메뉴 건너뛰기




Volumn 33, Issue 2, 2011, Pages 154-158

The responsiveness of different APTT reagents to mild factor VIII, IX and XI deficiencies

Author keywords

APTT; FIX; FVIII; FXI; Responsiveness

Indexed keywords

ACTIN FS; BLOOD CLOTTING FACTOR 11; BLOOD CLOTTING FACTOR 8; BLOOD CLOTTING FACTOR 9; DAPTTIN; REAGENT; STA PTTA; SYNTHASIL; UNCLASSIFIED DRUG;

EID: 79952459837     PISSN: 17515521     EISSN: 1751553X     Source Type: Journal    
DOI: 10.1111/j.1751-553X.2010.01261.x     Document Type: Article
Times cited : (53)

References (11)
  • 1
    • 79952481353 scopus 로고    scopus 로고
    • Intrinsic factor responsiveness of an APTT reagent is significantly influenced by the type of factor deficient plasma used
    • abstract 1901.
    • Bethel M., Adcock D.M. & Ramanathan R. (2005). Intrinsic factor responsiveness of an APTT reagent is significantly influenced by the type of factor deficient plasma used. Journal of Thrombosis and Haemostasis 3, Supplement 1 abstract 1901.
    • (2005) Journal of Thrombosis and Haemostasis , vol.3 , Issue.SUPPLEMENT. 1
    • Bethel, M.1    Adcock, D.M.2    Ramanathan, R.3
  • 4
    • 79952467734 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute (CLSI) One-stage prothrombin (PT) test and activated partial thromboplastin time (APTT) test. Approved guideline H47-A2.
    • Clinical and Laboratory Standards Institute (CLSI) (2008) One-stage prothrombin (PT) test and activated partial thromboplastin time (APTT) test. Approved guideline H47-A2. 28 (20).
    • (2008) , vol.28 , Issue.20
  • 6
    • 0031878077 scopus 로고    scopus 로고
    • Influence of phospholipids on the assessment of factor VIII activity
    • Mikaelsson M., Oswaldsson U. & Sandberg H. (1998) Influence of phospholipids on the assessment of factor VIII activity. Haemophilia 4, 646-650.
    • (1998) Haemophilia , vol.4 , pp. 646-650
    • Mikaelsson, M.1    Oswaldsson, U.2    Sandberg, H.3
  • 8
    • 63049084994 scopus 로고    scopus 로고
    • Influence of source of phospholipids for APTT-based factor IX assays and potential consequences for the diagnosis of mild haemophilia B
    • Pouplard C., Trossaert M., Le Querrec A., Delahousse B., Giraudeau B. & Gruel Y. (2009) Influence of source of phospholipids for APTT-based factor IX assays and potential consequences for the diagnosis of mild haemophilia B. Haemophilia 15, 365-368.
    • (2009) Haemophilia , vol.15 , pp. 365-368
    • Pouplard, C.1    Trossaert, M.2    Le Querrec, A.3    Delahousse, B.4    Giraudeau, B.5    Gruel, Y.6
  • 9
    • 0022483164 scopus 로고
    • The reliability of activated partial thromboplastin time methods and the relationship to lipid composition and ultrastructure
    • Stevenson K.J., Easton A.C., Curry A., Thomson J.M. & Poller L. (1986) The reliability of activated partial thromboplastin time methods and the relationship to lipid composition and ultrastructure. Thrombosis Haemostasis 55, 250-258.
    • (1986) Thrombosis Haemostasis , vol.55 , pp. 250-258
    • Stevenson, K.J.1    Easton, A.C.2    Curry, A.3    Thomson, J.M.4    Poller, L.5
  • 10
    • 0035091901 scopus 로고    scopus 로고
    • A normal APTT does not guarantee adequate coagulation factor levels
    • Teruya J., Oropeza M. & Ramsey G. (2001) A normal APTT does not guarantee adequate coagulation factor levels. Anaesthesiology 94, 542.
    • (2001) Anaesthesiology , vol.94 , pp. 542
    • Teruya, J.1    Oropeza, M.2    Ramsey, G.3
  • 11
    • 0022654149 scopus 로고
    • Sensitivity of three activated partial thromboplastin time reagents to coagulation factor deficiencies
    • Turi D.C. & Peerschke E.I. (1986) Sensitivity of three activated partial thromboplastin time reagents to coagulation factor deficiencies. American Journal of Clinical Pathology 85, 43-49.
    • (1986) American Journal of Clinical Pathology , vol.85 , pp. 43-49
    • Turi, D.C.1    Peerschke, E.I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.