-
1
-
-
0032477679
-
Six-month angiographic outcome after successful repeat percutaneous intervention for in-stent restenosis
-
Bauters C, Banos JL, Van B 1. elle E, McFadden EP, Lablanche JM, Bertrand ME. Six-month angiographic outcome aft er successful repeat percutaneous intervention for in-stent restenosis. Circulation 1998; 97:318-21. (Pubitemid 28074331)
-
(1998)
Circulation
, vol.97
, Issue.4
, pp. 318-321
-
-
Bauters, C.1
Banos, J.-L.2
Van Belle, E.3
Mc Fadden, E.P.4
Lablanche, J.-M.5
Bertrand, M.E.6
-
2
-
-
0032374083
-
Directional coronary atherectomy for the treatment of Palmaz-Schatz in- stent restenosis
-
DOI 10.1016/S0002-9149(98)00639-0, PII S0002914998006390
-
Mahdi NA, Pathan AZ, Harrell L, 2. Leon MN, Lopez J, Butte A, et al. Directional coronary atherectomy for the treatment of Palmaz- Schatz in-stent restenosis. Am J Cardiol. 1998;82:1345-51. (Pubitemid 28565320)
-
(1998)
American Journal of Cardiology
, vol.82
, Issue.11
, pp. 1345-1351
-
-
Mahdi, N.A.1
Pathan, A.Z.2
Harrell, L.3
Leon, M.N.4
Lopez, J.5
Butte, A.6
Ferrell, M.7
Gold, H.K.8
Palacios, I.F.9
-
3
-
-
0034738067
-
Treatment of in-stent restenosis with excimer laser coronary angioplasty versus rotational atherectomy: Comparative mechanisms and results
-
M ehran R, Dangas G, Mintz GS, Waksman R, Abizaid A, Satler LF, et al. Treatment of in-stent restenosis with excimer laser coronary angioplasty versus rotational atherectomy: Comparative mechanisms and results. Circulation 2000;101:2484-9. (Pubitemid 30366252)
-
(2000)
Circulation
, vol.101
, Issue.21
, pp. 2484-2489
-
-
Mehran, R.1
Dangas, G.2
Mintz, G.S.3
Waksman, R.4
Abizaid, A.5
Satler, L.F.6
Pichard, A.D.7
Kent, K.M.8
Lansky, A.J.9
Stone, G.W.10
Leon, M.B.11
-
4
-
-
0037108116
-
Angiographic analysis of the angioplasty versus rotational atherectomy for the treatment of diff use in-stent restenosis trial ARTIST
-
D ietz U, Rupprecht H, de Belder M, Wijns W, Quarles van Ufford MA, Klues HG, et al. Angiographic analysis of the angioplasty versus rotational atherectomy for the treatment of diff use in-stent restenosis trial (ARTIST). Am J Cardiol. 2002;90:843-7.
-
(2002)
Am. J. Cardiol.
, vol.90
, pp. 843-847
-
-
Dietz, U.1
Rupprecht, H.2
De Belder, M.3
Wijns, W.4
Quarles Van Ufford, M.A.5
Klues, H.G.6
-
5
-
-
0023859104
-
Incidence of restenosis after successful coronary angioplasty: A time-related phenomenon. A quantitative angiographic study in 342 consecutive patients at 1, 2, 3, and 4 months
-
S erruys PW, Luijten HE, Beatt KJ, Geuskens R, de Feyter PJ, van den Brand M, et al. Incidence of restenosis aft er successful coronary angioplasty: a time-related phenomenon. A quantitative angiographic study in 342 consecutive patients at 1, 2, 3, and 4 months. Circulation 1988;77:361-71. (Pubitemid 18060045)
-
(1988)
Circulation
, vol.77
, Issue.2
, pp. 361-371
-
-
Serruys, P.W.1
Luijten, H.E.2
Beatt, K.J.3
Geuskens, R.4
De Feyter, P.J.5
Van Den Brand, M.6
Reiber, J.H.C.7
Ten Katen, H.J.8
Van Es, G.A.9
Hugenholtz, P.G.10
-
6
-
-
0023792836
-
Restenosis aft er successful percutaneous transluminal coronary angioplasty: Serial angiographic follow-up of 229 patients
-
N obuyoshi M, Kimura T, Nosaka H, Mioka S, Ueno K, Yokoi H, et al. Restenosis aft er successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients. J Am Coll Cardiol. 1988;12:616-23.
