메뉴 건너뛰기




Volumn 12, Issue 3, 2011, Pages 458-560

Heartware third-generation implantable continuous flow pump as biventricular support: Mid-term follow-up

Author keywords

Biventricular assist device; Heart failure; Magnetic levitation

Indexed keywords

FRESH FROZEN PLASMA; HEMOGLOBIN; HEPARIN;

EID: 79952358591     PISSN: 15699293     EISSN: 15699285     Source Type: Journal    
DOI: 10.1510/icvts.2010.250654     Document Type: Article
Times cited : (36)

References (9)
  • 1
    • 33646243597 scopus 로고    scopus 로고
    • Third-generation blood pumps with mechanical non-contact magnetic bearings
    • Hoshi H, Shinshi T, Takatani S. Third-generation blood pumps with mechanical non-contact magnetic bearings. Artif Organs 2006;30:324-338.
    • (2006) Artif Organs , vol.30 , pp. 324-338
    • Hoshi, H.1    Shinshi, T.2    Takatani, S.3
  • 3
    • 77954959655 scopus 로고    scopus 로고
    • Design concepts and principle of operation of the HeartWare ventricular assist system
    • Larose JA, Tamez D, Ashenuga M, Reyes C. Design concepts and principle of operation of the HeartWare ventricular assist system. ASAIO J 2010; 56:285-289.
    • (2010) ASAIO J , vol.56 , pp. 285-289
    • Larose, J.A.1    Tamez, D.2    Ashenuga, M.3    Reyes, C.4
  • 4
    • 77953704021 scopus 로고    scopus 로고
    • Long-term biventricular support with the heartware implantable continuous flow pump
    • Hetzer R, Krabatsch T, Stepanenko A, Potapov EV. Long-term biventricular support with the heartware implantable continuous flow pump. J Heart Lung Transplant 2010;29:822-824.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 822-824
    • Hetzer, R.1    Krabatsch, T.2    Stepanenko, A.3    Potapov, E.V.4
  • 5
    • 77956879634 scopus 로고    scopus 로고
    • Successful use of the Heart Ware HVAD rotary blood pump for biventricular support
    • Strueber M, Meyer AL, Malehsa D, Haverich A. Successful use of the Heart Ware HVAD rotary blood pump for biventricular support. J Thorac Cardiovasc Surg 2010;140:936-937.
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 936-937
    • Strueber, M.1    Meyer, A.L.2    Malehsa, D.3    Haverich, A.4
  • 7
    • 44049094013 scopus 로고    scopus 로고
    • The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates
    • Matthews JC, Koelling TM, Pagani FD, Aaronson K. The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol 2008;51:2163-2172.
    • (2008) J Am Coll Cardiol , vol.51 , pp. 2163-2172
    • Matthews, J.C.1    Koelling, T.M.2    Pagani, F.D.3    Aaronson, K.4
  • 8
    • 57049100424 scopus 로고    scopus 로고
    • Tricuspid incompetence and geometry of the right ventricle as predictor of right ventricle function after implantation of a left ventricular assist device
    • Potapov EV, Stepanenko A, Dandel M, Kukucka M, Lehmkuhl HB, Weng Y, Hennig F, Krabatsch T, Hetzer R. Tricuspid incompetence and geometry of the right ventricle as predictor of right ventricle function after implantation of a left ventricular assist device. J Heart Lung Transplant 2008;27:1275-1281.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1275-1281
    • Potapov, E.V.1    Stepanenko, A.2    Dandel, M.3    Kukucka, M.4    Lehmkuhl, H.B.5    Weng, Y.6    Hennig, F.7    Krabatsch, T.8    Hetzer, R.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.