메뉴 건너뛰기




Volumn 13, Issue 1, 2011, Pages 30-34

Better outcome after cardiopulmonary resuscitation using percutaneous emergency circulatory support in non-coronary patients compared to those with myocardial infarction

Author keywords

Cardiogenic shock; cardiomyopathy; emergency circulatory support; myocardial infarction; non ischemic heart failure

Indexed keywords

ACUTE HEART INFARCTION; ADULT; ARTICLE; ARTIFICIAL VENTILATION; ASSISTED CIRCULATION; CARDIOMYOPATHY; CARDIOPULMONARY HEMODYNAMICS; CARDIOVERSION; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY BYPASS SURGERY; DEFIBRILLATION; DEVICE REMOVAL; EXTRACORPOREAL OXYGENATION; FEMALE; HEART ARREST; HEART ASSIST DEVICE; HEART LEFT VENTRICLE ASSIST DEVICE; HEART MUSCLE REVASCULARIZATION; HEART TRANSPLANTATION; HUMAN; LUNG EMBOLISM; LUNG INSUFFICIENCY; MALE; MYOCARDITIS; OVERALL SURVIVAL; PERCUTANEOUS CORONARY INTERVENTION; PERCUTANEOUS EMERGENCY CIRCULATORY SUPPORT; PRIORITY JOURNAL; PUMPLESS EXTRACORPOREAL LUNG ASSIST; RESUSCITATION; RETROSPECTIVE STUDY; SURVIVAL RATE; SURVIVAL TIME; TUMOR LYSIS SYNDROME;

EID: 79952270106     PISSN: 17482941     EISSN: 1748295X     Source Type: Journal    
DOI: 10.3109/17482941.2010.542466     Document Type: Article
Times cited : (13)

