메뉴 건너뛰기




Volumn 9, Issue 1, 2011, Pages 47-51

Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BREAST CANCER; CLINICAL PRACTICE; CONTROLLED STUDY; DATA BASE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; FEMALE; HUMAN; HUMAN EXPERIMENT; LYMPHEDEMA; NORMAL HUMAN; PRIORITY JOURNAL;

EID: 79952926473     PISSN: 15396851     EISSN: None     Source Type: Journal    
DOI: 10.1089/lrb.2010.0014     Document Type: Article
Times cited : (123)

References (19)
  • 1
    • 0026476408 scopus 로고
    • Multifrequency bioelectrical impedance augments the diagnosis and management of lymphedema in post-mastectomy patients
    • Ward LC, Bunce I, Cornish BH, et al. Multifrequency bioelectrical impedance augments the diagnosis and management of lymphedema in post-mastectomy patients. Eur J Clin Invest 1992;22:751-754.
    • (1992) Eur J Clin Invest , vol.22 , pp. 751-754
    • Ward, L.C.1    Bunce, I.2    Cornish, B.H.3
  • 3
    • 78650759740 scopus 로고    scopus 로고
    • Preoperative assessment enables the early detection and successful treatment of lymphedema
    • Schonholz S. Preoperative assessment enables the early detection and successful treatment of lymphedema. Cancer 2009;115:90-910.
    • (2009) Cancer , vol.115 , pp. 90-910
    • Schonholz, S.1
  • 4
    • 69049113376 scopus 로고    scopus 로고
    • Single frequency versus bioimpedance spectroscopy for the assessment of lymphedema
    • York SL, Ward LC, Czerniec S, et al. Single frequency versus bioimpedance spectroscopy for the assessment of lymphedema. Breast Cancer Res Treat 2009;117:177-182.
    • (2009) Breast Cancer Res Treat , vol.117 , pp. 177-182
    • York, S.L.1    Ward, L.C.2    Czerniec, S.3
  • 5
    • 0032796823 scopus 로고    scopus 로고
    • Optimizing electrode sites for segmental bioimpedance measurements
    • DOI 10.1088/0967-3334/20/3/302, PII S0967333499991062
    • Cornish BH, Jacobs A, Thomas BJ, et al. Optimizing electrode sites for segmental bioimpedance measurements Physiol Meas 1999;20:241-250. (Pubitemid 29399836)
    • (1999) Physiological Measurement , vol.20 , Issue.3 , pp. 241-250
    • Cornish, B.H.1    Jacobs, A.2    Thomas, B.J.3    Ward, L.C.4
  • 6
    • 67651034162 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis for early detection of lymphoedema
    • In: Weissleder H Schuchhardt C eds., 4th edn. Essen: Viavital Verlag Gmbh Publ.
    • Ward LC, Kilbreath SL, Cornish BH. Bioelectrical impedance analysis for early detection of lymphoedema. In: Weissleder H, Schuchhardt C eds. Lymphedema Diagnosis and Therapy. 4th edn. Essen: Viavital Verlag Gmbh Publ.; 2008; pp 502-517.
    • (2008) Lymphedema Diagnosis and Therapy , pp. 502-517
    • Ward, L.C.1    Kilbreath, S.L.2    Cornish, B.H.3
  • 7
    • 33645799245 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis: Proven utility in lymphedema risk assessment and therapeutic monitoring
    • Ward LC. Bioelectrical impedance analysis: Proven utility in lymphedema risk assessment and therapeutic monitoring. Lymphat Res Biol 2006;4:51-56.
    • (2006) Lymphat Res Biol , vol.4 , pp. 51-56
    • Ward, L.C.1
  • 8
    • 33645826516 scopus 로고    scopus 로고
    • Bioimpedance analysis: Scientific background
    • Cornish BH. Bioimpedance analysis: Scientific background. Lymphat Res Biol 2006;4:47-50.
    • (2006) Lymphat Res Biol , vol.4 , pp. 47-50
    • Cornish, B.H.1
  • 10
    • 79952951506 scopus 로고    scopus 로고
