3: sections on operating conditions, section 1: reference operating conditions and selection of cable type[S], 1995.
    • (1995)
  • 18
    • 27144512878 scopus 로고
    • Calculation of the current rating of electric cables. Part 1: Current rating equations (100% load factor) and calculation of losses. Section 1: General
    • IEC 60287-1-1: 1994
    • IEC 60287-1-1: 1994 Calculation of the current rating of electric cables, part 1: current rating equations (100% load factor) and calculation of losses, section 1: general[S], 1994.
    • (1994)
  • 19
    • 57949104478 scopus 로고
    • Calculation of the current rating of electric cables. Part 1: Current rating equations (100% load factor) and calculation of losses. Section 2: Sheath eddy current loss factor for two circuit s in flat formation
    • IEC 60287-1-2: 1993
    • IEC 60287-1-2: 1993 Calculation of the current rating of electric cables, part 1: current rating equations (100% load factor) and calculation of losses, section 2: sheath eddy current loss factor for two circuit s in flat formation[S], 1993.
    • (1993)
  • 20
    • 77950562118 scopus 로고    scopus 로고
    • Theoretical calculation and experimental research on thermal time constant of single-core cables
    • ZHANG Yao, ZHOU Xin, NIU Hai-qing, et al. Theoretical calculation and experimental research on thermal time constant of single-core cables[J]. High Voltage Engineering, 2009, 35(11): 2801-2806.
    • (2009) High Voltage Engineering , vol.35 , Issue.11 , pp. 2801-2806
    • Zhang, Y.1    Zhou, X.2    Niu, H.-Q.3
  • 21
    • 77953770034 scopus 로고    scopus 로고
    • Dynamic calculation of core temperature of single core cables using laplace method
    • LEI Ming, LIU Gang, LAI Yu-ting, et al. Dynamic calculation of core temperature of single core cables using laplace method[J]. High Voltage Engineering, 2010, 36(5): 1150-1155.
    • (2010) High Voltage Engineering , vol.36 , Issue.5 , pp. 1150-1155
    • Lei, M.1    Liu, G.2    Lai, Y.-T.3
  • 24
    • 67651159048 scopus 로고    scopus 로고
    • Optimal design method for wind turbine airfoil based on artificial neural network model and genetic algorithm
    • JU Ya-ping, ZHANG Chu-hua. Optimal design method for wind turbine airfoil based on artificial neural network model and genetic algorithm[J]. Proceedings of the CSEE, 2009, 29(20): 106-111.
    • (2009) Proceedings of the CSEE , vol.29 , Issue.20 , pp. 106-111
    • Ju, Y.-P.1    Zhang, C.-H.2
  • 26
    • 8844272784 scopus 로고    scopus 로고
    • YE Shi-wei, SHI Zhong-zhi, translated. Beijing, China: Machinery Industry Press
    • Simon Haykin. Neural network theory[M]. YE Shi-wei, SHI Zhong-zhi, translated. Beijing, China: Machinery Industry Press, 2004.
    • (2004) Neural Network Theory
    • Haykin, S.1
  • 27
    • 57949092703 scopus 로고    scopus 로고
    • Study on the time-series wind speed forecasting of the wind farm based on neuralnetworks
    • XIAO Yong-shan, WANG Wei-qing, HUO Xiao-ping. Study on the time-series wind speed forecasting of the wind farm based on neuralnetworks[J]. Energy Conservation Technology, 2007, 25(2): 106-108.
    • (2007) Energy Conservation Technology , vol.25 , Issue.2 , pp. 106-108
    • Xiao, Y.-S.1    Wang, W.-Q.2    Huo, X.-P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.