References (21)
  • 2
    • 0029982824 scopus 로고    scopus 로고
    • Ptca with the use of cardiac assist devices: Risk stratifi cation short- and long-term results
    • Ferrari M.Scholz K.H.Figulla H.R. Ptca with the use of cardiac assist devices: Risk stratifi cation short- and long-term results ,Cathet. Cardiovasc Diagn. 1996, 38; 242-248
    • (1996) Cathet. Cardiovasc Diagn. , vol.38 , pp. 242-248
    • Ferrari, M.1    Scholz, K.H.2    Figulla, H.R.3
  • 3
    • 0023787284 scopus 로고
    • Hemodynamic eff ects of a counterpulsation device implanted on the ascending aorta in severe cardiogenic shock
    • N anas JN, Nanas SN, Charitos CE, Kontoyiannis D, Poyiadjis AD,Stamatopoulos G, et al. Hemodynamic eff ects of a counterpulsation device implanted on the ascending aorta in severe cardiogenic shock. ASAIO Trans. 1988;34:229 - 34.
    • (1988) Asaio Trans. , vol.34 , pp. 229-234
    • Nanas, J.N.1    Nanas, S.N.2    Charitos, C.E.3    Kontoyiannis, D.4    Poyiadjis, A.D.5    Stamatopoulos, G.6
  • 5
    • 0030018491 scopus 로고    scopus 로고
    • The heart-Hemopump interaction: A study of hemopump fl ow as a function of cardiac activity
    • M eyns B, Siess T, Laycock S, Reul H, Rau G, Flameng W. Th e heart-Hemopump interaction: A study of Hemopump fl ow as a function of cardiac activity. Artif Organs. 1996;20:641 - 9.
    • (1996) Artif. Organs. , vol.20 , pp. 641-649
    • Meyns, B.1    Siess, T.2    Laycock, S.3    Reul, H.4    Rau, G.5    Flameng, W.6
  • 6
    • 28844476448 scopus 로고    scopus 로고
    • Successful high-risk coronary angioplasty in a patient with cardiogenic shock under circulatory assist with a 16F axial flow pump
    • DOI 10.1002/ccd.20553
    • F errari M, Aboulhosn W, Figulla HR. Successful high-risk coronary angioplasty in a patient with cardiogenic shock under circulatory assist with a 16F axial fl ow pump. Catheter Cardiovasc Interv. 2005;66:557- 61. (Pubitemid 41779026)
    • (2005) Catheterization and Cardiovascular Interventions , vol.66 , Issue.4 , pp. 557-561
    • Ferrari, M.1    Aboulhosn, W.2    Figulla, H.R.3
  • 9
    • 49149095261 scopus 로고    scopus 로고
    • Cardiopulmonary resuscitation with assisted extracorporeal lifesupport versus conventional cardiopulmonary resuscitation in adults with in-hospital cardiac arrest: An observational study and propensity analysis
    • Chen Y.S.Lin J.W.Yu H.Y.Ko W.J.Jerng J.S.Chang W.T.et al, Cardiopulmonary resuscitation with assisted extracorporeal lifesupport versus conventional cardiopulmonary resuscitation in adults with in-hospital cardiac arrest: An observational study and propensity analysis; Lancet 2008;372:554 - 61.
    • (2008) Lancet , vol.372 , pp. 554-561
    • Chen, Y.S.1    Lin, J.W.2    Yu, H.Y.3    Ko, W.J.4    Jerng, J.S.5    Chang, W.T.6
  • 10
    • 0035183804 scopus 로고    scopus 로고
    • A mobile system for the treatment of accidental hypothermia with extracorporeal circulation
    • K jaergaard B, Tolboll P, Lyduch S, Trautner S. A mobile system for the treatment of accidental hypothermia with extracorporeal circulation. Perfusion 2001;16:453 - 9. (Pubitemid 33094560)
    • (2001) Perfusion , vol.16 , Issue.6 , pp. 453-459
    • Kjaergaard, B.1    Tolboll, P.2    Lyduch, S.3    Trautner, S.4
  • 11
    • 0030297367 scopus 로고    scopus 로고
    • Percutaneous venoarterial extracorporeal membrane oxygenation for emergency mechanical circulatory support
    • DOI 10.1016/S0300-9572(96)00989-6, PII S0300957296009896
    • Mair P, Hoermann C, Moertl M, Bonatti J, Falbesoner C. Percutaneous venoarterial extracorporeal membrane oxygenation for emergency mechanical circulatory support. Resuscitation 1996;33: 29 - 34. (Pubitemid 26400325)
    • (1996) Resuscitation , vol.33 , Issue.1 , pp. 29-34
    • Mair, P.1    Hoermann, C.2    Moertl, M.3    Bonatti, J.4    Falbesoner, C.5    Balogh, D.6
  • 12
    • 0027390083 scopus 로고
    • Circulatory support with shock due to acute myocardial infarction
    • Moritz A. Wolner E. Circulatory support with shock due to acute myocardial infarction; Ann. Thorac Surg. 1993. 55, 238-244 (Pubitemid 23026330)
    • (1993) Annals of Thoracic Surgery , vol.55 , Issue.1 , pp. 238-244
    • Moritz, A.1    Wolner, E.2
  • 15
    • 26844544776 scopus 로고    scopus 로고
    • LIFEBRIDGE: A portable, modular, rapidly available "Plug-and- Play" mechanical circulatory support system
    • DOI 10.1016/j.athoracsur.2005.03.040, PII S000349750500398X
    • M ehlhorn U, Brieske M, Fischer UM, Ferrari M, Brass P, Fischer JH, et al. LIFEBRIDGE: A portable, modular, rapidly available ' plug-and-play' mechanical circulatory support system. Ann Th orac Surg. 2005;80:1887- 92. (Pubitemid 41464319)
    • (2005) Annals of Thoracic Surgery , vol.80 , Issue.5 , pp. 1887-1892
    • Mehlhorn, U.1    Brieske, M.2    Fischer, U.M.3    Ferrari, M.4    Brass, P.5    Fischer, J.H.6    Zerkowski, H.-R.7
  • 16
    • 77955869798 scopus 로고    scopus 로고
    • Immediate percutaneous coronary intervention is associated with better survival aft er out-of-hospital cardiac arrest: Insights from the procat parisian region out of hospital cardiac arrest registry
    • D umas F, Cariou A, Manzo-Silberman S, Grimaldi D, Vivien B, Rosencher J, et al. Immediate percutaneous coronary intervention is associated with better survival aft er out-of-hospital cardiac arrest: Insights from the PROCAT (Parisian region out of hospital cardiac arrest) registry. Circ Cardiovasc Interv. 2010;3:200 - 7.
    • (2010) Circ. Cardiovasc Interv. , vol.3 , pp. 200-207
    • Dumas, F.1    Cariou, A.2    Manzo-Silberman, S.3    Grimaldi, D.4    Vivien, B.5    Rosencher, J.6
  • 17
    • 0037351947 scopus 로고    scopus 로고
    • Experience with percutaneous venoarterial cardiopulmonary bypass for emergency circulatory support
    • DOI 10.1097/01.CCM.0000053522.55711.E3
    • S chwarz B, Mair P, Margreiter J, Pomaroli A, Hoermann C, Bonatti J, et al. Experience with percutaneous venoarterial cardiopulmonary bypass for emergency circulatory support. Crit Care Med. 2003;31:758- 64. (Pubitemid 36379579)
    • (2003) Critical Care Medicine , vol.31 , Issue.3 , pp. 758-764
    • Schwarz, B.1    Mair, P.2    Margreiter, J.3    Pomaroli, A.4    Hoermann, C.5    Bonatti, J.6    Lindner, K.H.7
  • 18
    • 0028922758 scopus 로고
    • Cardiopulmonary bypass support of high risk coronary angioplasty patients: Registry results
    • V ogel RA. Cardiopulmonary bypass support of high risk coronary angioplasty patients: registry results. J Interv Cardiol. 1995; 8:193 - 7.
    • (1995) J. Interv. Cardiol. , vol.8 , pp. 193-197
    • Vogel, R.A.1
  • 21
    • 0029831312 scopus 로고    scopus 로고
    • Transport of hemodynamically unstable patients by a mobile mechanical circulatory support team
    • R eiss N, el-Banayosy A, Posival H, Knobl H, Minami K, Korfer R. Transport of hemodynamically unstable patients by a mobile mechanical circulatory support team. Artif Organs. 1996;20: 959 - 63. (Pubitemid 26273929)
    • (1996) Artificial Organs , vol.20 , Issue.8 , pp. 959-963
    • Reiss, N.1    El-Banayosy, A.2    Posival, H.3    Knobl, H.4    Minami, K.5    Korfer, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.