메뉴 건너뛰기




Volumn , Issue , 2010, Pages 642-650

Use of a heat flow meter to determine active PCM content in an insulation

Author keywords

[No Author keywords available]

Indexed keywords

APPARENT THERMAL CONDUCTIVITY; BUILDING ENVELOPES; BUILDING SIMULATION; BUILDING STANDARDS; CELLULOSE INSULATION; CODE REQUIREMENTS; CONSENSUS STANDARDS; DIFFERENTIAL SCANNING CALORIMETERS; DYNAMIC EVALUATION; DYNAMIC HEAT; DYNAMIC OPERATIONS; DYNAMIC TESTING; DYNAMIC THERMAL CHARACTERISTICS; ENERGY ANALYSIS; ENERGY CODE; ENERGY PERFORMANCE; ENERGY SAVING; ENVIRONMENTAL CONDITIONS; EXPERIMENTAL METHODS; HEAT FLOW METERS; R VALUE; RESEARCH CENTER; SMALL SPECIMEN; STANDARDIZED TESTING; TEST SPECIMENS; TESTING METHOD; TESTING PROCEDURE; THERMAL ANALYSIS; THERMAL EFFICIENCY; THERMAL EVALUATIONS; THERMAL MASS; THERMAL STORAGE; TRANSIENT CHARACTERISTIC;

EID: 79952380203     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 2
    • 0031118122 scopus 로고    scopus 로고
    • Thermal behavior of mixtures of perlite and phase change material in a simulated climate
    • Petrie, T. W., K. W. Childs, P. W. Childs, J. E. Christian, and D. J. Shramo 1997. "Thermal Behavior of Mixtures of Perlite and Phase Change Material in a Simulated Climate, " in Insulation Materials: Testing and Applications: Third Volume, ASTM STP 1320, R.S. Graves and R.R. Zarr, eds. West Conshohocken, PA: American Society for Testing and Materials, pp. 180-194. (Pubitemid 127616053)
    • (1997) ASTM Special Technical Publication , vol.1320 , pp. 180-194
    • Petrie, T.W.1    Childs, K.W.2    Childs, P.W.3    Christian, J.E.4    Shramo, D.J.5
  • 6
    • 79952404075 scopus 로고    scopus 로고
    • Dynamiczna metoda pomiaru zawartosci materialu fazowo zmiennego w izolacji
    • Lodz University, Poland, June 2009, ISSN 1734-4891
    • Kossecka E. and J. Kosny 2009. "Dynamiczna Metoda Pomiaru Zawartosci Materialu Fazowo Zmiennego w Izolacji, " in Proceedings of the XII Conference Building Physics in Theory and Practice, Lodz University, Poland, June 2009, ISSN 1734-4891.
    • (2009) Proceedings of the XII Conference Building Physics in Theory and Practice
    • Kossecka, E.1    Kosny, J.2
  • 7
    • 45749135558 scopus 로고    scopus 로고
    • Hot box testing of building envelope assemblies: A simplified procedure for estimation of minimum time of the test
    • Kossecka E. and J. Kosny 2008. "Hot Box Testing of Building Envelope Assemblies: A Simplified Procedure for Estimation of Minimum Time of the Test, " Journal of Testing and Evaluation, 36(3): 242-249.
    • (2008) Journal of Testing and Evaluation , vol.36 , Issue.3 , pp. 242-249
    • Kossecka, E.1    Kosny, J.2
  • 8
    • 0031623514 scopus 로고    scopus 로고
    • Relationships between structure factors, response factors and Z-transfer function coefficients for multilayer walls
    • Kossecka E. 1998. "Relationships between Structure Factors, Response Factors and Z-transfer Function Coefficients for Multilayer Walls, " ASHRAE Transactions 104(1): 68-77.
    • (1998) ASHRAE Transactions , vol.104 , Issue.1 , pp. 68-77
    • Kossecka, E.1
  • 9
    • 0036532684 scopus 로고    scopus 로고
    • Influence of insulation configuration on heating and cooling loads in a continuously used building
    • DOI 10.1016/S0378-7788(01)00121-9, PII S0378778801001219
    • Kossecka E. and J. Kosny 2002. "Influence of Insulation Configuration on Heating and Cooling Loads in a Continuously Used Building, " Energy & Buildings 34(4): 321-331. (Pubitemid 34086552)
    • (2002) Energy and Buildings , vol.34 , Issue.4 , pp. 321-331
    • Kossecka, E.1    Kosny, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.