-
(1988)
J. Am. Coll. Cardiol.
, vol.12
, pp. 616-623
-
-
Nobuyoshi, M.1
Kimura, T.2
Nosaka, H.3
Mioka, S.4
Ueno, K.5
Yokoi, H.6
-
7
-
-
0031005933
-
Catheter-based radiotherapy to inhibit restenosis after coronary stenting
-
DOI 10.1056/NEJM199706123362402
-
T eirstein PS, Massullo V, Jani S, Popma JJ, Mintz GS, Russo RJ, et al. Catheter-based radiotherapy to inhibit restenosis aft er coronary stenting. N Engl J Med. 1997;336:1697-703. (Pubitemid 27251783)
-
(1997)
New England Journal of Medicine
, vol.336
, Issue.24
, pp. 1697-1703
-
-
Teirstein, P.S.1
Massullo, V.2
Jani, S.3
Popma, J.J.4
Mintz, G.S.5
Russo, R.J.6
Schatz, R.A.7
Guarneri, E.M.8
Steuterman, S.9
Morris, N.B.10
Leon, M.B.11
Tripuraneni, P.12
-
8
-
-
0034625080
-
Intracoronary γ-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis
-
W aksman R, White RL, Chan RC, Bass BG, Geirlach L, Mintz GS, et al. Intracoronary gamma-radiation therapy aft er angioplasty inhibits recurrence in patients with in-stent restenosis. Circulation 2000;101:2165-71. (Pubitemid 30253045)
-
(2000)
Circulation
, vol.101
, Issue.18
, pp. 2165-2171
-
-
Waksman, R.1
White, R.L.2
Chan, R.C.3
Bass, B.G.4
Geirlach, L.5
Mintz, G.S.6
Satler, L.F.7
Mehran, R.8
Serruys, P.W.9
Lansky, A.J.10
Fitzgerald, P.11
Bhargava, B.12
Kent, K.M.13
Pichard, A.D.14
Leon, M.B.15
-
9
-
-
0035945667
-
Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting
-
DOI 10.1056/NEJM200101253440402
-
L eon MB, Teirstein PS, Moses JW, Tripuraneni P, Lansky AJ, Jani S, et al. Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis aft er stenting. N Engl J Med. 2001; 344:250-6. (Pubitemid 32108529)
-
(2001)
New England Journal of Medicine
, vol.344
, Issue.4
, pp. 250-256
-
-
Leon, M.B.1
Teirstein, P.S.2
Moses, J.W.3
Tripuraneni, P.4
Lansky, A.J.5
Jani, S.6
Wong, S.C.7
Fish, D.8
Ellis, S.9
Holmes, D.R.10
Kerieakes, D.11
Kuntz, R.E.12
-
10
-
-
17544400054
-
Intracoronary β-radiation therapy inhibits recurrence of in-stent restenosis
-
W aksman R, Bhargava B, White L, Chan RC, Mehran R, Lansky AJ, et al. Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis. Circulation 2000;101:1895 - 8. (Pubitemid 30225268)
-
(2000)
Circulation
, vol.101
, Issue.16
, pp. 1895-1898
-
-
Waksman, R.1
Bhargava, B.2
White, L.3
Chan, R.C.4
Mehran, R.5
Lansky, A.J.6
Mintz, G.S.7
Satler, L.F.8
Pichard, A.D.9
Leon, M.B.10
Kent, K.K.11
-
11
-
-
0037183375
-
90Y β-radiation versus placebo control for treatment of in-stent restenosis
-
DOI 10.1161/01.CIR.0000027814.96651.72
-
P opma JJ, Suntharalingam M, Lansky AJ, Heuser RR, Speiser B, Teirstein PS, et al., Stents And Radiation Th erapy (START) Investigators. Randomized trial of 90Sr/90Y beta-radiation versus placebo control for treatment of in-stent restenosis. Circulation 2002;106:1090-6. (Pubitemid 34970849)
-
(2002)
Circulation
, vol.106
, Issue.9
, pp. 1090-1096
-
-
Popma, J.J.1
Suntharalingam, M.2
Lansky, A.J.3
Heuser, R.R.4
Speiser, B.5
Teirstein, P.S.6
Massullo, V.7
Bass, T.8
Henderson, R.9
