메뉴 건너뛰기




Volumn 66, Issue 2, 2011, Pages 163-169

Determination of some refractory elements and Pb by fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry with platform and wall vaporization

Author keywords

ETV ICP MS; Platform vaporization; PTFE; Slurry sampling; Wall vaporization

Indexed keywords

ETV-ICP-MS; PLATFORM VAPORIZATION; PTFE; SLURRY SAMPLING; WALL VAPORIZATION;

EID: 79952573076     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2011.01.006     Document Type: Article
Times cited : (7)

References (18)
  • 1
    • 41749122454 scopus 로고
    • Electrothermal atomization-the way toward absolute methods of atomic absorption spectrometry
    • B.V. L'vov Electrothermal atomization-the way toward absolute methods of atomic absorption spectrometry Spectrochim. Acta Part B 33 1978 153 193
    • (1978) Spectrochim. Acta Part B , vol.33 , pp. 153-193
    • L'Vov, B.V.1
  • 2
    • 0141638391 scopus 로고    scopus 로고
    • Exploratory analysis of L'vov platform surfaces for electrothermal atomic absorption spectrometry by using three-way chemometric tools
    • DOI 10.1016/j.aca.2003.08.015
    • E.R. Pereira-Filho, M.M. Sena, and M.A.Z. Arruda Exploratory analysis of L'vov platform surfaces for electrothermal atomic absorption spectrometry by using three-way chemometric tools Anal. Chim. Acta 495 2003 177 193 (Pubitemid 37211411)
    • (2003) Analytica Chimica Acta , vol.495 , Issue.1-2 , pp. 177-193
    • Pereira-Filho, E.R.1    Sena, M.M.2    Arruda, M.A.Z.3    Poppi, R.J.4
  • 3
    • 0032944303 scopus 로고    scopus 로고
    • Determination of gallium by graphite furnace atomic absorption spectrometry with combined use of a tungsten-coated L'vov platform tube and a chemical modification technique
    • DOI 10.1016/S0003-2670(99)00144-0, PII S0003267099001440
    • D. Ma, Y. Okamoto, T. Kumamaru, and E. Iwamoto Determination of gallium by graphite furnace atomic absorption spectrometry with combined use of a tungsten-coated L'vov platform tube and a chemical modification technique Anal. Chim. Acta 390 1999 201 206 (Pubitemid 29229847)
    • (1999) Analytica Chimica Acta , vol.390 , Issue.1-3 , pp. 201-206
    • Ma, D.1    Okamoto, Y.2    Kumamaru, T.3    Iwamoto, E.4
  • 4
    • 18844438932 scopus 로고    scopus 로고
    • Spectrometric and morphological characterization of condensed phase zirconium species produced during electrothermal heating on a graphite platform
    • DOI 10.1039/b416767h
    • M.A. Castro, A.J. Aller, A. McCabe, and W.E. Smith Spectrometric and morphological characterization of condensed phase zirconium species produced during electrothermal heating on a graphite platform J. Anal. At. Spectrom. 20 2005 385 394 (Pubitemid 40683110)
    • (2005) Journal of Analytical Atomic Spectrometry , vol.20 , Issue.5 , pp. 385-394
    • Castro, M.A.1    Aller, A.J.2    McCabe, A.3    Smith, W.E.4    Littlejohn, D.5
  • 5
    • 0010604409 scopus 로고
    • Progress in plasma-source mass spectrometry
    • A.R. Date, and A.L. Gray Progress in plasma-source mass spectrometry Spectrochim. Acta Part B 38 1983 29 37
    • (1983) Spectrochim. Acta Part B , vol.38 , pp. 29-37
    • Date, A.R.1    Gray, A.L.2
  • 6
    • 0000977453 scopus 로고
    • Relative merits of two methods is sample introduction in ICP-MS: Electrothermal vaporisation and direct sample insertion
    • G.E.M. hall, and J.C. Pelchat Relative merits of two methods is sample introduction in ICP-MS: electrothermal vaporisation and direct sample insertion J. Anal. At. Spectrom. 3 1988 791 797
    • (1988) J. Anal. At. Spectrom. , vol.3 , pp. 791-797
    • Hall, G.E.M.1    Pelchat, J.C.2
  • 7
    • 0030834954 scopus 로고    scopus 로고
    • Determination of copper, cadmium and lead in biological samples by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry
    • C.C. Chang, and S.J. Jiang Determination of copper, cadmium and lead in biological samples by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry J. Anal. At. Spectrom. 12 1997 75 80
    • (1997) J. Anal. At. Spectrom. , vol.12 , pp. 75-80
    • Chang, C.C.1    Jiang, S.J.2
  • 8
    • 2342642059 scopus 로고    scopus 로고
    • Platform-to-platform sample transfer, distribution, dilution, and dosing via electrothermal vaporization and electrostatic deposition
    • G. Hermann, A. Trenin, and R. Matz Platform-to-platform sample transfer, distribution, dilution, and dosing via electrothermal vaporization and electrostatic deposition Spectrochim. Acta Part B 59 2004 737 748
    • (2004) Spectrochim. Acta Part B , vol.59 , pp. 737-748
    • Hermann, G.1    Trenin, A.2    Matz, R.3
  • 9
    • 0028318277 scopus 로고
