-
2
-
-
0001389022
-
Of flying frog and levitrons
-
10.1088/0143-0807/18/4/012
-
MV Berry AK Geim 1997 Of flying frog and levitrons Eur J Phys 18 307 313 10.1088/0143-0807/18/4/012
-
(1997)
Eur J Phys
, vol.18
, pp. 307-313
-
-
Berry, M.V.1
Geim, A.K.2
-
3
-
-
34547686578
-
Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation
-
DOI 10.1016/j.actbio.2007.03.002, PII S1742706107000384
-
CL Chu T Hu SL Wu, et al. 2007 Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation Acta Biomater 3 5 795 806 17466609 10.1016/j.actbio.2007.03.002 1:CAS:528:DC%2BD1cXhtVekt7bL (Pubitemid 47209514)
-
(2007)
Acta Biomaterialia
, vol.3
, Issue.5
, pp. 795-806
-
-
Chu, C.L.1
Hu, T.2
Wu, S.L.3
Dong, Y.S.4
Yin, L.H.5
Pu, Y.P.6
Lin, P.H.7
Chung, C.Y.8
Yeung, K.W.K.9
Chu, P.K.10
-
5
-
-
0034666723
-
In vitro analyses of diamond-like carbon coated stents: Reduction of metal ion release, platelet activation, and thrombogenicity
-
DOI 10.1016/S0049-3848(00)00295-4, PII S0049384800002954
-
K Gutensohn C Beythien J Bau, et al. 2000 In vitro analyses of diamond-like carbon coated stents: reduction of metal ion release, platelet activation, and thrombogenicity Thromb Res 99 6 577 585 10974344 10.1016/S0049-3848(00)00295-4 1:CAS:528:DC%2BD3cXmtF2iu7k%3D (Pubitemid 30642739)
-
(2000)
Thrombosis Research
, vol.99
, Issue.6
, pp. 577-585
-
-
Gutensohn, K.1
Beythien, C.2
Bau, J.3
Fenner, T.4
Grewe, P.5
Koester, R.6
Padmanaban, K.7
Kuehnl, P.8
-
7
-
-
0027200611
-
Orientation of erythrocytes in a strong static magnetic field
-
T Higashi A Yamagishi T Takeuchi N Kawaguchi, et al. 1993 Orientation of erythrocytes in a strong static magnetic field Blood 82 1328 1334 8353291 1:STN:280:DyaK3szlslCqsw%3D%3D (Pubitemid 23254010)
-
(1993)
Blood
, vol.82
, Issue.4
, pp. 1328-1334
-
-
Higashi, T.1
Yamagishi, A.2
Takeuchi, T.3
Kawaguchi, N.4
Sagawa, S.5
Onishi, S.6
Date, M.7
-
8
-
-
0027853067
-
Effects of a strong static magnetic field on blood platelets
-
T Higashi S Sagawa N Kawaguchi A Yamagishi 1993 Effects of a strong static magnetic field on blood platelets Platelets 4 341 342 21043604 10.3109/09537109309013238 1:STN:280:DC%2BC3cbkt1Wrsw%3D%3D (Pubitemid 24146988)
-
(1993)
Platelets
, vol.4
, Issue.6
, pp. 341-342
-
-
Higashi, T.1
Sagawa, S.2
Kawaguchi, N.3
Yamagishi, A.4
-
9
-
-
0031190905
-
Orientation of blood cells in static magnetic field
-
PII S0921452697002767
-
T Higashi N Ashida T Takeuchi 1997 Orientation of blood cells in static magnetic field Physica B 237/238 616 620 10.1016/S0921-4526(97)00276-7 (Pubitemid 127394371)
-
(1997)
Physica B: Condensed Matter
, vol.237-238
, pp. 616-620
-
-
Higashi, T.1
Ashida, N.2
Takeuchi, T.3
-
11
-
-
0038636424
-
2 film on NiTi surgical alloy for biocompatibility improvement
-
10.1016/S0040-6090(03)00146-9 1:CAS:528:DC%2BD3sXjtFWlu70%3D
-
2 film on NiTi surgical alloy for biocompatibility improvement Thin Solid Film 429 225 230 10.1016/S0040-6090(03)00146-9 1:CAS:528:DC%2BD3sXjtFWlu70%3D
-
(2003)
Thin Solid Film
, vol.429
, pp. 225-230
-
-
Liu, J.X.1
