-
1
-
-
0014677132
-
Platelet preservation: Effect of storage temperature on maintenance of platelet viability-Deleterious effect of refrigerated storage
-
Murphy S., Gardner F.H. Platelet preservation: Effect of storage temperature on maintenance of platelet viability-Deleterious effect of refrigerated storage. New Engl J Med 1969, 280:1094-1098.
-
(1969)
New Engl J Med
, vol.280
, pp. 1094-1098
-
-
Murphy, S.1
Gardner, F.H.2
-
2
-
-
0014772314
-
Storage of platelet concentrates at 22°C
-
Murphy S., Sayar S.N., Gardner F.H. Storage of platelet concentrates at 22°C. Blood 1970, 35:549-557.
-
(1970)
Blood
, vol.35
, pp. 549-557
-
-
Murphy, S.1
Sayar, S.N.2
Gardner, F.H.3
-
3
-
-
0013568629
-
The transfusion of human blood platelets: With a note on the transfusion of granulocytes
-
Hirsch E.O., Gardner F.H. The transfusion of human blood platelets: With a note on the transfusion of granulocytes. J Lab Clin Med 1952, 39:556-569.
-
(1952)
J Lab Clin Med
, vol.39
, pp. 556-569
-
-
Hirsch, E.O.1
Gardner, F.H.2
-
4
-
-
76549175473
-
Response to transfusion of platelets pooled from multiple donors and the effects of various techniques of concentrating platelets
-
Levin R.H., Pert J.H., Freireich E.J. Response to transfusion of platelets pooled from multiple donors and the effects of various techniques of concentrating platelets. Transfusion 1965, 5:54-63.
-
(1965)
Transfusion
, vol.5
, pp. 54-63
-
-
Levin, R.H.1
Pert, J.H.2
Freireich, E.J.3
-
5
-
-
79952702272
-
A simple method for obtaining platelet concentrates free of aggregates
-
[Abstract]
-
Mourad N. A simple method for obtaining platelet concentrates free of aggregates. Transfusion 1968, 48:8. [Abstract].
-
(1968)
Transfusion
, vol.48
, pp. 8
-
-
Mourad, N.1
-
6
-
-
75949116463
-
Novel and unexpected clearance mechanisms for cold platelets
-
Rumjantseva V., Hoffmeister K.M. Novel and unexpected clearance mechanisms for cold platelets. Transfus Apher Sci 2010, 42:63-70.
-
(2010)
Transfus Apher Sci
, vol.42
, pp. 63-70
-
-
Rumjantseva, V.1
Hoffmeister, K.M.2
-
7
-
-
0842346520
-
Radiolabeling of PLTs to assess viability: A proposal for a standard
-
Murphy S. Radiolabeling of PLTs to assess viability: A proposal for a standard. Transfusion 2004, 44:131-133.
-
(2004)
Transfusion
, vol.44
, pp. 131-133
-
-
Murphy, S.1
-
8
-
-
0022743379
-
Polycythemia Vera Study Group: A historical perspective
-
Wasserman L.R. Polycythemia Vera Study Group: A historical perspective. Semin Hematol 1986, 23:183-187.
-
(1986)
Semin Hematol
, vol.23
, pp. 183-187
-
-
Wasserman, L.R.1
-
9
-
-
0015009416
-
Platelet storage at 22°C; metabolic, morphologic and functional studies
-
Murphy S., Gardner F.H. Platelet storage at 22°C; metabolic, morphologic and functional studies. J Clin Invest 1971, 50:370-377.
-
(1971)
J Clin Invest
, vol.50
, pp. 370-377
-
-
Murphy, S.1
Gardner, F.H.2
-
10
-
-
0016740931
-
Platelet storage at 22°C: Role of gas transport across plastic containers in maintenance of viability
-
Murphy S., Gardner F.H. Platelet storage at 22°C: Role of gas transport across plastic containers in maintenance of viability. Blood 1975, 46:209-218.
-
(1975)
Blood
, vol.46
, pp. 209-218
-
-
Murphy, S.1
Gardner, F.H.2
-
11
-
-
0017847829
-
Platelet storage at 22°C: Effect of type of agitation on morphology, viability, and function in vitro
-
Holme S., Vaidja K., Murphy S. Platelet storage at 22°C: Effect of type of agitation on morphology, viability, and function in vitro. Blood 1978, 52:425-435.
