메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Denoising and feature extraction in pd based cable condition monitoring systems

Author keywords

V N pattern; Decision tree; Medium voltage cable; On line monitoring data; Partial discharge; SGWT

Indexed keywords

AGED CABLE; CABLE INSULATION; CONDITION MONITORING SYSTEMS; DATA DE-NOISING; DE-NOISING; DE-NOISING TECHNIQUES; FEATURE EXTRACTION TECHNIQUES; INSULATION FAULT; MEDIUM VOLTAGE CABLES; ON-LINE MONITORING DATA; ON-LINE PARTIAL DISCHARGE; PD MONITORING; PD PATTERN; PD PULSE; POWER LINE CARRIER COMMUNICATION; RF NOISE; SECOND GENERATION WAVELET TRANSFORM; SGWT; SIGNAL CLASSIFICATION; SWITCHING PULSE;

EID: 79952925519     PISSN: 00849162     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CEIDP.2010.5723938     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 3
    • 79952981780 scopus 로고    scopus 로고
    • Private communication, Director of IPEC Ltd
    • Private communication, Director of IPEC Ltd.
  • 5
    • 0036505569 scopus 로고    scopus 로고
    • Automated Wavelet Selection and Thresholding for PD Detection
    • March/April
    • X. Ma, C. Zhou and I.J. Kemp: "Automated Wavelet Selection and Thresholding for PD Detection", IEEE Insulation Magazine, Vol. 18, No. 2, March/April, 2002.
    • (2002) IEEE Insulation Magazine , vol.18 , Issue.2
    • Ma, X.1    Zhou, C.2    Kemp, I.J.3
  • 6
    • 0036613463 scopus 로고    scopus 로고
    • Interpretation of Wavelet Analysis and Its Application in Partial Discharge Detection
    • June
    • X. Ma, C. Zhou, I. J. Kemp, "Interpretation of Wavelet Analysis and Its Application in Partial Discharge Detection", IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 19, No. 3, June 2002
    • (2002) IEEE Transactions on Dielectrics and Electrical Insulation , vol.19 , Issue.3
    • Ma, X.1    Zhou, C.2    Kemp, I.J.3
  • 7
    • 22744458250 scopus 로고    scopus 로고
    • An improved Methodology for Application of Wavelet Transform to Partial Discharge Measurement Denoising
    • March
    • X. Zhou, C. Zhou, I. J. Kemp, "An improved Methodology for Application of Wavelet Transform to Partial Discharge Measurement Denoising", IEEE Trans. Dielectrics and Electrical Insulation, Vol. 20, No. 2, March, 2005.
    • (2005) IEEE Trans. Dielectrics and Electrical Insulation , vol.20 , Issue.2
    • Zhou, X.1    Zhou, C.2    Kemp, I.J.3
  • 10
    • 0023829150 scopus 로고
    • Partial Discharge Measurement and Interpretation
    • May/June
    • David A. Nattrass: "Partial Discharge Measurement and Interpretation", IEEE Insulation Magazine, Vol. 4, No. 3, May/June, 1988.
    • (1988) IEEE Insulation Magazine , vol.4 , Issue.3
    • Nattrass, D.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.