Absolute blood velocity measured with a modified fundus camera

Author keywords

Absolute blood velocity; Flow; Perfusion; Radon transform

Indexed keywords

BASIC THEORY; BLOOD FLOW VELOCITY; BLOOD VELOCITY; CONFIDENCE INTERVAL; FLOW; FLOW DIRECTION; FLOW MODEL; FUNDUS CAMERA; GREEN LEDS; HIGH-SPEED CCD; IN-VITRO; LATERAL DISPLACEMENTS; PERFUSION; QUANTITATIVE ESTIMATION; RADON TRANSFORM;

EID: 79952499087     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3494565     Document Type: Article
Times cited : (32)

References (24)
  • 2
    • 66449137548 scopus 로고    scopus 로고
    • Doppler optical microangiography for volumetric imaging of vascular perfusion in vivo
    • R. K. Wang and L. An, "Doppler optical microangiography for volumetric imaging of vascular perfusion in vivo," Opt. Express 17, 8926-8940 (2009).
    • (2009) Opt. Express , vol.17 , pp. 8926-8940
    • Wang, R.K.1    An, L.2
  • 3
    • 80455158993 scopus 로고    scopus 로고
    • Visualizing ocular perfusion with optical microangiography
    • [DOI:]
    • R. Wang, L. An, and D. Wilson, "Visualizing ocular perfusion with optical microangiography," SPIE Newsroom (2010) [DOI:].
    • (2010) SPIE Newsroom
    • Wang, R.1    An, L.2    Wilson, D.3
  • 4
    • 50049105042 scopus 로고    scopus 로고
    • In vivo measurement of erythrocyte velocity and retinal blood flow using adaptive optics scanning laser ophthalmoscopy
    • Z. Zhong, B. L. Petrig, X. Qi, and S. A. Burns, "In vivo measurement of erythrocyte velocity and retinal blood flow using adaptive optics scanning laser ophthalmoscopy," Opt. Express 16, 12746-12756 (2008).
    • (2008) Opt. Express , vol.16 , pp. 12746-12756
    • Zhong, Z.1    Petrig, B.L.2    Qi, X.3    Burns, S.A.4
  • 5
    • 39049103737 scopus 로고    scopus 로고
    • Robust flow measurement with multi-exposure speckle imaging
    • A. B. Parthasarathy, W J. Tom, A. Gopal, X. Zhang, and A. K. Dunn, "Robust flow measurement with multi-exposure speckle imaging," Opt. Express 16, 1975-1989 (2008).
    • (2008) Opt. Express , vol.16 , pp. 1975-1989
    • Parthasarathy, A.B.1    Tom, W.J.2    Gopal, A.3    Zhang, X.4    Dunn, A.K.5
  • 6
    • 77953165954 scopus 로고    scopus 로고
    • Laser speckle contrast imaging in biomedical optics
    • D. A. Boas and A. K. Dunn, "Laser speckle contrast imaging in biomedical optics," J. Biomed. Opt. 15, 011109 (2010).
    • (2010) J. Biomed. Opt. , vol.15 , pp. 011109
    • Boas, D.A.1    Dunn, A.K.2
  • 8
    • 70349312290 scopus 로고    scopus 로고
    • Functional imaging using the retinal function imager: Direct imaging of blood velocity, achieving fluorescein angiography-like images without any contrast agent, qualitative oximetry, and functional metabolic signals
    • D. Izhaky, D. A. Nelson, Z. Burgansky-Eliash, and A. Grinvald, "Functional imaging using the retinal function imager: direct imaging of blood velocity, achieving fluorescein angiography-like images without any contrast agent, qualitative oximetry, and functional metabolic signals," Jpn. J. Ophthalmol. 53, 345-341 (2009).
    • (2009) Jpn. J. Ophthalmol. , vol.53 , pp. 345-341
    • Izhaky, D.1    Nelson, D.A.2    Burgansky-Eliash, Z.3    Grinvald, A.4
  • 9
    • 17844395707 scopus 로고    scopus 로고
    • Spatiotemporal image correlation spectroscopy (STICS) theory, verification, and application to protein velocity mapping in living CHO cells
    • B. Hebert, S. Costantino, and P. W. Wiseman, "Spatiotemporal image correlation spectroscopy (STICS) theory, verification, and application to protein velocity mapping in living CHO cells," Biophys. J. 88, 3601-3614 (2005).
    • (2005) Biophys. J. , vol.88 , pp. 3601-3614
    • Hebert, B.1    Costantino, S.2    Wiseman, P.W.3
  • 10
    • 62149135606 scopus 로고    scopus 로고
    • Spatiotemporal image correlation spectroscopy measurements of flow demonstrated in microfluidic channels