Silber, S.10
Von Rottkay, P.11
Bonan, R.12
Ho, K.K.L.13
Osattin, A.14
Kuntz, R.E.15
-
12
-
-
0034142223
-
Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial
-
T eirstein PS, Massullo V, Jani S, Popma JJ, Russo RJ, Schatz RA, et al. Th ree-year clinical and angiographic follow-up aft er intracoronary radiation: Results of a randomized clinical trial. Circulation 2000;101:360-5. (Pubitemid 30067390)
-
(2000)
Circulation
, vol.101
, Issue.4
, pp. 360-365
-
-
Teirstein, P.S.1
Massullo, V.2
Jani, S.3
Popma, J.J.4
Russo, R.J.5
Schatz, R.A.6
Guarneri, E.M.7
Steuterman, S.8
Sirkin, K.9
Cloutier, D.A.10
Leon, M.B.11
Tripuraneni, P.12
-
13
-
-
0037062647
-
Five-year clinical follow-up after intracoronary radiation: Results of a randomized clinical trial
-
DOI 10.1161/01.CIR.0000018126.87045.E0
-
G rise MA, Massullo V, Jani S, Popma JJ, Russo RJ, Schatz RA, et al. Five-year clinical follow-up aft er intracoronary radiation: Results of a randomized clinical trial. Circulation 2002;105:2737-40. (Pubitemid 34615144)
-
(2002)
Circulation
, vol.105
, Issue.23
, pp. 2737-2740
-
-
Grise, M.A.1
Massullo, V.2
Jani, S.3
Popma, J.J.4
Russo, R.J.5
Schatz, R.A.6
Guarneri, E.M.7
Steuterman, S.8
Cloutier, D.A.9
Leon, M.B.10
Tripuraneni, P.11
Teirstein, P.S.12
-
14
-
-
0035880739
-
Two-year follow-up after beta and gamma intracoronary radiation therapy for patients with diffuse in-stent restenosis
-
DOI 10.1016/S0002-9149(01)01694-0, PII S0002914901016940
-
W aksman R, Ajani AE, White RL, Pinnow E, Mehran R, Bui AB, et al. Two-year follow-up aft er beta and gamma intracoronary radiation therapy for patients with diff use in-stent restenosis. Am J Cardiol. 2001;88:425-8. (Pubitemid 32823309)
-
(2001)
American Journal of Cardiology
, vol.88
, Issue.4
, pp. 425-428
-
-
Waksman, R.1
Ajani, A.E.2
White, R.L.3
Pinnow, E.4
Mehran, R.5
Bui, A.B.6
Deible, R.7
Gruberg, L.8
Mintz, G.S.9
Satler, L.F.10
Pichard, A.D.11
Kent, K.M.12
Lindsay, J.13
-
15
-
-
9144225347
-
Five-year follow-up aft er intracoronary gamma radiation therapy for in-stent restenosis
-
DOI 10.1161/01.CIR.0000109488.62415.01
-
W aksman R, Ajani AE, White RL, Chan R, Bass B, Pichard AD, et al. Five-year follow-up aft er intracoronary gamma radiation therapy for in-stent restenosis. Circulation 2004;109:340-4. Epub 19 Jan 2004. (Pubitemid 38133901)
-
(2004)
Circulation
, vol.109
, Issue.3
, pp. 340-344
-
-
Waksman, R.1
Ajani, A.E.2
White, R.L.3
Chan, R.4
Bass, B.5
Pichard, A.D.6
Satler, L.F.7
Kent, K.M.8
Torguson, R.9
Deible, R.10
Pinnow, E.11
Lindsay, J.12
-
16
-
-
20144387318
-
Two-year clinical follow-up of 90Sr/90Y beta-radiation versus placebo control for the treatment of in-stent restenosis
-
for the START investigators
-
S ilber S, Popma JJ, Sunthalaringam M, Lansky AJ, Heuser RR, Speiser B, et al., for the START investigators. Two-year clinical follow-up of 90Sr/90Y beta-radiation versus placebo control for the treatment of in-stent restenosis. Am Heart J. 2005;149: 689-94.
-
(2005)
Am. Heart J.
