-
1
-
-
0037312501
-
Inflammatory response to cardiopulmonary bypass
-
Levy J.H., Tanaka K.A. Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 2003, 75:715-720.
-
(2003)
Ann Thorac Surg
, vol.75
, pp. 715-720
-
-
Levy, J.H.1
Tanaka, K.A.2
-
2
-
-
1842735511
-
OPCAB versus early mortality and morbidity: an issue between clinical relevance and statistical significance
-
Sergeant P., Wouters P., Meyns B., Bert C., Van Hemelrijck J., Bogaerts C., Sergeant G., Slabbaert K. OPCAB versus early mortality and morbidity: an issue between clinical relevance and statistical significance. Eur J Cardiothorac Surg 2004, 25(5):779-785.
-
(2004)
Eur J Cardiothorac Surg
, vol.25
, Issue.5
, pp. 779-785
-
-
Sergeant, P.1
Wouters, P.2
Meyns, B.3
Bert, C.4
Van Hemelrijck, J.5
Bogaerts, C.6
Sergeant, G.7
Slabbaert, K.8
-
3
-
-
70350754575
-
On-pump versus off-pump coronary-artery bypass surgery
-
Veterans Affairs Randomized On/Off Bypass (ROOBY) Study Group
-
Shroyer A.L., Grover F.L., Hattler B., Collins J.F., McDonald G.O., Kozora E., Lucke J.C., Baltz J.H., Novitzky D. On-pump versus off-pump coronary-artery bypass surgery. N Engl J Med 2009, 361(19):1827-1837. Veterans Affairs Randomized On/Off Bypass (ROOBY) Study Group.
-
(2009)
N Engl J Med
, vol.361
, Issue.19
, pp. 1827-1837
-
-
Shroyer, A.L.1
Grover, F.L.2
Hattler, B.3
Collins, J.F.4
McDonald, G.O.5
Kozora, E.6
Lucke, J.C.7
Baltz, J.H.8
Novitzky, D.9
-
5
-
-
0036803163
-
Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation
-
Fromes Y., Gaillard D., Ponzio O., Chauffert M., Gerhardt M.F., Deleuze P., Bical O.M. Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation. Eur J Cardiothorac Surg 2002, 22(4):527-533.
-
(2002)
Eur J Cardiothorac Surg
, vol.22
, Issue.4
, pp. 527-533
-
-
Fromes, Y.1
Gaillard, D.2
Ponzio, O.3
Chauffert, M.4
Gerhardt, M.F.5
Deleuze, P.6
Bical, O.M.7
-
6
-
-
37349017602
-
Prospective randomized comparison of coronary bypass grafting with minimal extracorporeal circulation system (MECC) versus off-pump coronary surgery
-
Mazzei V., Nasso G., Salamone G., Castorino F., Tommasini A., Anselmi A. Prospective randomized comparison of coronary bypass grafting with minimal extracorporeal circulation system (MECC) versus off-pump coronary surgery. Circulation 2007, 116(16):1761-1767.
-
(2007)
Circulation
, vol.116
, Issue.16
, pp. 1761-1767
-
-
Mazzei, V.1
Nasso, G.2
Salamone, G.3
Castorino, F.4
Tommasini, A.5
Anselmi, A.6
-
7
-
-
0032801163
-
European system for cardiac operative risk evaluation (EuroSCORE)
-
Nashef S.A., Roques F., Michel P., Gauducheau E., Lemeshow S., Salamon R. European system for cardiac operative risk evaluation (EuroSCORE). Eur J Cardiothorac Surg 1999, 16(1):9-13.
-
(1999)
Eur J Cardiothorac Surg
, vol.16
, Issue.1
, pp. 9-13
-
-
Nashef, S.A.1
Roques, F.2
Michel, P.3
Gauducheau, E.4
Lemeshow, S.5
Salamon, R.6
-
8
-
-
84995360022
-
Management and outcome of patients with established coronary artery disease: the Euro Heart Survey on coronary revascularization
-
for the European Society of Cardiology
-
Lenzen M.J., Boersma E., Bertrand M.E., Maier W., Moris C., Piscione F., Sechtem U., Stahle E., Widimsky P., de Jaegere P., Scholte op Reimer W.J., Mercado N., Wijns W. Management and outcome of patients with established coronary artery disease: the Euro Heart Survey on coronary revascularization. Eur Heart J 2005, 26:1169-1179. for the European Society of Cardiology.
