메뉴 건너뛰기




Volumn 69, Issue 1, 2011, Pages 63-69

Comparison of analytical interferences on HbA1c measurement by two high pressure liquid chromatography analyzers;Comparaison des interférences analytiques sur le dosage de l'HbA1c par deux analyseurs de chromatographie liquide haute pression

Author keywords

Evaluation; HbA1c; High pressure liquid chromatography; Interference

Indexed keywords

BILIRUBIN; GLYCOSYLATED HEMOGLOBIN; HEMOGLOBIN; HEMOGLOBIN A1C PROTEIN, HUMAN; TRIACYLGLYCEROL;

EID: 79952287936     PISSN: 00033898     EISSN: 19506112     Source Type: Journal    
DOI: 10.1684/abc.2010.0511     Document Type: Article
Times cited : (9)

References (9)
  • 2
    • 0031914169 scopus 로고    scopus 로고
    • Evaluation of GHb assays in France by national quality control surveys
    • Gillery P., Dumont G., Vassault A. Evaluation of GHb assays in France by national quality control surveys. Diabetes Care 1998 21 265-70. (Pubitemid 28079436)
    • (1998) Diabetes Care , vol.21 , Issue.2 , pp. 265-270
    • Gillery, P.1    Dumont, G.2    Vassault, A.3
  • 3
    • 60349083849 scopus 로고    scopus 로고
    • Evaluation of Variant II analyzer equipped with the new 270-2101 NU kit (Bio-Rad) for HbA 1c assay
    • Lavalard E., Szymezak J., Leroy N., Gillery P. Evaluation of Variant II analyzer equipped with the new 270-2101 NU kit (Bio-Rad) for HbA 1c assay. Ann Biol Clin 2009 67 55-65.
    • (2009) Ann Biol Clin , vol.67 , pp. 55-65
    • Lavalard, E.1    Szymezak, J.2    Leroy, N.3    Gillery, P.4
  • 4
    • 79952291375 scopus 로고    scopus 로고
    • Evaluation of the G8 analyzer and PIANO software (Tosoh Bioscience) for glycated haemoglobin determination
    • Samaan S.L.A., Baron S., Fonfrède M. Evaluation of the G8 analyzer and PIANO software (Tosoh Bioscience) for glycated haemoglobin determination. Spectra Biol 2007 161 38-45.
    • (2007) Spectra Biol , vol.161 , pp. 38-45
    • Samaan, S.L.A.1    Baron, S.2    Fonfrède, M.3
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 1 307-10. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 51949088464 scopus 로고    scopus 로고
    • Interference of labile glycated hemoglobin on HbA(1c) assay by a high pressure liquid chromatography method
    • Szymezak J., Leroy N., Lavalard E., Gillery P. Interference of labile glycated hemoglobin on HbA(1c) assay by a high pressure liquid chromatography method. Ann Biol Clin 2008 66 459-63.
    • (2008) Ann Biol Clin , vol.66 , pp. 459-463
    • Szymezak, J.1    Leroy, N.2    Lavalard, E.3    Gillery, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.