, vol.149
, pp. 689-694
-
-
Silber, S.1
Popma, J.J.2
Sunthalaringam, M.3
Lansky, A.J.4
Heuser, R.R.5
Speiser, B.6
-
17
-
-
12144289731
-
Evolution of angiographic restenosis rate and late lumen loss after intracoronary beta radiation for in-stent restenotic lesions
-
DOI 10.1016/j.amjcard.2003.12.020, PII S000291490301748X
-
S chiele TM, Pollinger B, Kantlehner R, Rieber J, Konig A, Seelig V, et al. Evolution of angiographic restenosis rate and late lumen loss aft er intracoronary beta radiation for in-stent restenotic lesions. Am J Cardiol. 2004;93:836-42. (Pubitemid 38429593)
-
(2004)
American Journal of Cardiology
, vol.93
, Issue.7
, pp. 836-842
-
-
Schiele, T.M.1
Pollinger, B.2
Kantlehner, R.3
Rieber, J.4
Konig, A.5
Seelig, V.6
Krotz, F.7
Sohn, H.-Y.8
Siebert, U.9
Duhmke, E.10
Theisen, K.11
Klauss, V.12
-
18
-
-
0028799838
-
Intracoronary low-dose beta-irradiation inhibits neointima formation aft er coronary artery balloon injury in the swine restenosis model
-
W aksman R, Robinson KA, Crocker IR, Wang C, Gravanis MB, Cipolla GD, et al. Intracoronary low-dose beta-irradiation inhibits neointima formation aft er coronary artery balloon injury in the swine restenosis model. Circulation 1995;92:3025-31.
-
(1995)
Circulation
, vol.92
, pp. 3025-3031
-
-
Waksman, R.1
Robinson, K.A.2
Crocker, I.R.3
Wang, C.4
Gravanis, M.B.5
Cipolla, G.D.6
-
19
-
-
0033527438
-
32P radioactive stents in an atherosclerotic porcine coronary model
-
C arter AJ, Scott D, Bailey L, Hoopes T, Jones R, Virmani R. Doseresponse eff ects of 32 P radioactive stents in an atherosclerotic porcine coronary model. Circulation 1999;100:1548-54. (Pubitemid 29461468)
-
(1999)
Circulation
, vol.100
, Issue.14
, pp. 1548-1554
-
-
Carter, A.J.1
Scott, D.2
Bailey, L.3
Hoopes, T.4
Jones, R.5
Virmani, R.6
-
20
-
-
0035856530
-
Intracoronary β-radiation exacerbates long-term neointima formation in balloon-injured pig coronary arteries
-
C oussement PK, de Leon H, Ueno T, Salame MY, King SB 3rd, Chronos NA, et al. Intracoronary beta-radiation exacerbates long-term neointima formation in balloon-injured pig coronary arteries. Circulation 2001;104:2459-64. (Pubitemid 33108381)
-
(2001)
Circulation
, vol.104
, Issue.20
, pp. 2459-2464
-
-
Coussement, P.K.1
De Leon, H.2
Ueno, T.3
Salame, M.Y.4
King III, S.B.5
Chronos, N.A.F.6
Robinson, K.A.7
-
21
-
-
0028339070
-
Intracoronary irradiation markedly reduces restenosis after balloon angioplasty in a porcine model
-
W iedermann JG, Marboe C, Amols H, Schwartz A, Weinberger J. Intracoronary irradiation markedly reduces restenosis aft er balloon angioplasty in a porcine model. J Am Coll Cardiol. 1994;23: 1491-8. (Pubitemid 24158023)
-
(1994)
Journal of the American College of Cardiology
, vol.23
, Issue.6
, pp. 1491-1498
-
-
Wiedermann, J.G.1
Marboe, C.2
Amols, H.3
Schwartz, A.4
Weinberger, J.5
-
22
-
-
46849111727
-
Two-year clinical outcomes after paclitaxel-eluting stent or brachytherapy treatment for bare metal stent restenosis: The TAXUS V ISR trial
-
DOI 10.1093/eurheartj/ehn231
-
E llis SG, O' S haughnessy CD, Martin SL, Kent K, McGarry T, Turco MA, et al., TAXUS V ISR Investigators. Two-year clinical outcomes aft er paclitaxel-eluting stent or brachytherapy treatment for bare metal stent restenosis: the TAXUS V ISR trial. Eur Heart J. 2008;29:1625-34. Epub 13 Jun 2008. (Pubitemid 351958446)
-
(2008)
European Heart Journal
, vol.29
, Issue.13
, pp. 1625-1634
-
-
Ellis, S.G.1
O'Shaughnessy, C.D.2
Martin, S.L.3
Kent, K.4
McGarry, T.5
Turco, M.A.6
Kereiakes, D.J.7
Popma, J.J.8
Friedman, M.9
Koglin, J.10
Stone, G.W.11
-
23
-
-
27644512899
-
Three-year clinical follow-up after strontium-90/yttrium-90 beta-irradiation for the treatment of in-stent coronary restenosis
-
DOI 10.1016/j.amjcard.2005.06.087, PII S0002914905013445
-
B aierl V, Baumgartner S, Pöl linger B, Leibig M, Rieber J, Kön ig A, et al. Th ree-year clinical follow-up aft er 90Sr/90Y beta-irradiation for the treatment of in-stent coronary restenosis. Am J Cardiol. 2005;96:1399-403. (Pubitemid 41566621)
-
(2005)
American Journal of Cardiology
, vol.96
, Issue.10
, pp. 1399-1403
-
-
Baierl, V.1
Baumgartner, S.2
Pollinger, B.3
Leibig, M.4
Rieber, J.5
Konig, A.6
Krotz, F.7
Sohn, H.-Y.8
Siebert, U.9
Haimerl, W.10
Duhmke, E.11
Theisen, K.12
Klauss, V.13
Schiele, T.M.14
-
24
-
-
34548221917
-
Four-year results after brachytherapy for diffuse coronary in-stent restenosis: Will coronary radiation therapy survive?
