메뉴 건너뛰기




Volumn 166, Issue 2, 2011, Pages 241-246

A microfluidic affinity sensor for the detection of cocaine

Author keywords

Affinity binding; Aptamer; Cocaine; Microfluidics; Sensor

Indexed keywords

AFFINITY BINDING; AFFINITY SENSOR; ANALYTES; APTAMER; APTAMERS; CARBOXYFLUORESCEIN; COCAINE; COCAINE DETECTION; DETECTION LIMITS; DEVICE OPERATIONS; FLUOROPHORE-QUENCHER PAIRS; FOUR-ORDER; FUNCTIONALIZED; LINEAR RESPONSE; MICRO-CHAMBERS; MICROBEADS; MICROFLUIDIC PLATFORMS; NANOMOLAR CONCENTRATION; ON CHIPS; RESONANCE ENERGY TRANSFER; SENSING SURFACE; SENSITIVE DETECTION; SENSOR RESPONSE; SPECIFIC DETECTION; TEMPERATURE DEPENDENT; THERMAL RELEASE; TO EFFECT;

EID: 79952533354     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2009.12.006     Document Type: Article
Times cited : (37)

References (22)
  • 2
    • 0038139573 scopus 로고    scopus 로고
    • A review of biological indicators of illicit drug use, practical considerations and clinical
    • K. Wolff, and M. Farrell A review of biological indicators of illicit drug use, practical considerations and clinical Addiction 94 1999 1279
    • (1999) Addiction , vol.94 , pp. 1279
    • Wolff, K.1    Farrell, M.2
  • 4
    • 26844518056 scopus 로고    scopus 로고
    • False positives and false negatives with a cocaine-specific field test and modification of test protocol to reduce false decision
    • DOI 10.1016/j.forsciint.2004.11.011, PII S0379073804007650
    • Y. Tsumura, T. Mitome, and S. Kimoto False positives and false negatives with a cocaine-specific field test and modification of test protocol to reduce false decision Forensic Science International 155 2-3 2005 158 164 (Pubitemid 41454952)
    • (2005) Forensic Science International , vol.155 , Issue.2-3 , pp. 158-164
    • Tsumura, Y.1    Mitome, T.2    Kimoto, S.3
  • 5
    • 0038077452 scopus 로고    scopus 로고
    • Further studies on spot tests and microcrystal tests for identification of cocaine
    • J. Swiatko, P.R.D. Forest, and M.S. Zedeck Further studies on spot tests and microcrystal tests for identification of cocaine Journal of Forensic Sciences 48 3 2003
    • (2003) Journal of Forensic Sciences , vol.48 , Issue.3
    • Swiatko, J.1    Forest, P.R.D.2    Zedeck, M.S.3
  • 7
    • 0025194307 scopus 로고
    • Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4 DNA polymerase
    • C. Tuerk, and L. Gold Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4 DNA polymerase Science 249 1990 505 510
    • (1990) Science , vol.249 , pp. 505-510
    • Tuerk, C.1    Gold, L.2
  • 9
    • 29344462970 scopus 로고    scopus 로고
    • Fast colorimetric sensing of adenosine and cocaine based on a general sensor design involving aptamers and nanoparticles
    • DOI 10.1002/anie.200502589
    • J. Liu, and Y. Lu Fast colorimetric sensing of adenosine and cocaine based on a general sensor design involving aptamers and nanoparticles Angewandte Chemie International Edition 45 1 2006 90 94 (Pubitemid 43003993)
    • (2006) Angewandte Chemie - International Edition , vol.45 , Issue.1 , pp. 90-94
    • Liu, J.1    Lu, Y.2
  • 10
    • 68849109203 scopus 로고    scopus 로고
    • Determination of cocaine in human plasma by selective solid-phase extraction using an aptamer-based sorbent
    • B. Madru, F. Chapuis-Hugon, and E. Peyrin Determination of cocaine in human plasma by selective solid-phase extraction using an aptamer-based sorbent Analytical Chemistry 81 16 2009 7081 7086
    • (2009) Analytical Chemistry , vol.81 , Issue.16 , pp. 7081-7086
    • Madru, B.1    Chapuis-Hugon, F.2    Peyrin, E.3
  • 11
    • 53849109617 scopus 로고    scopus 로고