-
(1978)
Blood
, vol.52
, pp. 425-435
-
-
Holme, S.1
Vaidja, K.2
Murphy, S.3
-
12
-
-
0019956803
-
Improved storage of platelets for transfusion in a new container
-
Murphy S., Kahn R.A., Holme S., et al. Improved storage of platelets for transfusion in a new container. Blood 1982, 60:194-200.
-
(1982)
Blood
, vol.60
, pp. 194-200
-
-
Murphy, S.1
Kahn, R.A.2
Holme, S.3
-
13
-
-
0021320667
-
Paired comparison of the in vivo and in vitro results of storage of platelet concentrates in two containers
-
Murphy S., Holme S., Nelson E., et al. Paired comparison of the in vivo and in vitro results of storage of platelet concentrates in two containers. Transfusion 1984, 24:31-34.
-
(1984)
Transfusion
, vol.24
, pp. 31-34
-
-
Murphy, S.1
Holme, S.2
Nelson, E.3
-
14
-
-
0021807715
-
Extended storage of platelets in a new plastic container II. In vivo response to infusion of platelets stored for 5 days
-
Snyder E.L., Ezekowitz M., Aster R., et al. Extended storage of platelets in a new plastic container II. In vivo response to infusion of platelets stored for 5 days. Transfusion 1985, 25:209-214.
-
(1985)
Transfusion
, vol.25
, pp. 209-214
-
-
Snyder, E.L.1
Ezekowitz, M.2
Aster, R.3
-
15
-
-
0025718338
-
Concepts about current conditions for the preparation and storage of platelets
-
Moroff G., Holme S. Concepts about current conditions for the preparation and storage of platelets. Transfus Med Rev 1991, 5:48-59.
-
(1991)
Transfus Med Rev
, vol.5
, pp. 48-59
-
-
Moroff, G.1
Holme, S.2
-
16
-
-
0021209418
-
Platelet metabolism during storage of platelet concentrates at 22°C
-
Kilkson H., Holme S., Murphy S. Platelet metabolism during storage of platelet concentrates at 22°C. Blood 1984, 64:406-414.
-
(1984)
Blood
, vol.64
, pp. 406-414
-
-
Kilkson, H.1
Holme, S.2
Murphy, S.3
-
17
-
-
0023612255
-
Plasma free fatty acid metabolism during storage of platelet concentrates for transfusion
-
Cesar J., DiMinno G., Alam I., et al. Plasma free fatty acid metabolism during storage of platelet concentrates for transfusion. Transfusion 1987, 27:434-437.
-
(1987)
Transfusion
, vol.27
, pp. 434-437
-
-
Cesar, J.1
DiMinno, G.2
Alam, I.3
-
18
-
-
0026645939
-
Amino acid metabolism during platelet storage for transfusion
-
Murphy S., Munoz S., Parry-Billings M., et al. Amino acid metabolism during platelet storage for transfusion. Br J Haematol 1992, 81:585-590.
-
(1992)
Br J Haematol
, vol.81
, pp. 585-590
-
-
Murphy, S.1
Munoz, S.2
Parry-Billings, M.3
-
19
-
-
0026078939
-
Platelet storage in synthetic media lacking glucose and bicarbonate
-
Murphy S., Kagen L., Holme S., et al. Platelet storage in synthetic media lacking glucose and bicarbonate. Transfusion 1991, 31:16-20.
-
(1991)
Transfusion
, vol.31
, pp. 16-20
-
-
Murphy, S.1
Kagen, L.2
Holme, S.3
-
20
-
-
0026551876
-
Platelet quality after 15-day storage of platelet concentrates prepared from buffy coats and stored in a glucose-free crystalloid medium
-
Bertolini F., Rebulla P., Porretti L., Murphy S. Platelet quality after 15-day storage of platelet concentrates prepared from buffy coats and stored in a glucose-free crystalloid medium. Transfusion 1992, 32:9-16.
-
(1992)
Transfusion
, vol.32
, pp. 9-16
-
-
Bertolini, F.1
Rebulla, P.2
Porretti, L.3
Murphy, S.4
-
21
-
-
0026554513
-
Role of acetate during platelet storage in a synthetic medium
-
Bertolini F., Murphy S., Rebulla P., et al. Role of acetate during platelet storage in a synthetic medium. Transfusion 1992, 32:152-156.