    • M. Rossow, W W Mantulin, and E. Gratton, "Spatiotemporal image correlation spectroscopy measurements of flow demonstrated in microfluidic channels," J. Biomed. Opt. 14, 024014 (2009).
    • (2009) J. Biomed. Opt. , vol.14 , pp. 024014
    • Rossow, M.1    Mantulin, W.W.2    Gratton, E.3
  • 11
    • 52649149805 scopus 로고    scopus 로고
    • Can laser speckle flowmetry be made a quantitative tool?
    • D. D. Duncan and S. J. Kirkpatrick, "Can laser speckle flowmetry be made a quantitative tool?" J. Opt. Soc. Am. A 25, 2088-2094 (2008).
    • (2008) J. Opt. Soc. Am. A , vol.25 , pp. 2088-2094
    • Duncan, D.D.1    Kirkpatrick, S.J.2
  • 13
    • 70449870159 scopus 로고    scopus 로고
    • An eye phantom for measurement of retinal oxygenation
    • P. Lemaillet and J. C. Ramella-Roman, "An eye phantom for measurement of retinal oxygenation," J. Biomed. Opt. 14(6), 064008 (2009).
    • (2009) J. Biomed. Opt. , vol.14 , Issue.6 , pp. 064008
    • Lemaillet, P.1    Ramella-Roman, J.C.2
  • 15
    • 0036382717 scopus 로고    scopus 로고
    • Fitts correlation tracker fidelity in presence of target translation, rotation, and size change
    • L. Stephan, J. E. Albus, and J. Marcovici, "Fitts correlation tracker fidelity in presence of target translation, rotation, and size change," Proc. SPIE 4714, 196-207 (2002).
    • (2002) Proc. SPIE , vol.4714 , pp. 196-207
    • Stephan, L.1    Albus, J.E.2    Marcovici, J.3
  • 16
    • 27544475435 scopus 로고    scopus 로고
    • Advanced correlation tracking of objects in cluttered imagery
    • S. Wong, "Advanced correlation tracking of objects in cluttered imagery," Proc. SPIE 5810, 158-169 (2005).
    • (2005) Proc. SPIE , vol.5810 , pp. 158-169
    • Wong, S.1
  • 17
    • 0031893842 scopus 로고    scopus 로고
    • Regional variation in capillary hemodynamics in the cat retina
    • P. S. Jensen and M. R. Gluckberg, "Regional variation in capillary hemodynamics in the cat retina," Invest. Ophthalmol. Visual Sci. 39, 407-415 (1998).
    • (1998) Invest. Ophthalmol. Visual Sci. , vol.39 , pp. 407-415
    • Jensen, P.S.1    Gluckberg, M.R.2
  • 18
    • 67249101565 scopus 로고    scopus 로고
    • Laser speckle contrast imaging for the quantitative assessment of flow
    • D. D. Duncan, S. J. Kirkpatrick, J. C. Gladish, and S. A. Hurst, "Laser speckle contrast imaging for the quantitative assessment of flow," Proc. SPIE 7176, 717603 (2009).
    • (2009) Proc. SPIE , vol.7176 , pp. 717603
    • Duncan, D.D.1    Kirkpatrick, S.J.2    Gladish, J.C.3    Hurst, S.A.4
  • 19
    • 0004236492 scopus 로고    scopus 로고
    • Matrix analysis
    • Third ed., Chap. 2, Johns Hopkins University Press, Baltimore
    • G. H. Golub and C. F Van Loan, "Matrix Analysis," in Matrix Computations, Third ed., Chap. 2, Johns Hopkins University Press, Baltimore (1996).
    • (1996) Matrix Computations
    • Golub, G.H.1    Van Loan, C.F.2
  • 20
    • 39849110971 scopus 로고    scopus 로고
    • In vivo whole-field blood velocity measurement techniques
    • P. Vennemann, R. Lindken, and J. Westerweel, "In vivo whole-field blood velocity measurement techniques," Exp. Fluids 42, 495-511 (2007).
    • (2007) Exp. Fluids , vol.42 , pp. 495-511
    • Vennemann, P.1    Lindken, R.2    Westerweel, J.3
  • 21
    • 0013916329 scopus 로고
    • On the significance of the reynolds number in blood flow
    • S. E. Charm and G. S. Kurland, "On the significance of the Reynolds number in blood flow," Biorheology 3(3), 163-164 (1966).
    • (1966) Biorheology , vol.3 , Issue.3 , pp. 163-164
    • Charm, S.E.1    Kurland, G.S.2
  • 22
    • 0014255829 scopus 로고
    • The influence of radial distribution and marginal plasma layer on the flow of red cell suspensions
    • S. E. Charm, G. S. Kurland, and S. L. Brown, "The influence of radial distribution and marginal plasma layer on the flow of red cell suspensions," Biorheology 5(1), 15-43 (1968).
    • (1968) Biorheology , vol.5 , Issue.1 , pp. 15-43
    • Charm, S.E.1    Kurland, G.S.2    Brown, S.L.3