    • A new aptameric biosensor for cocaine based on surface-enhanced raman scattering spectroscopy
    • J. Chen, J. Jiang, and X. Gao A new aptameric biosensor for cocaine based on surface-enhanced raman scattering spectroscopy Chemistry - A European Journal 14 27 2008 8374 8382
    • (2008) Chemistry - A European Journal , vol.14 , Issue.27 , pp. 8374-8382
    • Chen, J.1    Jiang, J.2    Gao, X.3
  • 12
    • 33644942097 scopus 로고    scopus 로고
    • An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological fluids
    • B.R. Baker, R.Y. Lai, and M.S. Wood An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological fluids Journal of the American Chemical Society 128 10 2006 3138 3139
    • (2006) Journal of the American Chemical Society , vol.128 , Issue.10 , pp. 3138-3139
    • Baker, B.R.1    Lai, R.Y.2    Wood, M.S.3
  • 13
    • 34548651768 scopus 로고    scopus 로고
    • Electrogenerated chemiluminescence aptamer-based biosensor for the determination of cocaine
    • DOI 10.1016/j.elecom.2007.07.038, PII S1388248107003141
    • Y. Li, H.L. Qi, and Y. Peng Electrogenerated chemiluminescence aptamer-based biosensor for the determination of cocaine Electrochemistry Communications 9 10 2007 2571 2575 (Pubitemid 47405284)
    • (2007) Electrochemistry Communications , vol.9 , Issue.10 , pp. 2571-2575
    • Li, Y.1    Qi, H.2    Peng, Y.3    Yang, J.4    Zhang, C.5
  • 14
    • 34250351427 scopus 로고    scopus 로고
    • A microfluidic device for presumptive testing of controlled substances
    • DOI 10.1111/j.1556-4029.2007.00478.x
    • S.C. Bell, and R.D. Hanes A microfluidic device for presumptive testing of controlled substances Journal of Forensic Sciences 52 4 2007 884 888 (Pubitemid 46918588)
    • (2007) Journal of Forensic Sciences , vol.52 , Issue.4 , pp. 884-888
    • Bell, S.C.1    Hanes, R.D.2
  • 16
    • 67749086547 scopus 로고    scopus 로고
    • Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor
    • J.S. Swensen, Y. Xiao, and B.S. Ferguson Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor Journal of the American Chemical Society 131 12 2009 4262 4266
    • (2009) Journal of the American Chemical Society , vol.131 , Issue.12 , pp. 4262-4266
    • Swensen, J.S.1    Xiao, Y.2    Ferguson, B.S.3
  • 18
    • 62649100432 scopus 로고    scopus 로고
    • An aptamer-based microfluidic device for thermally controlled affinity extraction
    • T. Nguyen, R. Pei, and M. Stojanovic An aptamer-based microfluidic device for thermally controlled affinity extraction Microfluidics and Nanofluidics 6 2009 479 487
    • (2009) Microfluidics and Nanofluidics , vol.6 , pp. 479-487
    • Nguyen, T.1    Pei, R.2    Stojanovic, M.3
  • 21
    • 0018160396 scopus 로고
    • Cocaine plasma concentration: Relation to physiological and subjective effects in humans
    • J.I. Javaid, M.W. Fischman, and C.R. Schuster Cocaine plasma concentration - relation to physiological and subjective effects in humans Science 202 4364 1978 227 228 (Pubitemid 9055122)
    • (1978) Science , vol.202 , Issue.4364 , pp. 227-228
    • Javaid, J.I.1    Fischman, M.W.2    Schuster, C.R.3
  • 22
    • 0036738031 scopus 로고    scopus 로고
    • Plasma deoxycholic acid concentration is elevated in postmenopausal women with newly diagnosed breast cancer
    • V. Costarelli, and T.A.B. Sanders Plasma deoxycholic acid concentration is elevated in postmenopausal women with newly diagnosed breast cancer European Journal of Clinical Nutrition 56 9 2002 925 927
    • (2002) European Journal of Clinical Nutrition , vol.56 , Issue.9 , pp. 925-927
    • Costarelli, V.1    Sanders, T.A.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.