    • Graphite furnace hydride preconcentration and subsequent detection by inductively coupled plasma mass spectrometry
    • DOI 10.1016/0003-2670(94)85134-4
    • I. Marawi, J.S. Wang, and J.A. Caruso Graphite furnace hydride preconcentration and subsequent detection by ICP-MS Anal. Chim. Acta 291 1994 127 136 (Pubitemid 24171510)
    • (1994) Analytica Chimica Acta , vol.291 , Issue.1-2 , pp. 127-136
    • Marawi, I.1    Wang, J.2    Caruso, J.A.3
  • 10
    • 0002413702 scopus 로고
    • Utilization of metallic platforms in electrothermal vaporization inductively coupled mass spectrometry
    • I. Marawi, L.K. Olson, J.S. Wang, and J.A. Caruso Utilization of metallic platforms in electrothermal vaporization inductively coupled mass spectrometry J. Anal. At. Spectrom. 10 1995 7 14
    • (1995) J. Anal. At. Spectrom. , vol.10 , pp. 7-14
    • Marawi, I.1    Olson, L.K.2    Wang, J.S.3    Caruso, J.A.4
  • 11
    • 0342733510 scopus 로고    scopus 로고
    • Determination of trace metals in size fractionated particles from arctic air by ETV-ICP-MS
    • E. Hoffmann, J. Skole, and M. Kriews Determination of trace metals in size fractionated particles from arctic air by ETV-ICP-MS J. Anal. At. Spectrom. 14 1999 1685 1690
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 1685-1690
    • Hoffmann, E.1    Skole, J.2    Kriews, M.3
  • 12
    • 1842587847 scopus 로고    scopus 로고
    • Direct determination of trace impurities in niobium pentaoxide solid powder with slurry sampling fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry
    • S.Q. Li, B. Hu, and Z.C. Jiang Direct determination of trace impurities in niobium pentaoxide solid powder with slurry sampling fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry J. Anal. At. Spectrom. 19 2004 387 391
    • (2004) J. Anal. At. Spectrom. , vol.19 , pp. 387-391
    • Li, S.Q.1    Hu, B.2    Jiang, Z.C.3
  • 13
    • 0032938618 scopus 로고    scopus 로고
    • Determination of chromium in airborne particulate matter by high resolution and laser ablation inductively coupled plasma mass spectrometry
    • C.F. Wang, C.J. Chin, S.K. Luo, and L.C. Men Determination of chromium in airborne particulate matter by high resolution and laser ablation inductively coupled plasma mass spectrometry Anal. Chim. Acta 389 1999 257 266
    • (1999) Anal. Chim. Acta , vol.389 , pp. 257-266
    • Wang, C.F.1    Chin, C.J.2    Luo, S.K.3    Men, L.C.4
  • 14
    • 0030048102 scopus 로고    scopus 로고
    • Fluorination with polytetrafluoroethylene slurry in electrometry
    • B. Hu, Z.C. Jiang, and Y.C. Qin Fluorination with polytetrafluoroethylene slurry in electrometry Anal. Chim. Acta 319 1996 255 264
    • (1996) Anal. Chim. Acta , vol.319 , pp. 255-264
    • Hu, B.1    Jiang, Z.C.2    Qin, Y.C.3
  • 15
    • 0033709840 scopus 로고    scopus 로고
    • Direct analysis of silicon carbide by fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry using a slurry sampling technique
    • T.Y. Peng, X.H. Sheng, B. Hu, and Z.C. Jiang Direct analysis of silicon carbide by fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry using a slurry sampling technique Analyst 125 2000 2089 2093
    • (2000) Analyst , vol.125 , pp. 2089-2093
    • Peng, T.Y.1    Sheng, X.H.2    Hu, B.3    Jiang, Z.C.4
  • 16
    • 21144450983 scopus 로고    scopus 로고
    • Direct determination of trace refractory elements in human serum by ETV-ICP-MS with in-situ matrix removal
    • DOI 10.1007/s00216-004-2678-y
    • S.Q. Li, B. Hu, Z.C. Jiang, and R. Chen Direct determination of trace refractory elements in human serum by ETV-ICP-MS with in-situ matrix removal Anal. Bioanal. Chem. 379 2004 1076 1082 (Pubitemid 40877540)
    • (2004) Analytical and Bioanalytical Chemistry , vol.379 , Issue.7-8 , pp. 1076-1082
    • Li, S.1    Hu, B.2    Jiang, Z.3    Chen, R.4
  • 17
    • 0033553755 scopus 로고    scopus 로고
    • The application of chemical modification in electrothermal vaporization-inductively coupled plasma atomic emission spectrometry
    • B. Hu, Z.C. Jiang, T.Y. Peng, and Y.C. Qin The application of chemical modification in electrothermal vaporization-inductively coupled plasma atomic emission spectrometry Talanta 49 1999 357 365
    • (1999) Talanta , vol.49 , pp. 357-365
    • Hu, B.1    Jiang, Z.C.2    Peng, T.Y.3    Qin, Y.C.4
  • 18
    • 45549115450 scopus 로고
    • Interpreting some analytical characteristics of thermal dispersion methods used for sample introduction in atomic spectrometry
    • T. Kantor Interpreting some analytical characteristics of thermal dispersion methods used for sample introduction in atomic spectrometry Spectrochim. Acta Part B 43 1988 1299 1320
    • (1988) Spectrochim. Acta Part B , vol.43 , pp. 1299-1320
    • Kantor, T.1