Volumn 3, Issue 3, 2011, Pages 745-750

Correction of migration time of Paeoniae Radix in capillary electrophoresis by powerful one-marker technology

Author keywords

[No Author keywords available]

Indexed keywords

COMPLEX SAMPLES; CRUDE DRUGS; ELECTROPHEROGRAMS; GROWING REGIONS; MIGRATION TIME; PAEONIAE RADIXES; RELATIVE STANDARD DEVIATIONS; REPRODUCIBILITIES;

EID: 79952974151     PISSN: 17599660     EISSN: 17599679     Source Type: Journal    
DOI: 10.1039/c0ay00273a     Document Type: Article
Times cited : (5)

References (23)
  • 2
    • 8844277670 scopus 로고    scopus 로고
    • Recent advances in analysis of Chinese medical plants and traditional medicines
    • P. Draar J. Moravcova Recent advances in analysis of Chinese medical plants and traditional medicines J Chromatogr A 2004 812 3 12
    • (2004) J Chromatogr A , vol.812 , pp. 3-12
    • Draar, P.1    Moravcova, J.2
  • 3
    • 53149093610 scopus 로고    scopus 로고
    • Quality control of herbal medicines by capillary electrophoresis: Potential, requirements and applications
    • M. Ganzera Quality control of herbal medicines by capillary electrophoresis: Potential, requirements and applications Electrophoresis 2008 29 3489 3503
    • (2008) Electrophoresis , vol.29 , pp. 3489-3503
    • Ganzera, M.1
  • 5
    • 0033978160 scopus 로고    scopus 로고
    • Migration time correction for the analysis of derivatized amino acids and oligosaccharides by micellar capillary electrochromatography
    • DOI 10.1016/S0021-9673(99)00893-6, PII S0021967399008936
    • X.-F. Li H. Ren X. Le M. Qi I. D. Ireland N. J. Dovich Migration time correction for the analysis of derivatized amino acids and oligosaccharides by micellar capillary electrochromatography J. Chromatogr., A 2000 869 375 384 (Pubitemid 30066415)
    • (2000) Journal of Chromatography A , vol.869 , Issue.1-2 , pp. 375-384
    • Li, X.-F.1    Ren, H.J.2    Le, X.C.3    Qi, M.4    Ireland, I.D.5    Dovichi, N.J.6
  • 6
    • 62249179246 scopus 로고    scopus 로고
    • Fluorescein thiocarbamyl amino acids as internal standards for migration time correction in capillary sieving electrophoresis
    • H. R. Pugsley K. E. Swearingen N. J. Dovichi Fluorescein thiocarbamyl amino acids as internal standards for migration time correction in capillary sieving electrophoresis J. Chromatogr., A 2009 1216 3418 3420
    • (2009) J. Chromatogr., A , vol.1216 , pp. 3418-3420
    • Pugsley, H.R.1    Swearingen, K.E.2    Dovichi, N.J.3
  • 7
    • 0001339664 scopus 로고
    • Marker techniques for high-accuracy identification in CZE
    • J. H. Jumppanen M.-L. Riekkola Marker techniques for high-accuracy identification in CZE Anal. Chem. 1995 67 1060 1066
    • (1995) Anal. Chem. , vol.67 , pp. 1060-1066
    • Jumppanen, J.H.1    Riekkola, M.-L.2
  • 8
    • 0342468269 scopus 로고    scopus 로고
    • Determination of morphine analogues, caffeine and amphetamine in biological fluids by capillary electrophoresis with the marker technique
    • DOI 10.1016/0021-9673(96)00067-2
    • T. Hyötyläinen H. Sirén M.-L. Riekkola Determination of morphine analogues, caffeine and amphetamine in biological fluids by capillary electrophoresis with the marker technique J. Chromatogr., A 1996 735 439 447 (Pubitemid 26202397)
    • (1996) Journal of Chromatography A , vol.735 , Issue.1-2 , pp. 439-447
    • Hyotylainen, T.1    Siren, H.2    Riekkola, M.-L.3
  • 9
    • 0033566036 scopus 로고    scopus 로고
    • Multiplexed capillary zone electrophoresis and micellar electrokinetic chromatography with internal standardization
    • DOI 10.1021/ac990062b
    • G. Xue M. H-Pang E. S. Yeung Multiplexed capillary zone electrophoresis and micellar electrokinetic chromatography with internal standardization Anal. Chem. 1999 71 2642 2649 (Pubitemid 29340449)
    • (1999) Analytical Chemistry , vol.71 , Issue.14 , pp. 2642-2649
    • Xue, G.1    Pang, H.-M.2    Yeung, E.S.3
  • 10
    • 33644539230 scopus 로고    scopus 로고
    • Identification of the electrophoretic peaks of the phenylthiohydantoin derivatives of amino acids
    • K. V. Stepanov A. V. Pirogov O. A. Shpigun Identification of the electrophoretic peaks of the phenylthiohydantoin derivatives of amino acids J. Anal. Chem. 2006 61 6 13
    • (2006) J. Anal. Chem. , vol.61 , pp. 6-13
    • Stepanov, K.V.1    Pirogov, A.V.2    Shpigun, O.A.3
  • 11
    • 0034077988 scopus 로고    scopus 로고
    • Intra- and interinstrument reproducibility of migration parameters in capillary electrophoresis for substance identification in systematic toxicological analysis
    • DOI 10.1002/(SICI)1522-2683(20000501)21:8<1545::AID-ELPS1545>3.0. CO;2-6
