메뉴 건너뛰기




Volumn 6, Issue 3, 2010, Pages 380-387

Intravascular ultrasound, angioscopic and histopathological characterisation of heterogeneous patterns of restenosis after sirolimus-eluting stent implantation: Insights into potential "thromborestenosis" phenomenon

Author keywords

Atherectomy; Bare metal stent; Sirolimus eluting stent

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; COLLAGEN; FIBRIN; RAPAMYCIN; TICLOPIDINE; IMMUNOSUPPRESSIVE AGENT;

EID: 79952778553     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV6I3A63     Document Type: Article
Times cited : (34)

References (24)
  • 1
    • 0035928843 scopus 로고    scopus 로고
    • Bench to bedside: The development of rapamycin and its application to stent restenosis
    • Marx SO, Marks AR. Bench to bedside: the development of rapamycin and its application to stent restenosis. Circulation. 2001;104:852-855. (Pubitemid 32778031)
    • (2001) Circulation , vol.104 , Issue.8 , pp. 852-855
    • Marx, S.O.1    Marks, A.R.2
  • 4
    • 0035176865 scopus 로고    scopus 로고
    • Coronary restenosis elimination with a sirolimus eluting stent: First European human experience with 6-month angiographic and intravascular ultrasonic follow-up
    • DOI 10.1053/euhj.2001.2892
    • Rensing BJ, Vos J, Smits PC, Foley DP, van den Brand MJ, van der Giessen WJ, de Feijter PJ, Serruys PW. Coronary restenosis elimination with a sirolimus eluting stent: first European human experience with 6-month angiographic and intravascular ultrasonic follow-up. Eur Heart J. 2001;22:2125-2130. (Pubitemid 33091454)
    • (2001) European Heart Journal , vol.22 , Issue.22 , pp. 2125-2130
    • Rensing, B.J.1    Vos, J.2    Smits, P.C.3    Foley, D.P.4    Van Den, B.M.J.B.M.5    Van Der, G.W.J.6    De Feijter, P.J.7    Serruys, P.W.8
  • 6
    • 0037072467 scopus 로고    scopus 로고
    • Intravascular ultrasound findings in the multi-center, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial
    • Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, Guagliumi G, Wijns W, Lindeboom WK, Ligthart J, de Feyter PJ, Morice MC. Intravascular ultrasound findings in the multi-center, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation. 2002;106:798-803.
    • (2002) Circulation , vol.106 , pp. 798-803
    • Serruys, P.W.1    Degertekin, M.2    Tanabe, K.3    Abizaid, A.4    Sousa, J.E.5    Colombo, A.6    Guagliumi, G.7    Wijns, W.8    Lindeboom, W.K.9    Ligthart, J.10    De Feyter, P.J.11    Morice, M.C.12
  • 11
    • 0037303940 scopus 로고    scopus 로고
    • Drug eluting stents: Are human and animal studies comparable?
    • Virmani R, Kolodgie FD, Farb A, Lafont A. Drug eluting stents: are human and animal studies comparable? Heart. 2003;89:133-138.
    • (2003) Heart , vol.89 , pp. 133-138
    • Virmani, R.1    Kolodgie, F.D.2    Farb, A.3    Lafont, A.4
  • 13
    • 0037432294 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Sirolimus-eluting stent implanted in human coronary artery for 16 months: Pathological findings
    • Guagliumi G, Farb A, Musumeci G, Valsecchi O, Tespili M, Motta T, Virmani R. Images in cardiovascular medicine. Sirolimus-eluting stent implanted in human coronary artery for 16 months: pathological findings. Circulation. 2003;107:1340-1341.
    • (2003) Circulation , vol.107 , pp. 1340-1341
    • Guagliumi, G.1    Farb, A.2    Musumeci, G.3    Valsecchi, O.4    Tespili, M.5    Motta, T.6    Virmani, R.7
  • 22
    • 33748773896 scopus 로고    scopus 로고
    • Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation
    • DOI 10.1093/eurheartj/ehl181
    • Takano M, Ohba T, Inami S, Seimiya K, Sakai S, Mizuno K. Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation. Eur Heart J. 2006;27:2189-2195. (Pubitemid 44412833)
    • (2006) European Heart Journal , vol.27 , Issue.18 , pp. 2189-2195
    • Takano, M.1    Ohba, T.2    Inami, S.3    Seimiya, K.4    Sakai, S.5    Mizuno, K.6
  • 23
    • 34548119861 scopus 로고    scopus 로고
    • Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: Comparison with bare-metal stents
    • DOI 10.1161/CIRCULATIONAHA.105.609057, PII 0000301720070821000008
    • Awata M, Kotani J, Uematsu M, Morozumi T, Watanabe T, Onishi T, Iida O, Sera F, Nanto S, Hori M, Nagata S. Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents. Circulation. 2007;116:910-916. (Pubitemid 47300915)
    • (2007) Circulation , vol.116 , Issue.8 , pp. 910-916
    • Awata, M.1    Kotani, J.-I.2    Uematsu, M.3    Morozumi, T.4    Watanabe, T.5    Onishi, T.6    Iida, O.7    Sera, F.8    Nanto, S.9    Hori, M.10    Nagata, S.11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.