메뉴 건너뛰기




Volumn 133, Issue 6, 2011, Pages

Cooling characteristics of regenerative magnetic refrigeration with particle-packed bed

Author keywords

heat pump; magnetic refrigeration; magnetocaloric effect; regenerative cycle

Indexed keywords

A-THERMAL; ACTIVE MAGNETIC REGENERATORS; COOLING CHARACTERISTICS; COOLING PERFORMANCE; HEAT PUMPS; HEAT TRANSFER FLUIDS; MAGNETIC REFRIGERATORS; MAGNETOCALORIC; OPERATING CONDITION; REFRIGERATION CYCLES; REGENERATION PROCESS; REGENERATIVE CYCLE; ROOM TEMPERATURE; TEST SECTIONS;

EID: 79952530833     PISSN: 00221481     EISSN: 15288943     Source Type: Journal    
DOI: 10.1115/1.4003450     Document Type: Article
Times cited : (5)

References (16)
  • 1
    • 0038111928 scopus 로고    scopus 로고
    • Review on research of room temperature magnetic refrigeration
    • Yu, B. F., Gao, Q., Zhang, B., Meng, X. Z., and Chen, Z., 2003, "Review on Research of Room Temperature Magnetic Refrigeration", Int. J. Refrig., 26, pp. 622-636.
    • (2003) Int. J. Refrig. , vol.26 , pp. 622-636
    • Yu, B.F.1    Gao, Q.2    Zhang, B.3    Meng, X.Z.4    Chen, Z.5
  • 2
    • 33751162125 scopus 로고    scopus 로고
    • Experimental study on the performance of a room temperature magnetic refrigerator using permanent magnets
    • Yao, G. H., Gong, M. Q., and Wu, J. F., 2006, "Experimental Study on the Performance of a Room Temperature Magnetic Refrigerator Using Permanent Magnets", Int. J. Refrig., 29, pp. 1267-1273.
    • (2006) Int. J. Refrig. , vol.29 , pp. 1267-1273
    • Yao, G.H.1    Gong, M.Q.2    Wu, J.F.3
  • 3
    • 28844464477 scopus 로고    scopus 로고
    • Thermodynamics of magnetic refrigeration
    • DOI 10.1016/j.ijrefrig.2005.04.007, PII S0140700705001039
    • Kitanovski, A., and Egolf, P. W., 2006, "Thermodynamics of Magnetic Refrigeration", Int. J. Refrig., 29, pp. 3-21. (Pubitemid 41773383)
    • (2006) International Journal of Refrigeration , vol.29 , Issue.1 , pp. 3-21
    • Kitanovski, A.1    Egolf, P.W.2
  • 5
    • 18144414665 scopus 로고    scopus 로고
    • Analysis of room temperature magnetic regenerative refrigeration
    • DOI 10.1016/j.ijrefrig.2004.08.015, PII S0140700704002221
    • Shir, F., Mavriplis, C. L., Bennett, H., and Torre, E. D., 2005, "Analysis of Room Temperature Magnetic Regenerative Refrigeration", Int. J. Refrig., 28, pp. 616-627. (Pubitemid 40612650)
    • (2005) International Journal of Refrigeration , vol.28 , Issue.4 , pp. 616-627
    • Shir, F.1    Mavriplis, C.2    Bennett, L.H.3    Torre, E.D.4
  • 6
    • 33751224441 scopus 로고    scopus 로고
    • Static and rotating active magnetic regenerators with porous heat exchangers for magnetic cooling
    • DOI 10.1016/j.ijrefrig.2006.07.013, PII S0140700706001514, Magnetic Refrigeration at Room Temperature
    • Sarlah, A., Kitanovski, A., Poredos, A., Egolf, P. W., Sari, O., Gendre, F., and Besson, C., 2006, "Static and Rotating Active Magnetic Regenerators With Porous Heat Exchangers for Magnetic Cooling", Int. J. Refrig., 29, pp. 1332-1339. (Pubitemid 44781387)
    • (2006) International Journal of Refrigeration , vol.29 , Issue.8 , pp. 1332-1339
    • Sarlah, A.1    Kitanovski, A.2    Poredos, A.3    Egolf, P.W.4    Sari, O.5    Gendre, F.6    Besson, Ch.7
  • 7
    • 33751198497 scopus 로고    scopus 로고
    • Optimization of a magnetic refrigerator at room temperature for air cooling systems
    • Kawanami, T., Chiba, K., Sakurai, K., and Ikegawa, M., 2006, "Optimization of a Magnetic Refrigerator at Room Temperature for Air Cooling Systems", Int. J. Refrig., 29, pp. 1294-1301.
    • (2006) Int. J. Refrig. , vol.29 , pp. 1294-1301
    • Kawanami, T.1    Chiba, K.2    Sakurai, K.3    Ikegawa, M.4
  • 8
    • 40049085553 scopus 로고    scopus 로고
    • Two-dimensional mathematical model of a reciprocating room-temperature Active Magnetic Regenerator
    • DOI 10.1016/j.ijrefrig.2007.07.009, PII S0140700707001442
    • Petersen, T. F., Pryds, N., Smith, A., Hattel, J., Schmidt, H., and Knudsen, H. H., 2008, "Two-Dimensional Mathematical Model of a Reciprocating Room-Temperature Active Magnetic Regenerator", Int. J. Refrig., 31, pp. 432-443. (Pubitemid 351323902)
    • (2008) International Journal of Refrigeration , vol.31 , Issue.3 , pp. 432-443
    • Petersen, T.F.1    Pryds, N.2    Smith, A.3    Hattel, J.4    Schmidt, H.5    Hogaard Knudsen, H.-J.6
  • 9
    • 33751188078 scopus 로고    scopus 로고
    • Performance of a room-temperature rotary magnetic refrigerator
    • Okamura, T., Yamada, K., Hirano, N., and Nagaya, S., 2006, "Performance of a Room-Temperature Rotary Magnetic Refrigerator", Int. J. Refrig., 29, pp. 1327-1331.
    • (2006) Int. J. Refrig. , vol.29 , pp. 1327-1331
    • Okamura, T.1    Yamada, K.2    Hirano, N.3    Nagaya, S.4
  • 13
    • 0019635943 scopus 로고
    • Magnetic refrigeration in the temperature range from 10 K to room temperature: The ferromagnetic refrigerants
    • DOI 10.1016/0011-2275(81)90254-X
    • Hashimoto, T., Numasawa, T., Shino, M., and Okada, T., 1981, "Magnetic Refrigeration in the Temperature Range From 10 K to Room Temperature: The Ferromagnetic Refrigerants", Cryogenics, 21(11), pp. 647-653. (Pubitemid 12507316)
    • (1981) Cryogenics , vol.21 , Issue.11 , pp. 647-653
    • Hashimoto, T.1    Numasawa, T.2    Shino, M.3    Okada, T.4