-
(2005)
Eur Heart J
, vol.26
, pp. 1169-1179
-
-
Lenzen, M.J.1
Boersma, E.2
Bertrand, M.E.3
Maier, W.4
Moris, C.5
Piscione, F.6
Sechtem, U.7
Stahle, E.8
Widimsky, P.9
de Jaegere, P.10
Scholte op Reimer, W.J.11
Mercado, N.12
Wijns, W.13
-
9
-
-
10044231710
-
Four years experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome
-
Wiesenack C., Liebold A., Philipp A., Ritzka M., Koppenberg J., Birnbaum D., Keyl C. Four years experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome. Artif Organ 2004, 28:1082-1088.
-
(2004)
Artif Organ
, vol.28
, pp. 1082-1088
-
-
Wiesenack, C.1
Liebold, A.2
Philipp, A.3
Ritzka, M.4
Koppenberg, J.5
Birnbaum, D.6
Keyl, C.7
-
10
-
-
4444333445
-
Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function
-
van Boven W.J., Gerritsen W.B., Waanders F.G., Haas F.J., Aarts L.P. Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function. Perfusion 2004, 19(4):239-246.
-
(2004)
Perfusion
, vol.19
, Issue.4
, pp. 239-246
-
-
van Boven, W.J.1
Gerritsen, W.B.2
Waanders, F.G.3
Haas, F.J.4
Aarts, L.P.5
-
11
-
-
64649098176
-
Myocardial revascularization with miniaturized extracorporeal circulation versus off pump: evaluation of systemic and myocardial inflammatory response in a prospective randomized study
-
Formica F., Broccolo F., Martino A., Sciucchetti J., Giordano V., Avalli L., Radaelli G., Ferro O., Corti F., Cocuzza C., Paolini G. Myocardial revascularization with miniaturized extracorporeal circulation versus off pump: evaluation of systemic and myocardial inflammatory response in a prospective randomized study. J Thorac Cardiovasc Surg 2009, 137(5):1206-1212.
-
(2009)
J Thorac Cardiovasc Surg
, vol.137
, Issue.5
, pp. 1206-1212
-
-
Formica, F.1
Broccolo, F.2
Martino, A.3
Sciucchetti, J.4
Giordano, V.5
Avalli, L.6
Radaelli, G.7
Ferro, O.8
Corti, F.9
Cocuzza, C.10
Paolini, G.11
-
12
-
-
60449086685
-
Minimal extracorporeal circulation: an alternative for on-pump and off-pump coronary revascularization
-
Puehler T., Haneya A., Philipp A., Wiebe K., Keyser A., Rupprecht L., Hirt S., Kobuch R., Diez C., Hilker M., Schmid C. Minimal extracorporeal circulation: an alternative for on-pump and off-pump coronary revascularization. Ann Thorac Surg 2009, 87(3):766-772.
-
(2009)
Ann Thorac Surg
, vol.87
, Issue.3
, pp. 766-772
-
-
Puehler, T.1
Haneya, A.2
Philipp, A.3
Wiebe, K.4
Keyser, A.5
Rupprecht, L.6
Hirt, S.7
Kobuch, R.8
Diez, C.9
Hilker, M.10
Schmid, C.11
-
13
-
-
71649103646
-
Is minimized extracorporeal circulation effective to reduce the need for red blood cell transfusion in coronary artery bypass grafting? Meta-analysis of randomized controlled trials
-
Benedetto U., Angeloni E., Refice S., Capuano F., Goracci M., Roscitano A., Sinatra R. Is minimized extracorporeal circulation effective to reduce the need for red blood cell transfusion in coronary artery bypass grafting? Meta-analysis of randomized controlled trials. J Thorac Cardiovasc Surg 2009, 138(6):1450-1453.
-
(2009)
J Thorac Cardiovasc Surg
, vol.138
, Issue.6
, pp. 1450-1453
-
-
Benedetto, U.1
Angeloni, E.2
Refice, S.3
Capuano, F.4
Goracci, M.5
Roscitano, A.6
Sinatra, R.7
-
14
-
-
34247179501
-
Attenuated renal and intestinal injury after use of a mini-cardiopulmonary bypass system
-
Huybregts R.A., Morariu A.M., Rakhorst G., Spiegelenberg S.R., Romijn H.W., de Vroege R., van Oeveren W. Attenuated renal and intestinal injury after use of a mini-cardiopulmonary bypass system. Ann Thorac Surg 2007, 83(5):1760-1766.
