-
1
-
-
0026518731
-
Percutaneous release of the trigger finger: An office procedure
-
D.M. Eastwood, K.J. Gupta, and D.P. Johnson Percutaneous release of the trigger finger: an office procedure J Hand Surg 17A 1992 114 117
-
(1992)
J Hand Surg
, vol.17
, pp. 114-117
-
-
Eastwood, D.M.1
Gupta, K.J.2
Johnson, D.P.3
-
2
-
-
0028916555
-
Safety and efficacy of percutaneous trigger finger release
-
D.F. Pope, and S.W. Wolfe Safety and efficacy of percutaneous trigger finger release J Hand Surg 20A 1995 280 283
-
(1995)
J Hand Surg
, vol.20
, pp. 280-283
-
-
Pope, D.F.1
Wolfe, S.W.2
-
3
-
-
0029121711
-
Percutaneous A1 pulley release: A cadaveric study
-
G.I. Bain, J. Turnbull, M.N. Charles, J.H. Roth, and R.S. Richards Percutaneous A1 pulley release: a cadaveric study J Hand Surg 20A 1995 781 784
-
(1995)
J Hand Surg
, vol.20
, pp. 781-784
-
-
Bain, G.I.1
Turnbull, J.2
Charles, M.N.3
Roth, J.H.4
Richards, R.S.5
-
4
-
-
0032782184
-
Percutaneous trigger finger release: A comparison of a new push knife and a 19-gauge needle in a cadaveric model
-
DOI 10.1053/jhsu.1999.0860
-
M.J. Dunn, and G.M. Pess Percutaneous trigger finger release: a comparison of a new push knife and a 19-gauge needle in a cadaveric model J Hand Surg 24A 1999 860 865 (Pubitemid 29344812)
-
(1999)
Journal of Hand Surgery
, vol.24
, Issue.4
, pp. 860-865
-
-
Dunn, M.J.1
Pess, G.M.2
-
5
-
-
79952312541
-
Trigger finger: A prospective assessment of 76 digits treated by percutaneous surgery
-
E.S. Sato, W.M. Albertoni, V.M. Leite, J.B.G. Santos, and F. Faloppa Trigger finger: a prospective assessment of 76 digits treated by percutaneous surgery Rev Bras Ortop 39 2004 309 322
-
(2004)
Rev Bras Ortop
, vol.39
, pp. 309-322
-
-
Sato, E.S.1
Albertoni, W.M.2
Leite, V.M.3
Santos, J.B.G.4
Faloppa, F.5
-
6
-
-
0000370924
-
Surgical treatment of trigger-finger by a subcutaneous method
-
J. Lorthioir Surgical treatment of trigger-finger by a subcutaneous method J Bone Joint Surg 40A 1958 793 795
-
(1958)
J Bone Joint Surg
, vol.40
, pp. 793-795
-
-
Lorthioir, J.1
-
7
-
-
0026566051
-
Closed division of the flexor tendon sheath for trigger finger
-
S.R. Lyu Closed division of the flexor tendon sheath for trigger finger J Bone Joint Surg 74B 1992 418 420
-
(1992)
J Bone Joint Surg
, vol.74
, pp. 418-420
-
-
Lyu, S.R.1
-
8
-
-
0014468284
-
Experimental study of optimal location of flexor tendon pulleys
-
N.J. Barton Experimental study of optimal location of flexor tendon pulleys Plast Reconstr Surg 43 1969 125 129
-
(1969)
Plast Reconstr Surg
, vol.43
, pp. 125-129
-
-
Barton, N.J.1
-
9
-
-
0001322086
-
Flexor tendons-late reconstruction
-
L.H. Schneider, and J.M. Hunter Flexor tendons-late reconstruction D.P. Green, Operative hand surgery 1982 Churchill Livingstone New York 1375 1440
-
(1982)
Operative Hand Surgery
, pp. 1375-1440
-
-
Schneider, L.H.1
Hunter, J.M.2
-
10
-
-
0022283341
-
Digital flexor tendon sheath: An anatomic study
-
B. Strauch, and W. Moura Digital flexor tendon sheath: an anatomic study J Hand Surg 10A 1985 785 789 (Pubitemid 17173473)
-
(1985)
Journal of Hand Surgery
, vol.10
, pp. 785-789
-
-
Strauch, B.1
De Moura, W.2
-
11
-
-
0031157782
-
Percutaneous Release for Trigger Finger in Idiopathic and Hemodialysis Patients
-
M. Nagoshi, H. Hashizume, K. Nishida, H. Takagoshi, J. Pu, and H. Inoue Percutaneous release for trigger finger in idiopathic and hemodialysis patients Acta Med Okayama 51 1997 155 158 (Pubitemid 127459921)
-
(1997)
Acta Medica Okayama
, vol.51
, Issue.3
, pp. 155-158
-
-
Nagoshi, M.1
Hashizume, H.2
Nishida, K.3
Takagoshi, H.4
Pu, J.5
Inoue, H.6
-
12
-
-
34548540216
-
The results of percutaneous release of trigger digits by using full handle knife 15°: An anatomical hand surface landmark and clinical study
-
Y. Jongjirasiri The results of percutaneous release of trigger digits by using full handle knife 15 degrees: an anatomical hand surface landmark and clinical study J Med Assoc Thai 90 2007 1348 1355 (Pubitemid 47414508)
-
(2007)
Journal of the Medical Association of Thailand
, vol.90
, Issue.7
, pp. 1348-1355
-
-
Jongjirasiri, Y.1
-
13
-
-
0035884833
-
Trigger finger release with hand surface landmark ratios: An anatomic and clinical study
-
B.J. Wilhelmi, N. Snyder, J.E. Verbesey, P.A. Ganchi, and W.P.A. Lee Trigger finger release with hand surface landmark ratios: an anatomic and clinical study Plast Reconstr Surg 108 2001 908 915 (Pubitemid 32847711)
-
(2001)
Plastic and Reconstructive Surgery
, vol.108
, Issue.4
, pp. 908-915
-
-
Wilhelmi, B.J.1
Snyder, N.2
Verbesey, J.E.3
Ganchi, P.A.4
Lee, W.P.A.5
-
14
-
-
78149333241
-
Assessment of the distal extent of the A1 pulley release: A new technique
-
R. Hazani, N.J. Engineer, L.L. Zeineh, and B.J. Wilhelmi Assessment of the distal extent of the A1 pulley release: a new technique Eplasty 22 2008 423 427
-
(2008)
Eplasty
, vol.22
, pp. 423-427
-
-
Hazani, R.1
Engineer, N.J.2
Zeineh, L.L.3
Wilhelmi, B.J.4
-
16
-
-
78650145140
-
-
Wikipedia
-
Wikipedia Demographics of the United States http://en.wikipedia.org/wiki/ Demographics-of-the-United-States Accessed Aug 18, 2010
-
Demographics of the United States
-
-
-
17
-
-
79952312104
-
-
Brazilian Institute of Geography and Statistics
-
Brazilian Institute of Geography and Statistics Census2000 General population characteristics: sample results http://www.ibge.gov.br/home/ estatistica/populacao/censo2000/populacao/cor-raca-Censo2000.pdf Accessed Aug 18, 2010
-
Census2000: General Population Characteristics: Sample Results
-
-
-
18
-
-
84940509293
-
-
Wikipedia
-
Wikipedia Human height http://en.wikipedia.org/wiki/Human-height Accessed Aug 18, 2010
-
Human Height
-
-
|