Yang, D.Z.2
Shi, F.3
-
13
-
-
10044220962
-
Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys
-
DOI 10.1016/j.biomaterials.2004.07.056, PII S0142961204006830
-
RW Poon KW Yeung XY Liu, et al. 2005 Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys Biomaterials 26 15 2265 2272 15585228 10.1016/j.biomaterials.2004.07.056 1:CAS:528:DC%2BD2cXhtVCiu7rJ (Pubitemid 39600679)
-
(2005)
Biomaterials
, vol.26
, Issue.15
, pp. 2265-2272
-
-
Poon, R.W.Y.1
Yeung, K.W.K.2
Liu, X.Y.3
Chu, P.K.4
Chung, C.Y.5
Lu, W.W.6
Cheung, K.M.C.7
Chan, D.8
-
14
-
-
34748904738
-
The catastrophe revisited: Blood compatibility in the 21st Century
-
DOI 10.1016/j.biomaterials.2007.07.035, PII S0142961207005832, Festschrift honouring Professor David F. Williams
-
BD Ratner 2007 The catastrophe revisited: blood compatibility in the 21st century Biomaterials 28 5144 5147 17689608 10.1016/j.biomaterials.2007.07.035 1:CAS:528:DC%2BD2sXhtFalsr3L (Pubitemid 47488493)
-
(2007)
Biomaterials
, vol.28
, Issue.34
, pp. 5144-5147
-
-
Ratner, B.D.1
-
15
-
-
41549097188
-
Critical overview of nitinol surface and their modifications for medical applications
-
18328796 10.1016/j.actbio.2008.01.013 1:CAS:528:DC%2BD1cXhtVarsr3M
-
S Shabalovskaya J Anderegg JV Humbeek 2008 Critical overview of nitinol surface and their modifications for medical applications Acta Biomater 4 447 467 18328796 10.1016/j.actbio.2008.01.013 1:CAS:528:DC%2BD1cXhtVarsr3M
-
(2008)
Acta Biomater
, vol.4
, pp. 447-467
-
-
Shabalovskaya, S.1
Anderegg, J.2
Humbeek, J.V.3
-
16
-
-
0001501479
-
Diamagnetic levitation: Flying frogs and floating magnets
-
10.1063/1.372654 1:CAS:528:DC%2BD3cXjtFGku78%3D
-
MD Simon AK Geim 2000 Diamagnetic levitation: flying frogs and floating magnets J Appl Phys 87 9 6200 6204 10.1063/1.372654 1:CAS:528: DC%2BD3cXjtFGku78%3D
-
(2000)
J Appl Phys
, vol.87
, Issue.9
, pp. 6200-6204
-
-
Simon, M.D.1
Geim, A.K.2
-
17
-
-
0034980299
-
Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy
-
DOI 10.1016/S0142-9612(00)00368-9, PII S0142961200003689
-
D Starosvetsky I Gotman 2001 Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical ally Biomaterials 22 1853 1859 11396890 10.1016/S0142-9612(00)00368-9 1:CAS:528:DC%2BD3MXksVynsr4%3D (Pubitemid 32564974)
-
(2001)
Biomaterials
, vol.22
, Issue.13
, pp. 1853-1859
-
-
Starosvetsky, D.1
Gotman, I.2
-
18
-
-
0036775460
-
Thrombogenicity of various endovascular stent types: An in vitro evaluation
-
G Tepe HP Wendl S Khorchidi J Schmehl J Wiskirchen B Pusich, et al. 2002 Thrombogenicity of various endovascular stent types: an in vitro evaluation J Vasc Interv 13 10 1029 1035 10.1016/S1051-0443(07)61868-5 (Pubitemid 35231860)
-
(2002)
Journal of Vascular and Interventional Radiology
, vol.13
, Issue.10
, pp. 1029-1035
-
-
Tepe, G.1
Wendel, H.P.2
Khorchidi, S.3
Schmehl, J.4
Wiskirchen, J.5
Pusich, B.6
Claussen, C.D.7
Duda, S.H.8
-
19
-
-
26844515262
-
Reduced thrombogenicity of nitinol stents - In vitro evaluation of different surface modifications and coatings
-