-
(2007)
Ann Thorac Surg
, vol.83
, Issue.5
, pp. 1760-1766
-
-
Huybregts, R.A.1
Morariu, A.M.2
Rakhorst, G.3
Spiegelenberg, S.R.4
Romijn, H.W.5
de Vroege, R.6
van Oeveren, W.7
-
15
-
-
34248184985
-
Clinical advantages of using mini-bypass systems in terms of blood product use, postoperative bleeding and air entrainment: an in vivo clinical perspective
-
Perthel M., El-Ayoubi L., Bendisch A., Laas J., Gerigk M. Clinical advantages of using mini-bypass systems in terms of blood product use, postoperative bleeding and air entrainment: an in vivo clinical perspective. Eur J Cardiothorac Surg 2007, 31(6):1070-1075.
-
(2007)
Eur J Cardiothorac Surg
, vol.31
, Issue.6
, pp. 1070-1075
-
-
Perthel, M.1
El-Ayoubi, L.2
Bendisch, A.3
Laas, J.4
Gerigk, M.5
-
16
-
-
44349149377
-
Blood transfusion is associated with increased resource utilisation, morbidity and mortality in cardiac surgery
-
Scott B.H., Seifert F.C., Grimson R. Blood transfusion is associated with increased resource utilisation, morbidity and mortality in cardiac surgery. Ann Card Anaesth 2008, 11(1):15-19.
-
(2008)
Ann Card Anaesth
, vol.11
, Issue.1
, pp. 15-19
-
-
Scott, B.H.1
Seifert, F.C.2
Grimson, R.3
-
17
-
-
33646845605
-
Transfusion in coronary artery bypass grafting is associated with reduced long-term survival
-
Koch C.G., Li L., Duncan A.I., Mihaljevic T., Loop F.D., Starr N.J., Blackstone E.H. Transfusion in coronary artery bypass grafting is associated with reduced long-term survival. Ann Thorac Surg 2006, 81(5):1650-1657.
-
(2006)
Ann Thorac Surg
, vol.81
, Issue.5
, pp. 1650-1657
-
-
Koch, C.G.1
Li, L.2
Duncan, A.I.3
Mihaljevic, T.4
Loop, F.D.5
Starr, N.J.6
Blackstone, E.H.7
-
18
-
-
33746209060
-
Circulating endothelial cells demonstrate an attenuation of endothelial damage by minimizing the extracorporeal circulation
-
Skrabal C.A., Choi Y.H., Kaminski A., Steiner M., Kundt G., Steinhoff G., Liebold A. Circulating endothelial cells demonstrate an attenuation of endothelial damage by minimizing the extracorporeal circulation. J Thorac Cardiovasc Surg 2006, 132(2):291-296.
-
(2006)
J Thorac Cardiovasc Surg
, vol.132
, Issue.2
, pp. 291-296
-
-
Skrabal, C.A.1
Choi, Y.H.2
Kaminski, A.3
Steiner, M.4
Kundt, G.5
Steinhoff, G.6
Liebold, A.7
-
19
-
-
35348860862
-
Minimal extracorporeal circulation is a promising technique for coronary artery bypass grafting
-
Immer F.F., Ackermann A., Gygax E., Stalder M., Englberger L., Eckstein F.S., Tevaearai H.T., Schmidli J., Carrel T.P. Minimal extracorporeal circulation is a promising technique for coronary artery bypass grafting. Ann Thorac Surg 2007, 84(5):1515-1520.
-
(2007)
Ann Thorac Surg
, vol.84
, Issue.5
, pp. 1515-1520
-
-
Immer, F.F.1
Ackermann, A.2
Gygax, E.3
Stalder, M.4
Englberger, L.5
Eckstein, F.S.6
Tevaearai, H.T.7
Schmidli, J.8
Carrel, T.P.9
-
20
-
-
36749014512
-
Effect of a miniaturized extracorporeal circulation (MECC System) on liver function
-
Prasser C., Abbady M., Keyl C., Liebold A., Tenderich M., Philipp A., Wiesenack C. Effect of a miniaturized extracorporeal circulation (MECC System) on liver function. Perfusion 2007, E22(4):245-250.