    • Inter-instrument comparison of bioimpedance spectroscopic analysers
    • Ward LC. Inter-instrument comparison of bioimpedance spectroscopic analysers. The Open Medical Device J 2009; 1:3-10.
    • (2009) The Open Medical Device J , vol.1 , pp. 3-10
    • Ward, L.C.1
  • 11
    • 0031806340 scopus 로고    scopus 로고
    • Data analysis in multiple-frequency bioelectrical impedance analysis
    • DOI 10.1088/0967-3334/19/2/014, PII S0967333498874297
    • Ward LC, Cornish BH. Data analysis in multiple frequency bioelectrical impedance analysis. Physiol Meas 1998;19:275-283. (Pubitemid 28247617)
    • (1998) Physiological Measurement , vol.19 , Issue.2 , pp. 275-283
    • Cornish, B.H.1    Ward, L.C.2
  • 12
    • 70349575987 scopus 로고    scopus 로고
    • Quantitative bioimpedance spectroscopy for the assessment of lymphoedema
    • Ward LC, Czerniec SA, Kilbreath SL. Quantitative bioimpedance spectroscopy for the assessment of lymphoedema. Breast Cancer Res Treat 2009;117:541-547.
    • (2009) Breast Cancer Res Treat , vol.117 , pp. 541-547
    • Ward, L.C.1    Czerniec, S.A.2    Kilbreath, S.L.3
  • 13
    • 0004252445 scopus 로고    scopus 로고
    • 4th edn Prentice Hall Inc, New Jersey
    • Zar JH. Biostatistical Analysis. 4th edn Prentice Hall Inc, New Jersey, 1999; pp.86-89.
    • (1999) Biostatistical Analysis , pp. 86-89
    • Zar, J.H.1
  • 14
    • 62949135980 scopus 로고    scopus 로고
    • Bioelectrical impedance for detecting upper limb lymphedema in nonlaboratory settings
    • Ridner SH, Dietrich MS, Deng J, et al. Bioelectrical impedance for detecting upper limb lymphedema in nonlaboratory settings. Lymphat Res Biol 2009;7:11-15.
    • (2009) Lymphat Res Biol , vol.7 , pp. 11-15
    • Ridner, S.H.1    Dietrich, M.S.2    Deng, J.3
  • 15
    • 79958199593 scopus 로고    scopus 로고
    • Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
    • DOI 10.1007/s00520-010-0896-8
    • Czerniec SA, Ward LC, Lee M-J, et al. Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy. Support Care Cancer 2010; DOI 10.1007/s00520-010-0896-8.
    • (2010) Support Care Cancer
    • Czerniec, S.A.1    Ward, L.C.2    Lee, M-.J.3
  • 16
    • 44349098249 scopus 로고    scopus 로고
    • Lymphedema secondary to breast cancer: How choice of measure influences diagnosis, prevalence, and identifiable risk factors
    • Hayes S, Janda M, Cornish B, et al. Lymphedema secondary to breast cancer: how choice of measure influences diagnosis, prevalence, and identifiable risk factors. Lymphology 2008;41:18-28. (Pubitemid 351747151)
    • (2008) Lymphology , vol.41 , Issue.1 , pp. 18-28
    • Hayes, S.1    Janda, M.2    Cornish, B.3    Battistutta, D.4    Newman, B.5
  • 17
    • 77951298638 scopus 로고    scopus 로고
    • Early detection of lymphoedema: Is BIS ready for prime time as the gold standard measure?
    • Ward LC. Early detection of lymphoedema: Is BIS ready for prime time as the gold standard measure? J Lymphoedema 2009;4:52-56.
    • (2009) J Lymphoedema , vol.4 , pp. 52-56
    • Ward, L.C.1
  • 19
    • 0026091980 scopus 로고
    • Relative expansion of extracellular fluid in obese vs nonobese women
    • Waki M, Kral JG, Mazariegos M, et al. Relative expansion of extracellular fluid in obese vs nonobese women. Am J Physiol 1991;261:E199-E203.
    • (1991) Am J Physiol , vol.261
    • Waki, M.1    Kral, J.G.2    Mazariegos, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.