메뉴 건너뛰기




Volumn 18, Issue 1, 2011, Pages 46-49

Capillary refill time: A study of interobserver reliability among nurses and nurse assistants

Author keywords

Capillary refill time; Interobserver reliability; Kappa; Medical admission unit; Vital signs

Indexed keywords

ADULT; AGED; ARTERIAL OXYGEN TENSION; ARTICLE; BODY TEMPERATURE; CAPILLARY REFILL TIME; CLINICAL ARTICLE; FEMALE; HUMAN; INDEX FINGER; MALE; NURSE; OBSERVER VARIATION; PERIPHERAL CIRCULATION; PRIORITY JOURNAL; SYSTOLIC BLOOD PRESSURE; BLOOD FLOW; BLOOD PRESSURE; CAPILLARY; CARDIOVASCULAR NURSING; CARDIOVASCULAR SYSTEM EXAMINATION; FINGER; MIDDLE AGED; NURSING ASSESSMENT; PHYSIOLOGY; PREDICTIVE VALUE; PROCEDURES; VASCULARIZATION; VERY ELDERLY;

EID: 79952902294     PISSN: 09699546     EISSN: None     Source Type: Journal    
DOI: 10.1097/MEJ.0b013e32833b4fba     Document Type: Article
Times cited : (29)

References (18)
  • 1
    • 50349118808 scopus 로고
    • The internal state of the severely wounded man on entry to the most forward hospital
    • Beecher HK, Semeone FA, Burnett CH. The internal state of the severely wounded man on entry to the most forward hospital. Surgery 1947; 22:627-681.
    • (1947) Surgery , vol.22 , pp. 627-681
    • Beecher, H.K.1    Semeone, F.A.2    Burnett, C.H.3
  • 3
    • 61749085129 scopus 로고    scopus 로고
    • A multidisciplinary survey on capillary refill time: Inconsistent performance and interpretation of a common clinical test
    • Lobos AT, Menon K. A multidisciplinary survey on capillary refill time: inconsistent performance and interpretation of a common clinical test. Pediatr Crit Care Med 2008; 9:386-391.
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 386-391
    • Lobos, A.T.1    Menon, K.2
  • 6
    • 0027500989 scopus 로고
    • Effect of ambient temperature on capillary refill in healthy children
    • Gorelick MH, Shaw KN, Baker MD. Effect of ambient temperature on capillary refill in healthy children. Pediatrics 1993; 92:699-702. (Pubitemid 23318992)
    • (1993) Pediatrics , vol.92 , Issue.5 , pp. 699-702
    • Gorelick, M.H.1    Shaw, K.N.2    Baker, M.D.3
  • 7
    • 0033020023 scopus 로고    scopus 로고
    • Capillary refill time in the hands and feet of normal newborn infants
    • Raju NV, Maisels MJ, Kring E, Schwarz-Warner L. Capillary refill time in the hands and feet of normal newborn infants. Clin Pediatr (Phila) 1999; 38:139-144. (Pubitemid 29135841)
    • (1999) Clinical Pediatrics , vol.38 , Issue.3 , pp. 139-144
    • Raju, N.V.1    Maisels, M.J.2    Kring, E.3    Schwarz-Warner, L.4
  • 8
    • 0027495131 scopus 로고
    • Capillary refill: Is it a useful clinical sign?
    • Baraff LJ. Capillary refill: is it a useful clinical sign? Pediatrics 1993; 92:723-724. (Pubitemid 23319001)
    • (1993) Pediatrics , vol.92 , Issue.5 , pp. 723-724
    • Baraff, L.J.1
  • 9
    • 0023794572 scopus 로고
    • Defining normal capillary refill: Variation with age, sex, and temperature
    • Schriger DL, Baraff L. Defining normal capillary refill: variation with age, sex, and temperature. Ann Emerg Med 1988; 17:932-935.
    • (1988) Ann Emerg Med , vol.17 , pp. 932-935
    • Schriger, D.L.1    Baraff, L.2
  • 10
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977; 33:159-174. (Pubitemid 8054849)
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 11
    • 36849022098 scopus 로고    scopus 로고
    • Impact of patient and environmental factors on capillary refill time in adults
    • DOI 10.1016/j.ajem.2007.06.026, PII S0735675707004500
    • Anderson B, Kelly AM, Kerr D, Clooney M, Jolley D. Impact of patient and environmental factors on capillary refill time in adults. Am J Emerg Med 2008; 26:62-65. (Pubitemid 350235849)
    • (2008) American Journal of Emergency Medicine , vol.26 , Issue.1 , pp. 62-65
    • Anderson, B.1    Kelly, A.-M.2    Kerr, D.3    Clooney, M.4    Jolley, D.5
  • 12
    • 0031953168 scopus 로고    scopus 로고
    • Capillary refilling time in newborns - Optimal pressing time, sites of testing and normal values
    • DOI 10.1080/08035259850157372
    • Strozik KS, Pieper CH, Cools F. Capillary refilling time in newborns-optimal pressing time, sites of testing and normal values. Acta Paediatr 1998; 87:310-312. (Pubitemid 28134271)
    • (1998) Acta Paediatrica, International Journal of Paediatrics , vol.87 , Issue.3 , pp. 310-312
    • Strozik, K.S.1    Pieper, C.H.2    Cools, F.3
  • 13
    • 0027980122 scopus 로고
    • Adverse lighting condition effects on the assessment of capillary refill
    • DOI 10.1016/0735-6757(94)90196-1
    • Brown LH, Prasad NH, Whitley TW. Adverse lighting condition effects on the assessment of capillary refill. Am J Emerg Med 1994; 12:46-47. (Pubitemid 24055923)
    • (1994) American Journal of Emergency Medicine , vol.12 , Issue.1 , pp. 46-47
    • Brown, L.H.1    Prasad, N.H.2    Whitley, T.W.3
  • 14
    • 0025796876 scopus 로고
    • Capillary refill-is it a useful predictor of hypovolemic states?
    • Schriger DL, Baraff LJ. Capillary refill-is it a useful predictor of hypovolemic states? Ann Emerg Med 1991; 20:601-605.
    • (1991) Ann Emerg Med , vol.20 , pp. 601-605
    • Schriger, D.L.1    Baraff, L.J.2
  • 15
    • 0033577337 scopus 로고    scopus 로고
    • The rational clinical examination. Is this patient hypovolemic?
    • McGee S, Abernethy WB III, Simel DL. The rational clinical examination. Is this patient hypovolemic? JAMA 1999; 281:1022-1029.
    • (1999) JAMA , vol.281 , pp. 1022-1029
    • McGee, S.1    Abernethy III, W.B.2    Simel, D.L.3
  • 16
    • 2342574462 scopus 로고    scopus 로고
    • Capillary refill: Prognostic value in Kenyan children
    • Pamba A, Maitland K. Capillary refill: prognostic value in Kenyan children. Arch Dis Child 2004; 89:950-955.
    • (2004) Arch Dis Child , vol.89 , pp. 950-955
    • Pamba, A.1    Maitland, K.2
  • 18
    • 4644230028 scopus 로고    scopus 로고
    • Is measurement of capillary refill time useful as part of the initial assessment of children?
    • Leonard PA, Beattie TF. Is measurement of capillary refill time useful as part of the initial assessment of children? Eur J Emerg Med 2004; 11:158-163.
    • (2004) Eur J Emerg Med , vol.11 , pp. 158-163
    • Leonard, P.A.1    Beattie, T.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.