메뉴 건너뛰기




Volumn 36, Issue 3, 2011, Pages 230-235

Assessing angulation on digital images of radiographs of fractures of the distal radius: Visual estimation versus computer software measurement

Author keywords

Angles; Digitalized; Estimation; X rays

Indexed keywords

ARTICLE; CLINICAL COMPETENCE; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; EMERGENCY HEALTH SERVICE; FEMALE; HUMAN; MALE; MORPHOMETRICS; OBSERVER VARIATION; ORTHOPEDICS; RADIOGRAPHY; RADIUS FRACTURE; REPRODUCIBILITY;

EID: 79952835605     PISSN: 17531934     EISSN: 20436289     Source Type: Journal    
DOI: 10.1177/1753193410391361     Document Type: Article
Times cited : (8)

References (11)
  • 2
    • 0036939008 scopus 로고    scopus 로고
    • The evaluation of a new digital semi-automated system for the radiological assessment of distal radial fractures
    • DOI 10.1007/s00256-002-0526-8
    • Grainger AJ, Duryea J, Elliott JM et al. The evaluation of a new digital semi-automated system for the radiological assessment of distal radial fractures. Skeletal Radiol. 2002, 31: 457-63. (Pubitemid 36067545)
    • (2002) Skeletal Radiology , vol.31 , Issue.8 , pp. 457-463
    • Grainger, A.J.1    Duryea, J.2    Elliott, J.M.3    Genant, H.K.4
  • 4
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977, 33: 159-74. (Pubitemid 8054849)
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 5
    • 0023792951 scopus 로고
    • Colles fracture: Does the anatomical result affect the final function?
    • McQueen M, Caspers J. Colles fracture: Does the anatomical result affect the final function? J Bone Joint Surg Br. 1988, 70: 649-51.
    • (1988) J Bone Joint Surg Br. , vol.70 , pp. 649-651
    • McQueen, M.1    Caspers, J.2
  • 6
    • 0036692905 scopus 로고    scopus 로고
    • Visual estimation of finger angles: Do we need goniometers?
    • Rose V, Nduka CC, Pereira JA et al. Visual estimation of finger angles: do we need goniometers? J Hand Surg Br. 2002, 27: 382-4.
    • (2002) J Hand Surg Br. , vol.27 , pp. 382-384
    • Rose, V.1    Nduka, C.C.2    Pereira, J.A.3
  • 7
    • 68349096489 scopus 로고    scopus 로고
    • Visual and computer software- aided estimates of Dupuytren's contractures: Correlation with clinical goniometric measurements
    • Smith RP, Dias JJ, Ullah A et al. Visual and computer software- aided estimates of Dupuytren's contractures: correlation with clinical goniometric measurements. Ann R Coll Surg Engl. 2009, 91: 296-300.
    • (2009) Ann R Coll Surg Engl. , vol.91 , pp. 296-300
    • Smith, R.P.1    Dias, J.J.2    Ullah, A.3
  • 8
    • 46249123403 scopus 로고    scopus 로고
    • The reliability of measurements taken from computer-stored digitalised x-rays of acute distal radius fractures
    • DOI 10.1177/1753193407087509
    • Thomason K, Smith KL. The reliability of measurements taken from computer-stored digitalised radiographs of acute distal radius fractures. J Hand Surg Eur. 2008, 33: 369-72. (Pubitemid 351911218)
    • (2008) Journal of Hand Surgery: European Volume , vol.33 , Issue.3 , pp. 369-372
    • Thomason, K.1    Smith, K.L.2
  • 9
    • 0028266946 scopus 로고
    • Factors affecting functional outcome of displaced intra-articular distal radius fractures
    • Trumble TE, Schmitt SR, Vedder NB. Factors affecting the functional outcome of displaced intra-articular distal radial fractures. J Hand Surgery Am. 1994, 19: 325-40. (Pubitemid 24105129)
    • (1994) Journal of Hand Surgery , vol.19 , Issue.2 , pp. 325-340
    • Trumble, T.E.1    Schmitt, S.R.2    Vedder, N.B.3
  • 10
    • 0019412674 scopus 로고
    • Colles' fracture. How should its displacement be measured and how should it be immobilized?
    • Van der Linden W, Ericson R. Colles' fracture. How should its displacement be measured and how should it be immobilized? J Bone Joint Surg Am. 1981, 63: 1285-8. (Pubitemid 11022303)
    • (1981) Journal of Bone and Joint Surgery - Series A , vol.63 , Issue.8 , pp. 1285-1288
    • Van Der Linden, W.1    Ericson, R.2
  • 11
    • 0026058416 scopus 로고
    • Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting
    • Watkins MA, Riddle DL, Lamb RL et al. Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting. Phys Ther. 1991, 71: 90-7.
    • (1991) Phys Ther. , vol.71 , pp. 90-97
    • Watkins, M.A.1    Riddle, D.L.2    Lamb, R.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.