Comparison of air-charged and water-filled urodynamic pressure measurement catheters

Author keywords

Air charged; Catheter; Frequency response; Pressure; Urodynamics; Water filled

Indexed keywords

ARTICLE; ARTIFACT; BLADDER CATHETERIZATION; CLINICAL PRACTICE; HYDROSTATIC PRESSURE; URODYNAMICS;

EID: 79952775042     PISSN: 07332467     EISSN: 15206777     Source Type: Journal    
DOI: 10.1002/nau.20991     Document Type: Article
Times cited : (57)

References (12)
  • 1
    • 64249133291 scopus 로고    scopus 로고
    • Trends in stress urinary incontinence inpatient procedures in the United States, 1979-2004
    • Oliphant SS, Wang L, Bunker CH, et al. Trends in stress urinary incontinence inpatient procedures in the United States, 1979-2004. Am J Obstet Gynecol 2009;200:521.e1-6.
    • (2009) Am J Obstet Gynecol , vol.200
    • Oliphant, S.S.1    Wang, L.2    Bunker, C.H.3
  • 2
    • 77950986753 scopus 로고    scopus 로고
    • Treatment options for male stress urinary incontinence
    • Sandhu JS. Treatment options for male stress urinary incontinence. Nature Rev Urol 2010;7:222-8.
    • (2010) Nature Rev Urol , vol.7 , pp. 222-228
    • Sandhu, J.S.1
  • 3
    • 0036102848 scopus 로고    scopus 로고
    • Good urodynamic practices: Uroflowmetry, filling cystometry, and pressure-flow studies
    • Schafer W, Abrams P, Liao L, et al. Good urodynamic practices: Uroflowmetry, filling cystometry, and pressure-flow studies. Neurourol Urodyn 2002;21:261-74.
    • (2002) Neurourol Urodyn , vol.21 , pp. 261-274
    • Schafer, W.1    Abrams, P.2    Liao, L.3
  • 4
    • 0023310750 scopus 로고
    • Urodynamic equipment: Technical aspects. Produced by the International Continence Society working party on urodynamic equipment
    • Rowan D, James ED, Kramer AE, et al. Urodynamic equipment: Technical aspects. Produced by the International Continence Society working party on urodynamic equipment. J Med Eng Technol 1987;11:57-64.
    • (1987) J Med Eng Technol , vol.11 , pp. 57-64
    • Rowan, D.1    James, E.D.2    Kramer, A.E.3
  • 5
    • 48649089302 scopus 로고    scopus 로고
    • Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: A prospective single-blind, randomized trial
    • Zehnder P, Roth B, Burkhard FD, et al. Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: A prospective single-blind, randomized trial. J Urol 2008;180:1017.
    • (2008) J Urol , vol.180 , pp. 1017
    • Zehnder, P.1    Roth, B.2    Burkhard, F.D.3
  • 7
    • 0016936661 scopus 로고
    • Dynamic calibration of manometer systems
    • Hok B. Dynamic calibration of manometer systems. Med Biol Eng 1976;14:193-8.
    • (1976) Med Biol Eng , vol.14 , pp. 193-198
    • Hok, B.1
  • 9
    • 76049122858 scopus 로고    scopus 로고
    • Executive summary: The International Consultation on Incontinence 2008 - Committee on "Dynamic Testing", for urinary incontinence and for fecal incontinence. Part 1: Innovations in urodynamic techniques and urodynamic testing for signs and symptoms of urinary incontinence in female patients
    • Rosier PF, Gajewski JB, Sand PK, et al. Executive summary: The International Consultation on Incontinence 2008 - Committee on "Dynamic Testing", for urinary incontinence and for fecal incontinence. Part 1: Innovations in urodynamic techniques and urodynamic testing for signs and symptoms of urinary incontinence in female patients. Neurourol Urodyn 2010;29:140-5.
    • (2010) Neurourol Urodyn , vol.29 , pp. 140-145
    • Rosier, P.F.1    Gajewski, J.B.2    Sand, P.K.3
  • 10
    • 0023786403 scopus 로고
    • Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method
    • Schwid HA. Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method. J Clin Monit Comput 1988;4:181-5.
    • (1988) J Clin Monit Comput , vol.4 , pp. 181-185
    • Schwid, H.A.1
  • 11
    • 0014833788 scopus 로고
    • Damped and undamped frequency responses of underdamped catheter manometer systems
    • Shapiro GG, Krovetz LJ. Damped and undamped frequency responses of underdamped catheter manometer systems. Am Heart J 1970;80:226-36.
    • (1970) Am Heart J , vol.80 , pp. 226-236
    • Shapiro, G.G.1    Krovetz, L.J.2
  • 12
    • 0035062094 scopus 로고    scopus 로고
    • Mechanisms of female urinary continence under stress: Frequency spectrum analysis
    • DOI 10.1016/S0021-9290(01)00006-9, PII S0021929001000069
    • Kim KJ, Jurnalov CD, Ham SY, et al. Mechanisms of female urinary continence under stress: Frequency spectrum analysis. J Biomech 2001;34:687-91. (Pubitemid 32328257)
    • (2001) Journal of Biomechanics , vol.34 , Issue.5 , pp. 687-691
    • Kim, K.-J.1    Jurnalov, C.D.2    Ham, S.-Y.3    Webb, M.J.4    An, K.-N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.