DOI 10.1016/j.biomaterials.2005.06.004, PII S0142961205005727
-
G Tepe J Schmehl HP Wendl S Sivio, et al. 2006 Reduced thrombogenicity of nitinol stents-in vitro evaluation of different surface modification and coatings Biomaterials 27 643 650 16095686 10.1016/j.biomaterials.2005.06.004 1:CAS:528:DC%2BD2MXhtFakur%2FL (Pubitemid 41464260)
-
(2006)
Biomaterials
, vol.27
, Issue.4
, pp. 643-650
-
-
Tepe, G.1
Schmehl, J.2
Wendel, H.P.3
Schaffner, S.4
Heller, S.5
Gianotti, M.6
Claussen, C.D.7
Duda, S.H.8
-
20
-
-
0036013823
-
Nitinol versus stainless steel stents: Acute thrombogenicity study in an ex vivo porcine model
-
DOI 10.1016/S0142-9612(02)00030-3, PII S0142961202000303
-
B Thierry Y Merhi L Bilodeau, et al. 2002 Nitinol versus stainless steel: acute thrombogenicity study in an ex vivo porcine model Biomaterials 23 2997 3005 12069342 10.1016/S0142-9612(02)00030-3 1:CAS:528:DC%2BD38XjsFKqu7o%3D (Pubitemid 34498321)
-
(2002)
Biomaterials
, vol.23
, Issue.14
, pp. 2997-3005
-
-
Thierry, B.1
Merhi, Y.2
Bilodeau, L.3
Trepanier, C.4
Tabrizian, M.5
-
21
-
-
0019349698
-
Oriented fibrin gels formed by polymerization in strong magnetic fields
-
DOI 10.1038/289091a0
-
J Torbet JM Freyssinet G Hudry-Clergeon 1981 Oriented fibrin gels formed by polymerization in strong magnetic fields Nature 289 91 93 7453812 10.1038/289091a0 1:CAS:528:DyaL3MXitVChsr8%3D (Pubitemid 11178464)
-
(1981)
Nature
, vol.289
, Issue.5793
, pp. 91-93
-
-
Torbet, J.1
Freyssinet, J.M.2
Hudry-Clergeon, G.3
-
22
-
-
18144440230
-
Structure and properties of titanium oxide layers prepared by metal plasma immersion ion implantation and deposition
-
DOI 10.1016/S0257-8972(03)00687-X
-
I Tsyganov MF Maitz E Wieser, et al. 2003 Structure and properties of titanium oxide layers prepared by metal plasma immersion ion implantation and deposition Surf Coat Technol 174-175 9-10 591 596 10.1016/S0257-8972(03)00687-X (Pubitemid 37054302)
-
(2003)
Surface and Coatings Technology
, vol.174-175
, pp. 591-596
-
-
Tsyganov, I.1
Maitz, M.F.2
Wieser, E.3
Prokert, F.4
Richter, E.5
Rogozin, A.6
-
23
-
-
0027108403
-
Diamagnetic orientation of blood cells in high magnetic field
-
10.1016/0921-4526(92)90162-L
-
A Yamagishi T Takeuchi T Higashi M Date 1992 Diamagnetic orientation of blood cells in high magnetic field Physica B 177 523 526 10.1016/0921-4526(92) 90162-L
-
(1992)
Physica B
, vol.177
, pp. 523-526
-
-
Yamagishi, A.1
Takeuchi, T.2
Higashi, T.3
Date, M.4
-
24
-
-
34447338046
-
Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: A comparative study with commonly used medical grade materials
-
DOI 10.1002/jbm.a.31154
-
KW Yeung RW Poon PK Chu, et al. 2007 Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials J Biomed Mater Res A 82 2 403 414 17295246 1:STN:280: DC%2BD2szmtlSntA%3D%3D (Pubitemid 47051672)
-
(2007)
Journal of Biomedical Materials Research - Part A
, vol.82
, Issue.2
, pp. 403-414
-
-
Yeung, K.W.K.1
Poon, R.W.Y.2
Chu, P.K.3
Chung, C.Y.4
Liu, X.Y.5
Lu, W.W.6
Chan, D.7
Chan, S.C.W.8
Luk, K.D.K.9
Cheung, K.M.C.10
|