메뉴 건너뛰기




Volumn 12, Issue 3, 2011, Pages 222-227

Contrast transoesophageal echocardiography remains superior to contrast-enhanced cardiac magnetic resonance imaging for the diagnosis of patent foramen ovale

Author keywords

Cardiovascular imaging; Ischaemic stroke; Patent foramen ovale

Indexed keywords

ADULT; AGED; ARTICLE; CARDIAC MAGNETIC RESONANCE; CONTRAST ENHANCEMENT; CRYPTOGENIC STROKE; DISEASE CLASSIFICATION; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PATENT FORAMEN OVALE; PREDICTIVE VALUE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; STROKE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VALSALVA MANEUVER;

EID: 79952613055     PISSN: 15252167     EISSN: 15322114     Source Type: Journal    
DOI: 10.1093/ejechocard/jeq177     Document Type: Article
Times cited : (32)

References (28)
  • 2
    • 0028832597 scopus 로고
    • Recurrent cerebrovascular events in patients with patent foramen ovale atrial septal aneurysm, or both and cryptogenic stroke or transient ischemic attack. French Study Group on Patent Foramen Ovale and Atrial Septal Aneurysm
    • Mas JL, Zuber M. Recurrent cerebrovascular events in patients with patent foramen ovale, atrial septal aneurysm, or both and cryptogenic stroke or transient ischemic attack. French Study Group on Patent Foramen Ovale and Atrial Septal Aneurysm. Am Heart J 1995;130:1083-8.
    • (1995) Am Heart J , vol.130 , pp. 1083-8
    • Mas, J.L.1    Zuber, M.2
  • 5
    • 0027371189 scopus 로고
    • Atrial septal aneurysm and patent foramen ovale as risk factors for cryptogenic stroke in patients less than 55 years of age: A study using transesophageal echocardiography
    • Cabanes L, Mas JL, Cohen A, Amarenco P, Cabanes PA, Oubary P et al. Atrial septal aneurysm and patent foramen ovale as risk factors for cryptogenic stroke in patients less than 55 years of age. A study using transesophageal echo-cardiography. Stroke 1993;24:1865-73. (Pubitemid 23352717)
    • (1993) Stroke , vol.24 , Issue.12 , pp. 1865-1873
    • Cabanes, L.1    Mas, J.L.2    Cohen, A.3    Amarenco, P.4    Cabanes, P.A.5    Oubary, P.6    Chedru, F.7    Guerin, F.8    Bousser, M.G.9    De Recondo, J.10
  • 6
    • 0026719903 scopus 로고
    • Risk of patent foramen ovale for thromboembolic events in all age groups
    • de Belder MA, Tourikis L, Leech G, Camm AJ. Risk of patent foramen ovale for thromboembolic events in all age groups. Am J Cardiol 1992;69:1316-20.
    • (1992) Am J Cardiol , vol.69 , pp. 1316-20
    • De Belder, M.A.1    Tourikis, L.2    Leech, G.3    Camm, A.J.4
  • 8
    • 0028851906 scopus 로고
    • Identification of patent foramen ovale per-mitting paradoxic embolism
    • Hausmann D, Mugge A, Daniel WG. Identification of patent foramen ovale per-mitting paradoxic embolism. J Am Coll Cardiol 1995;26:1030-8.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 1030-8
    • Hausmann, D.1    Mugge, A.2    Daniel, W.G.3
  • 9
    • 0028082344 scopus 로고
    • Characteristics of patent foramen ovale associated with cryptogenic stroke: A biplane transesophageal echocardiographic study
    • Homma S, Di Tullio MR, Sacco RL, Mihalatos D, Li Mandri G, Mohr JP. Charac-teristics of patent foramen ovale associated with cryptogenic stroke. A biplane transesophageal echocardiographic study. Stroke 1994;25:582-6. (Pubitemid 24067070)
    • (1994) Stroke , vol.25 , Issue.3 , pp. 582-586
    • Homma, S.1    Di Tullio, M.R.2    Sacco, R.L.3    Mihalatos, D.4    Mandri, G.L.5    Mohr, J.P.6
  • 10
    • 23844547935 scopus 로고    scopus 로고
    • Patent foramen ovale and stroke
    • Homma S, Sacco RL. Patent foramen ovale and stroke. Circulation 2005;112: 1063-72.
    • (2005) Circulation , vol.112 , pp. 1063-72
    • Homma, S.1    Sacco, R.L.2
  • 11
    • 0034669691 scopus 로고    scopus 로고
    • Transmitral Doppler: A new transthoracic contrast method for patent foramen ovale detection and quantification
    • Kerr AJ, Buck T, Chia K, Chow CM, Fox E, Levine RA et al. Transmitral Doppler: a new transthoracic contrast method for patent foramen ovale detection and quantification. J Am Coll Cardiol 2000;36:1959-66.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1959-66