-
(2007)
Perfusion
, vol.E22
, Issue.4
, pp. 245-250
-
-
Prasser, C.1
Abbady, M.2
Keyl, C.3
Liebold, A.4
Tenderich, M.5
Philipp, A.6
Wiesenack, C.7
-
21
-
-
73949118513
-
Minimized extracorporeal circulation cannot prevent acute kidney injury but attenuates early renal dysfunction after coronary bypass grafting
-
Diez C., Haneya A., Brünger F., Philipp A., Hirt S., Ruppecht L., Kobuch R., Keyser A., Hilker M., Puehler T., Schmid C. Minimized extracorporeal circulation cannot prevent acute kidney injury but attenuates early renal dysfunction after coronary bypass grafting. ASAIO J 2009, 55(6):602-607.
-
(2009)
ASAIO J
, vol.55
, Issue.6
, pp. 602-607
-
-
Diez, C.1
Haneya, A.2
Brünger, F.3
Philipp, A.4
Hirt, S.5
Ruppecht, L.6
Kobuch, R.7
Keyser, A.8
Hilker, M.9
Puehler, T.10
Schmid, C.11
-
22
-
-
67650735170
-
Miniaturized cardiopulmonary bypass and acute kidney injury in coronary artery bypass graft surgery
-
Benedetto U., Luciani R., Goracci M., Capuano F., Refice S., Angeloni E., Roscitano A., Sinatra R. Miniaturized cardiopulmonary bypass and acute kidney injury in coronary artery bypass graft surgery. Ann Thorac Surg 2009, 88(2):529-535.
-
(2009)
Ann Thorac Surg
, vol.88
, Issue.2
, pp. 529-535
-
-
Benedetto, U.1
Luciani, R.2
Goracci, M.3
Capuano, F.4
Refice, S.5
Angeloni, E.6
Roscitano, A.7
Sinatra, R.8
-
23
-
-
70349973808
-
Minimised versus conventional cardiopulmonary bypass: outcome of high-risk patients
-
Haneya A., Philipp A., Schmid C., Diez C., Kobuch R., Hirt S., Zink W., Puehler T. Minimised versus conventional cardiopulmonary bypass: outcome of high-risk patients. Eur J Cardiothorac Surg 2009, 36(5):844-848.
-
(2009)
Eur J Cardiothorac Surg
, vol.36
, Issue.5
, pp. 844-848
-
-
Haneya, A.1
Philipp, A.2
Schmid, C.3
Diez, C.4
Kobuch, R.5
Hirt, S.6
Zink, W.7
Puehler, T.8
-
24
-
-
31044434626
-
Effect of closed minimized cardiopulmonary bypass on cerebral tissue oxygenation and microembolization
-
Liebold A., Khosravi A., Westphal B., Skrabal C., Choi Y.H., Stamm C., Kaminski A., Alms A., Birken T., Zurakowski D., Steinhoff G. Effect of closed minimized cardiopulmonary bypass on cerebral tissue oxygenation and microembolization. J Thorac Cardiovasc Surg 2006, 131(2):268-276.
-
(2006)
J Thorac Cardiovasc Surg
, vol.131
, Issue.2
, pp. 268-276
-
-
Liebold, A.1
Khosravi, A.2
Westphal, B.3
Skrabal, C.4
Choi, Y.H.5
Stamm, C.6
Kaminski, A.7
Alms, A.8
Birken, T.9
Zurakowski, D.10
Steinhoff, G.11
-
25
-
-
57649240835
-
Myocardial revascularization by left ventricular assisted beating heart is associated with reduced systemic inflammatory response
-
Stassano P., Di Tommaso L., Monaco M., Iesu S., Brando G., Buonpane S., Ambrosio G., Di Benedetto G., Pepino P. Myocardial revascularization by left ventricular assisted beating heart is associated with reduced systemic inflammatory response. Ann Thorac Surg 2009, 87(1):46-52.
-
(2009)
Ann Thorac Surg
, vol.87
, Issue.1
, pp. 46-52
-
-
Stassano, P.1
Di Tommaso, L.2
Monaco, M.3
Iesu, S.4
Brando, G.5
Buonpane, S.6
Ambrosio, G.7
Di Benedetto, G.8
Pepino, P.9
|