-
DOI 10.1016/j.carrev.2006.09.005, PII S155383890600234X
-
R uef J, Hofmann M, Storger H, Haase J. Four-year results aft er brachytherapy for diff use coronary in-stent restenosis: Will coronary radiation therapy survive? Cardiovasc Revasc Med. 2007;8: 170-4. (Pubitemid 47332351)
-
(2007)
Cardiovascular Revascularization Medicine
, vol.8
, Issue.3
, pp. 170-174
-
-
Ruef, J.1
Hofmann, M.2
Storger, H.3
Haase, J.4
-
25
-
-
41849098150
-
Long-term outcomes after intracoronary β-irradiation for in-stent restenosis in bare-metal stents
-
M aeder MT, Pfi sterer ME, Buser PT, Roser HW, Roth J, Weilenmann D, et al. Long-term outcomes aft er intracoronary Beta-irradiation for in-stent restenosis in bare-metal stents. J Invasive Cardiol. 2008;20:179-84. (Pubitemid 351498688)
-
(2008)
Journal of Invasive Cardiology
, vol.20
, Issue.4
, pp. 179-184
-
-
Maeder, M.T.1
Pfisterer, M.E.2
Buser, P.T.3
Roser, H.W.4
Roth, J.5
Weilenmann, D.6
Nietlispach, F.P.7
Zellweger, M.J.8
Amsler, B.9
Kaiser, C.A.10
-
26
-
-
34447634127
-
Comparison of six-month angiographic and three-year outcomes aft er sirolimus-eluting stent implantation versus brachytherapy for bare metal in-stent restenosis
-
Epub 13 Jun 2007.
-
L ee SW, Park SW, Park DW, Lee SW, Kim SH, Jang JS, et al. Comparison of six-month angiographic and three-year outcomes aft er sirolimus-eluting stent implantation versus brachytherapy for bare metal in-stent restenosis. Am J Cardiol. 2007;100:425-30. Epub 13 Jun 2007.
-
(2007)
Am. J. Cardiol.
, vol.100
, pp. 425-430
-
-
Lee, S.W.1
Park, S.W.2
Park, D.W.3
Lee, S.W.4
Kim, S.H.5
Jang, J.S.6
-
27
-
-
64449085916
-
Incidence of stent thrombosis and adverse cardiac events 5 years aft er sirolimus stent implantation in clinical practice
-
Epub 25 Mar 2009.
-
Goy JJ, Urban P, Kaufmann U, Seydoux C, De Benedetti E, Berger A. Incidence of stent thrombosis and adverse cardiac events 5 years aft er sirolimus stent implantation in clinical practice. Am Heart J. 2009;157:883-8. Epub 25 Mar 2009.
-
(2009)
Am. Heart J.
