메뉴 건너뛰기




Volumn 122, Issue 6, 2011, Pages 1091-1097

Neonatal seizure recognition - Comparative study of continuous-amplitude integrated EEG versus short conventional EEG recordings

Author keywords

Amplitude integrated electroencephalography; Conventional electroencephalography; Neonate; Seizure

Indexed keywords

ANTICONVULSIVE AGENT;

EID: 79952727136     PISSN: 13882457     EISSN: 18728952     Source Type: Journal    
DOI: 10.1016/j.clinph.2010.09.028     Document Type: Article
Times cited : (61)

References (16)
  • 1
    • 0026052643 scopus 로고
    • Status epilepticus: clinical experience with two special devices for continuous cerebral monitoring
    • Altfullah I., Asaikar S., Torres F. Status epilepticus: clinical experience with two special devices for continuous cerebral monitoring. Acta Neurol Scand 1991, 84:374-381.
    • (1991) Acta Neurol Scand , vol.84 , pp. 374-381
    • Altfullah, I.1    Asaikar, S.2    Torres, F.3
  • 2
    • 70449522387 scopus 로고    scopus 로고
    • Detection of subclinical electroencephalographic seizure patterns with multichannel amplitude-integrated EEG in full-term neonates
    • Bourez-Swart M., van Rooij L., Rizzo C., de Vries L., Toet M., Gebbink T., Ezendam A., van Huffelen A. Detection of subclinical electroencephalographic seizure patterns with multichannel amplitude-integrated EEG in full-term neonates. Clin Neurophysiol 2009, 120:1916-1922.
    • (2009) Clin Neurophysiol , vol.120 , pp. 1916-1922
    • Bourez-Swart, M.1    van Rooij, L.2    Rizzo, C.3    de Vries, L.4    Toet, M.5    Gebbink, T.6    Ezendam, A.7    van Huffelen, A.8
  • 3
    • 0034119856 scopus 로고    scopus 로고
    • Paroxysmal non-epileptic events in children: a retrospective study over a period of 10 years
    • Bye A.M., Kok D.J., Ferenschild F.T., Vles J.S. Paroxysmal non-epileptic events in children: a retrospective study over a period of 10 years. J Paediatr Child Health 2000, 36:244-248.
    • (2000) J Paediatr Child Health , vol.36 , pp. 244-248
    • Bye, A.M.1    Kok, D.J.2    Ferenschild, F.T.3    Vles, J.S.4
  • 4
    • 0023920682 scopus 로고
    • Occult neonatal seizures
    • Clancy R., Legido A. Occult neonatal seizures. Epilepsia 1988, 29:256-261.
    • (1988) Epilepsia , vol.29 , pp. 256-261
    • Clancy, R.1    Legido, A.2
  • 5
    • 69249216499 scopus 로고    scopus 로고
    • Clinical neonatal seizures are independently associated with outcome in infants at risk for hypoxic-ischemic brain injury
    • Glass H.C., Glidden D., Jeremy R.J., Barkovich A.J., Ferriero D.M., Miller S.P. Clinical neonatal seizures are independently associated with outcome in infants at risk for hypoxic-ischemic brain injury. J Pediatr 2009, 155:318-323.
    • (2009) J Pediatr , vol.155 , pp. 318-323
    • Glass, H.C.1    Glidden, D.2    Jeremy, R.J.3    Barkovich, A.J.4    Ferriero, D.M.5    Miller, S.P.6
  • 6
    • 0030317076 scopus 로고    scopus 로고
    • Descriptive epidemiology of epilepsy: contributions of population-based studies from Rochester, Minnesota
    • Hauser W.A., Annegers J.F., Rocca W.A. Descriptive epidemiology of epilepsy: contributions of population-based studies from Rochester, Minnesota. Mayo Clin Proc 1996, 71:576-586.
    • (1996) Mayo Clin Proc , vol.71 , pp. 576-586
    • Hauser, W.A.1    Annegers, J.F.2    Rocca, W.A.3
  • 7
    • 33750524428 scopus 로고    scopus 로고
    • Continuous brain-function monitoring: state of the art in clinical practice
    • Hellstrom-Westas L., Rosen I. Continuous brain-function monitoring: state of the art in clinical practice. Semin Fetal Neonatal Med 2006, 11:503-511.
    • (2006) Semin Fetal Neonatal Med , vol.11 , pp. 503-511
    • Hellstrom-Westas, L.1    Rosen, I.2
  • 8
    • 0036206824 scopus 로고    scopus 로고
    • The clinical conundrum of neonatal seizures
    • Levene M. The clinical conundrum of neonatal seizures. Arch Dis Child Fetal Neonatal Ed 2002, 86:F75-F77.
    • (2002) Arch Dis Child Fetal Neonatal Ed , vol.86
    • Levene, M.1
  • 10
  • 11
    • 48949104208 scopus 로고    scopus 로고
    • Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants
    • Shah D., Mackay M., Lavery S., Watson S., Harvey S., Zempel J., Mathur A., Inder T. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics 2008, 121:1146-1154.
    • (2008) Pediatrics , vol.121 , pp. 1146-1154
    • Shah, D.1    Mackay, M.2    Lavery, S.3    Watson, S.4    Harvey, S.5    Zempel, J.6    Mathur, A.7    Inder, T.8
  • 12
    • 33644554149 scopus 로고    scopus 로고
    • Amplitude-integrated electroencephalography: a tool for monitoring silent seizures in neonates
    • Shany E., Khvatskin S., Golan A., Karplus M. Amplitude-integrated electroencephalography: a tool for monitoring silent seizures in neonates. Pediatr Neurol 2006, 34:194-199.
    • (2006) Pediatr Neurol , vol.34 , pp. 194-199
    • Shany, E.1    Khvatskin, S.2    Golan, A.3    Karplus, M.4
  • 13
    • 35148856609 scopus 로고    scopus 로고
    • Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection
    • Shellhaas R., Soaita A., Clancy R. Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection. Pediatrics 2007, 120:770-777.
    • (2007) Pediatrics , vol.120 , pp. 770-777
    • Shellhaas, R.1    Soaita, A.2    Clancy, R.3
  • 14
    • 0036247410 scopus 로고    scopus 로고
    • Comparison between simultaneously recorded amplitude-integrated electroencephalography (cerebral function monitor) and standard electroencephalography in neonates
    • Toet M., van der Meij W., de Vries L., Uiterwaal C., van Huffelen K. Comparison between simultaneously recorded amplitude-integrated electroencephalography (cerebral function monitor) and standard electroencephalography in neonates. Pediatrics 2002, 109:772-779.
    • (2002) Pediatrics , vol.109 , pp. 772-779
    • Toet, M.1    van der Meij, W.2    de Vries, L.3    Uiterwaal, C.4    van Huffelen, K.5
  • 16
    • 61849179301 scopus 로고    scopus 로고
    • Limitations of single-channel EEG on the forehead for neonatal seizure detection
    • Wusthoff C.J., Shellhaas R.A., Clancy R.R. Limitations of single-channel EEG on the forehead for neonatal seizure detection. J Perinatol 2009, 29:237-242.
    • (2009) J Perinatol , vol.29 , pp. 237-242
    • Wusthoff, C.J.1    Shellhaas, R.A.2    Clancy, R.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.