    • Kerr, A.J.1    Buck, T.2    Chia, K.3    Chow, C.M.4    Fox, E.5    Levine, R.A.6
  • 13
    • 33847098787 scopus 로고    scopus 로고
    • Evaluating cardiac sources of embolic stroke with MRI
    • DOI 10.1111/j.1540-8175.2007.00393.x
    • Rustemli A, Bhatti TK, Wolff SD. Evaluating cardiac sources of embolic stroke with MRI. Echocardiography 2007;24:301-8; discussion 8. (Pubitemid 46280592)
    • (2007) Echocardiography , vol.24 , Issue.3 , pp. 301-308
    • Rustemli, A.1    Bhatti, T.K.2    Wolff, S.D.3
  • 14
    • 0027514354 scopus 로고
    • Classification of subtype of acute ischemic stroke: Definitions for use in a multicenter clinical trial
    • Adams HPJr, Bendixen BH, Kappelle LJ, Biller J, Love BB, Gordon DL et al. Classi-fication of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment. Stroke 1993; 24:35-41. (Pubitemid 23014379)
    • (1993) Stroke , vol.24 , Issue.1 , pp. 35-41
    • Adams Jr., H.P.1    Bendixen, B.H.2    Kappelle, L.J.3    Biller, J.4    Love, B.B.5    Gordon, D.L.6    Marsh III, E.E.7
  • 15
    • 0035857141 scopus 로고    scopus 로고
    • Recurrent cerebrovascular events associated with
    • patent foramen ovale, atrial septal aneur-ysm, or both
    • Mas JL, Arquizan C, Lamy C, Zuber M, Cabanes L, Derumeaux G et al. Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneur-ysm, or both. N Engl J Med 2001;345:1740-6.
    • (2001) N Engl J Med , vol.345 , pp. 1740-6
    • Mas, J.L.1    Arquizan, C.2    Lamy, C.3    Zuber, M.4    Cabanes, L.5    Derumeaux, G.6
  • 16
    • 33745699983 scopus 로고    scopus 로고
    • Cardiac mag-netic resonance imaging and transesophageal echocardiography in patients with transcatheter closure of
    • patent foramen ovale
    • Nusser T, Hoher M, Merkle N, Grebe OC, Spiess J, Kestler HA et al. Cardiac mag-netic resonance imaging and transesophageal echocardiography in patients with transcatheter closure of patent foramen ovale. J Am Coll Cardiol 2006;48:322-9.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 322-9
    • Nusser, T.1    Hoher, M.2    Merkle, N.3    Grebe, O.C.4    Spiess, J.5    Kestler, H.A.6
  • 17
    • 0037024261 scopus 로고    scopus 로고
    • Effect of medical treatment in stroke patients with patent foramen ovale: Patent foramen ovale in Cryptogenic Stroke Study
    • DOI 10.1161/01.CIR.0000017498.88393.44
    • Homma S, Sacco RL, Di Tullio MR, Sciacca RR, Mohr JP. Effect of medical treat-ment in stroke patients with patent foramen ovale: patent foramen ovale in Cryp-togenic Stroke Study. Circulation 2002;105:2625-31. (Pubitemid 34596039)
    • (2002) Circulation , vol.105 , Issue.22 , pp. 2625-2631
    • Homma, S.1    Sacco, R.L.2    Di Tullio, M.R.3    Sciacca, R.R.4    Mohr, J.P.5
  • 18
    • 65449153300 scopus 로고    scopus 로고
    • Association of right-to-left shunt with frontal white matter lesions in T2-weighted MR imaging of stroke patients
    • Liu JR, Plotz BM, Rohr A, Stingele R, Jansen O, Alfke K. Association of right-to-left shunt with frontal white matter lesions in T2-weighted MR imaging of stroke patients. Neuroradiology. 2009;51:299-304.
    • (2009) Neuroradiology. , vol.51 , pp. 299-304
    • Liu, J.R.1    Plotz, B.M.2    Rohr, A.3    Stingele, R.4    Jansen, O.5    Alfke, K.6
  • 19
    • 0034668078 scopus 로고    scopus 로고
    • The association between the diameter of a
    • patent foramen ovale and the risk of embolic cerebrovascular events
    • Schuchlenz HW, Weihs W, Horner S, Quehenberger F. The association between the diameter of a patent foramen ovale and the risk of embolic cerebrovascular events. Am J Med 2000;109:456-62.
    • (2000) Am J Med , vol.109 , pp. 456-62
    • Schuchlenz, H.W.1    Weihs, W.2    Horner, S.3    Quehenberger, F.4
  • 20
    • 0031971359 scopus 로고    scopus 로고
    • Patent foramen ovale size and embolic brain imaging findings among patients with ischemic stroke
    • Steiner MM, Di Tullio MR, Rundek T, Gan R, Chen X, Liguori C et al. Patent foramen ovale size and embolic brain imaging findings among patients with ischemic stroke. Stroke 1998;29:944-8.