-
(1992)
Transfusion
, vol.32
, pp. 152-156
-
-
Bertolini, F.1
Murphy, S.2
Rebulla, P.3
-
22
-
-
0028929437
-
The oxidation of exogenously added organic anions by platelets facilitates maintenance of pH during their storage for transfusion at 22°C
-
Murphy S. The oxidation of exogenously added organic anions by platelets facilitates maintenance of pH during their storage for transfusion at 22°C. Blood 1995, 85:1929-1935.
-
(1995)
Blood
, vol.85
, pp. 1929-1935
-
-
Murphy, S.1
-
23
-
-
0028886538
-
Platelet storage for transfusion in synthetic media: Further optimization of ingredients and definition of their roles
-
Murphy S., Shimizu T., Miropol J. Platelet storage for transfusion in synthetic media: Further optimization of ingredients and definition of their roles. Blood 1995, 86:3951-3960.
-
(1995)
Blood
, vol.86
, pp. 3951-3960
-
-
Murphy, S.1
Shimizu, T.2
Miropol, J.3
-
24
-
-
0018091218
-
Quantitative measurements of platelet shape by light transmission studies: Application to storage of platelets for transfusion
-
Holme S., Murphy S. Quantitative measurements of platelet shape by light transmission studies: Application to storage of platelets for transfusion. J Lab Clin Med 1978, 92:53-64.
-
(1978)
J Lab Clin Med
, vol.92
, pp. 53-64
-
-
Holme, S.1
Murphy, S.2
-
25
-
-
0019138434
-
Coulter counter and light transmission studies of platelets exposed to low temperature, ADP, EDTA, and storage at 22°C
-
Holme S., Murphy S. Coulter counter and light transmission studies of platelets exposed to low temperature, ADP, EDTA, and storage at 22°C. J Lab Clin Med 1980, 96:480-493.
-
(1980)
J Lab Clin Med
, vol.96
, pp. 480-493
-
-
Holme, S.1
Murphy, S.2
-
26
-
-
0019454932
-
Comparative measurements of platelet size by Coulter counter, microscopy of blood smears, and light transmission studies
-
Holme S., Simmonds M., Balek R., et al. Comparative measurements of platelet size by Coulter counter, microscopy of blood smears, and light transmission studies. J Lab Clin Med 1981, 97:610-622.
-
(1981)
J Lab Clin Med
, vol.97
, pp. 610-622
-
-
Holme, S.1
Simmonds, M.2
Balek, R.3
-
27
-
-
0020076255
-
Stored human platelets retain full aggregation potential in response to pairs of aggregating agents
-
DiMinno G., Silver M.J., Murphy S. Stored human platelets retain full aggregation potential in response to pairs of aggregating agents. Blood 1982, 59:563-568.
-
(1982)
Blood
, vol.59
, pp. 563-568
-
-
DiMinno, G.1
Silver, M.J.2
Murphy, S.3
-
28
-
-
0028108585
-
A multicenter evaluation of reproducibility of swirling in platelet concentrates
-
Bertolini F., Murphy S. A multicenter evaluation of reproducibility of swirling in platelet concentrates. Transfusion 1994, 34:796-801.
-
(1994)
Transfusion
, vol.34
, pp. 796-801
-
-
Bertolini, F.1
Murphy, S.2
-
29
-
-
0030068146
-
A multicenter inspection of the swirling phenomenon in platelet concentrates prepared in routine practice
-
Bertolini F., Murphy S. A multicenter inspection of the swirling phenomenon in platelet concentrates prepared in routine practice. Transfusion 1996, 36:128-132.
-
(1996)
Transfusion
, vol.36
, pp. 128-132
-
-
Bertolini, F.1
Murphy, S.2
-
30
-
-
0031938407
-
A multi-laboratory evaluation of in vitro platelet assays: The tests for extent of shape change and response to hypotonic shock
-
For the BEST Working Party of the ISBT
-
Holme S., Moroff G., Murphy S. A multi-laboratory evaluation of in vitro platelet assays: The tests for extent of shape change and response to hypotonic shock. Transfusion 1998, 38:31-40. For the BEST Working Party of the ISBT.
-
(1998)
Transfusion
, vol.38
, pp. 31-40
-
-
Holme, S.1
Moroff, G.2
Murphy, S.3
|