    • C. M. Boone J.-P. Franke R. A. de Zeeuw K. Ensing Intra- and interinstrument reproducibility of migration parameters in capillary electrophoresis for substance identification in systematic toxicological analysis Electrophoresis 2000 21 1545 1551 (Pubitemid 30340977)
    • (2000) Electrophoresis , vol.21 , Issue.8 , pp. 1545-1551
    • Boone, C.M.1    Franke, J.-P.2    De Zeeuw, R.A.3    Ensing, K.4
  • 13
    • 77953215886 scopus 로고    scopus 로고
    • Improved reproducibility of capillary zone electrophoresis through migration ratio method aided by the sudden change in electric current
    • H. Y. Zhang Q. F. Li X. G. Chen Z. D. Hu Improved reproducibility of capillary zone electrophoresis through migration ratio method aided by the sudden change in electric current Chinese J Anal Chem. 2001 29 775 778
    • (2001) Chinese J Anal Chem. , vol.29 , pp. 775-778
    • Zhang, H.Y.1    Li, Q.F.2    Chen, X.G.3    Hu, Z.D.4
  • 15
    • 0029942293 scopus 로고    scopus 로고
    • Improved reproducibility in capillary electrophoresis through the use of mobility and migration time ratios
    • DOI 10.1016/0021-9673(95)00849-7
    • J. Yang S. Bose D. S. Hage Improved reproducibility in capillary electrophoresis through the use of mobility and migration time ratios J. Chromatogr., A 1996 735 209 220 (Pubitemid 26201992)
    • (1996) Journal of Chromatography A , vol.735 , Issue.1-2 , pp. 209-220
    • Yang, J.1    Bose, S.2    Hage, D.S.3
  • 17
    • 0037183737 scopus 로고    scopus 로고
    • Paeoniae Radix, a Chinese herbal extract, inhibit hepatoma cells growth by inducing apoptosis in a p53 independent pathway
    • DOI 10.1016/S0024-3205(02)01962-8, PII S0024320502019628
    • S. M. Y. Lee M. L. Y. Li Y. C. Tse S. C. L. Leung M. M. S. Lee S. K. W. Tsui K. P. Fung C. Y. Lee M. M. Y. Waye Paeoniae Radix, a Chinese herbal extract, inhibit hepatoma cells growth by inducing apoptosis in a p53 independent pathway Life Sci. 2002 71 2267 2277 (Pubitemid 35246215)
    • (2002) Life Sciences , vol.71 , Issue.19 , pp. 2267-2277
    • Lee, S.M.Y.1    Li, M.L.Y.2    Tse, Y.C.3    Leung, S.C.L.4    Lee, M.M.S.5    Tsui, S.K.W.6    Fung, K.P.7    Lee, C.Y.8    Waye, M.M.Y.9
  • 18
    • 0030575858 scopus 로고    scopus 로고
    • Capillary electrophoretic determination of the constituents of Paeoniae Radix
    • H.-K. Wu S.-J. Sheu Capillary electrophoretic determination of the constituents of Paeoniae Radix J. Chromatogr., A 1996 753 139 14
    • (1996) J. Chromatogr., A , vol.753 , pp. 139-14
    • Wu, H.-K.1    Sheu, S.-J.2
  • 19
    • 0025126067 scopus 로고
    • Analysis of the components of Paeonia radix by capillary zone electrophoresis
    • DOI 10.1016/S0021-9673(01)89366-3
    • S. Honda K. Suzuki M. Kaaoka A. Makino K. Kakehi Analysis of the components of Paeonia radix by capillary zone electrophoresis J. Chromatogr., A 1990 515 653 658 (Pubitemid 20277976)
    • (1990) Journal of Chromatography , vol.515 , pp. 653-658
    • Honda, S.1    Suzuki, K.2    Kataoka, M.3    Makino, A.4    Kakehi, K.5
  • 20
    • 15944395560 scopus 로고    scopus 로고
    • Rapid determination of paeoniflorin and three sugars in radix paeoniae alba by capillary electrophoresis
    • DOI 10.2116/analsci.21.247
    • G. Chen L. Zhang P. Yang Rapid determination of Paeoniflorin and three sugars in Radix Paeoniae Alba by capillary electrophoresis Anal. Sci. 2005 21 247 251 (Pubitemid 40445899)
    • (2005) Analytical Sciences , vol.21 , Issue.3 , pp. 247-251
    • Chen, G.1    Zhang, L.2    Yang, P.3
  • 21
    • 33845278396 scopus 로고
    • Current-monitoring method for measuring the electroosmotic Flow rate in capillary zone electrophoresis
    • X. Huang M. J. Gordon R. N. Zare Current-monitoring method for measuring the electroosmotic Flow rate in capillary zone electrophoresis Anal. Chem. 1988 60 1837 1838
    • (1988) Anal. Chem. , vol.60 , pp. 1837-1838
    • Huang, X.1    Gordon, M.J.2    Zare, R.N.3
  • 22
    • 0038844046 scopus 로고    scopus 로고
    • A new method to measure electroosmotic flow mobility of capillary electrophoresis by abrupt change of current de-noising via wavelet transform
    • Q. F. Li X. Y. Zahng H. Y. Zhang X. G. Chen Z. D. Hu A new method to measure electroosmotic flow mobility of capillary electrophoresis by abrupt change of current de-noising via wavelet transform Chin. J. Chem. 2010 19 581 587
    • (2010) Chin. J. Chem. , vol.19 , pp. 581-587
    • Li, Q.F.1    Zahng, X.Y.2    Zhang, H.Y.3    Chen, X.G.4    Hu, Z.D.5
  • 23
    • 27244462024 scopus 로고
    • On-column sample concentration using field amplification in CZE
    • R.-L. Chien D. S. Burgi On-column sample concentration using field amplification in CZE Anal. Chem. 1992 64 489A 496A
    • (1992) Anal. Chem. , vol.64
    • Chien, R.-L.1    Burgi, D.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.