    • (1998) Stroke , vol.29 , pp. 944-8
    • Steiner, M.M.1    Di Tullio, M.R.2    Rundek, T.3    Gan, R.4    Chen, X.5    Liguori, C.6
  • 22
    • 0034921864 scopus 로고    scopus 로고
    • Haemodynamic quantification of different provocation manoeuvres by simultaneous measurement of right and left atrial pressure: Implications for the echocardiographic detection of persistent foramen ovale
    • DOI 10.1053/euje.2000.0052
    • Pfleger S, Konstantin Haase K, Stark S, Latsch A, Simonis B, Scherhag A et al. Haemodynamic quantification of different provocation manoeuvres by simul-taneous measurement of right and left atrial pressure: implications for the echo-cardiographic detection of persistent foramen ovale. Eur J Echocardiogr 2001;2: 88-93. (Pubitemid 32677328)
    • (2001) European Journal of Echocardiography , vol.2 , Issue.2 , pp. 88-93
    • Pfleger, S.1    Konstantin Haase, K.2    Stark, S.3    Latsch, A.4    Simonis, B.5    Scherhag, A.6    Schumacher7    Voelker, W.8    Borggrefe, M.9
  • 23
    • 0029931512 scopus 로고    scopus 로고
    • Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings
    • DOI 10.1016/S0002-9149(96)00163-4
    • Schneider B, Zienkiewicz T,Jansen V, Hofmann T, Noltenius H, Meinertz T. Diag-nosis of patent foramen ovale by transesophageal echocardiography and corre-lation with autopsy findings. Am J Cardiol 1996;77:1202-9. (Pubitemid 26186962)
    • (1996) American Journal of Cardiology , vol.77 , Issue.14 , pp. 1202-1209
    • Schneider, B.1    Zienkiewicz, T.2    Jansen, V.3    Hofmann, T.4    Noltenius, H.5    Meinertz, T.6
  • 24
    • 15944387788 scopus 로고    scopus 로고
    • The proper conduct of valsalva maneuver in the detection of patent foramen ovale [2]
    • DOI 10.1016/j.jacc.2004.12.054
    • Cheng TO. The proper conduct of Valsalva maneuver in the detection of patent foramen ovale.JAm Coll Cardiol 2005;45:1145-6. (Pubitemid 40432452)
    • (2005) Journal of the American College of Cardiology , vol.45 , Issue.7 , pp. 1145-1146
    • Cheng, T.O.1
  • 25
    • 43049083996 scopus 로고    scopus 로고
    • Sensitivity for detection of patent foramen ovale increased with increasing number of contrast injections: A descriptive study with contrast transesophageal echocardiography
    • Johansson MC, Helgason H, Dellborg M, Eriksson P. Sensitivity for detection of patent foramen ovale increased with increasing number of contrast injections: a descriptive study with contrast transesophageal echocardiography. J Am Soc Echo-cardiogr 2008;21:419-24.
    • (2008) J Am Soc Echo-cardiogr , vol.21 , pp. 419-24
    • Johansson, M.C.1    Helgason, H.2    Dellborg, M.3    Eriksson, P.4
  • 27
    • 54049120091 scopus 로고    scopus 로고
    • Patent foramen ovale and migraine: A cross-sectional studyfrom the Northern Manhat-tan Study (NOMAS)
    • Rundek T, Elkind MS, Di Tullio MR, Carrera E, Jin Z, Sacco RL et al. Patent foramen ovale and migraine: a cross-sectional studyfrom the Northern Manhat-tan Study (NOMAS). Circulation 2008;118:1419-24.
    • (2008) Circulation , vol.118 , pp. 1419-24
    • Rundek, T.1    Elkind, M.S.2    Di Tullio, M.R.3    Carrera, E.4    Jin, Z.5    Sacco, R.L.6
  • 28
    • 67249104994 scopus 로고    scopus 로고
    • Percutaneous device closure of patent foramen ovale for secondary stroke prevention: A call for completion of randomized clinical trials: A science advisory from the American Heart Associ-ation/American Stroke Association and the American College of Cardiology Foundation
    • O'Gara PT, Messe SR, Tuzcu EM, Catha G, Ring JC. Percutaneous device closure of patent foramen ovale for secondary stroke prevention: a call for completion of randomized clinical trials: a science advisory from the American Heart Associ-ation/American Stroke Association and the American College of Cardiology Foundation. Circulation 2009;119:2743-7.
    • (2009) Circulation , vol.119 , pp. 2743-7
    • O'Gara, P.T.1    Messe, S.R.2    Tuzcu, E.M.3    Catha, G.4    Ring, J.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.