, vol.157
, pp. 883-888
-
-
Goy, J.J.1
Urban, P.2
Kaufmann, U.3
Seydoux, C.4
De Benedetti, E.5
Berger, A.6
-
28
-
-
43649091479
-
Long-Term Outcome in Patients Treated With Sirolimus-Eluting Stents in Complex Coronary Artery Lesions. 3-Year Results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) Trial
-
DOI 10.1016/j.jacc.2008.01.056, PII S0735109708009467
-
K elbaek H, Kløv gaard L, Helqvist S, Lassen JF, Krusell LR, Engstr øm T, et al. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions: 3-year results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) trial. J Am Coll Cardiol. 2008; 51:2011 - 6. (Pubitemid 351689054)
-
(2008)
Journal of the American College of Cardiology
, vol.51
, Issue.21
, pp. 2011-2016
-
-
Kelbaek, H.1
Klovgaard, L.2
Helqvist, S.3
Lassen, J.F.4
Krusell, L.R.5
Engstrom, T.6
Botker, H.E.7
Jorgensen, E.8
Saunamaki, K.9
Aljabbari, S.10
Thayssen, P.11
Galloe, A.12
Jensen, G.V.H.13
Thuesen, L.14
-
29
-
-
24044554004
-
Long-term results (three to five years) of the Restenosis Intrastent: Balloon angioplasty versus elective Stenting (RIBS) randomized study
-
DOI 10.1016/j.jacc.2005.05.050, PII S0735109705012702
-
A lfonso F, Augé JM, Zueco J, Bethencourt A, Ló p ez-Mí n guez JR, Hern á ndez JM, et al., RIBS Investigators. Long-term results (three to fi ve years) of the restenosis intrastent: Balloon angioplasty versus elective stenting (RIBS) randomized study. J Am Coll Cardiol. 2005;46:756-60. (Pubitemid 41224795)
-
(2005)
Journal of the American College of Cardiology
, vol.46
, Issue.5
, pp. 756-760
-
-
Alfonso, F.1
Auge, J.M.2
Zueco, J.3
Bethencourt, A.4
Lopez-Minguez, J.R.5
Hernandez, J.M.6
Bullones, J.A.7
Calvo, I.8
Esplugas, E.9
Perez-Vizcayno, M.J.10
Moreno, R.11
Fernandez, C.12
Hernandez, R.13
Gama-Ribeiro, V.14
-
30
-
-
55249092504
-
RIBS-II investigators longterm clinical benefi t of sirolimus-eluting stents in patients with in-stent restenosis results of the RIBS-II restenosis intra-stent: Balloon angioplasty vs elective sirolimus-eluting stenting study
-
Alfonso F, P é rez-Vizcayno MJ, Hern á ndez R, Bethencourt A, Mart í V, L ó pez-M í nguez JR, et al; RIBS-II Investigators. Longterm clinical benefi t of sirolimus-eluting stents in patients with in-stent restenosis results of the RIBS-II (restenosis intra-stent: Balloon angioplasty vs. elective sirolimus-eluting Stenting) study. J Am Coll Cardiol. 2008;52:1621-7.
-
(2008)
J. Am. Coll. Cardiol.
, vol.52
, pp. 1621-1627
-
-
Alfonso, F.1
Pérez-Vizcayno, M.J.2
Hernández, R.3
Bethencourt, A.4
Martí, V.5
López-Mínguez, J.R.6
-
31
-
-
49549111193
-
SISR investigators 3-year follow-up of the SISR sirolimus-eluting stents versus vascular brachytherapy for in-stent restenosis trial
-
H olmes DR Jr, Teirstein PS, Satler L, Sketch MH Jr, Popma JJ, Mauri L, et al., SISR Investigators. 3-year follow-up of the SISR (Sirolimus-eluting stents versus vascular brachytherapy for in-stent restenosis) trial. JACC Cardiovasc Interv. 2008;1:439-48.
-
(2008)
JACC Cardiovasc. Interv.
, vol.1
, pp. 439-448
-
-
Holmes Jr., D.R.1
Teirstein, P.S.2
Satler, L.3
Sketch Jr., M.H.4
Popma J.J.Mauri, L.5
-
32
-
-
0242418188
-
Reno, a European postmarket surveillance registry, confirms effectiveness of coronary brachytherapy in routine clinical practice
-
DOI 10.1016/S0360-3016(02)04286-4
-
O recchia R, Von Rottkay P, Coucke P, Ehnert M, Urban P, Bonan R, et al., RENO Investigators. Reno, a European postmarket surveillance registry, confi rms eff ectiveness of coronary brachytherapy in routine clinical practice. Int J Radiat Oncol Biol Phys. 2003;55: 1019-26. (Pubitemid 36287006)
-
(2003)
International Journal of Radiation Oncology Biology Physics
, vol.55
, Issue.4
, pp. 1019-1026
-
-
Coen, V.1
Serruys, P.2
Sauerwein, W.3
Orecchia, R.4
Von Rottkay, P.5
Coucke, P.6
Ehnert, M.7
Urban, P.8
Bonan, R.9
Levendag, P.10
|