Correction of frequency drifts induced by gradient heating in 1H spectra using interleaved reference spectroscopy

Author keywords

Frequency lock; Gradient heating; Interleaved reference scan; IRS; MR spectroscopy; Phase correction

Indexed keywords

WATER;

EID: 79952268582     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22471     Document Type: Article
Times cited : (31)

References (10)
  • 1
    • 0031032023 scopus 로고    scopus 로고
    • Characterization and prediction of gradient acoustic noise in MR imagers
    • DOI 10.1002/mrm.1910370103
    • Hedeen RA, Edelstein WA. Characterization and prediction of gradient acoustic noise in MR imagers. Magn Reson Med 1997;37:7-10. (Pubitemid 27008824)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.1 , pp. 7-10
    • Hedeen, R.A.1    Edelstein, W.A.2
  • 2
    • 27644557313 scopus 로고    scopus 로고
    • Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging
    • DOI 10.1002/mrm.20695
    • Foerster BU, Tomasi D, Caparelli EC. Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging. Magn Reson Med 2005;54:1261-1267. (Pubitemid 41567206)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.5 , pp. 1261-1267
    • Foerster, B.U.1    Tomasi, D.2    Caparelli, E.C.3
  • 3
    • 0034900222 scopus 로고    scopus 로고
    • Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference
    • DOI 10.1002/mrm.1203
    • Helms G, Piringer A. Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference. Magn Reson Med 2001;46:395-400. (Pubitemid 32703287)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.2 , pp. 395-400
    • Helms, G.1    Piringer, A.2
  • 5
    • 0032852406 scopus 로고    scopus 로고
    • Field-frequency locked in vivo proton MRS on a whole-body spectrometer
    • DOI 10.1002/(SICI)1522-2594(199910)42:4<636::AID-MRM4>3.0.CO;2-I
    • Henry PG, van de Moortele PF, Giacomini E, Nauerth A, Bloch G. Field-frequency locked in vivo proton MRS on a whole-body spectrometer. Magn Reson Med 1999;42:636-642. (Pubitemid 29468292)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.4 , pp. 636-642
    • Henry, P.-G.1    De Van, M.P.-F.2    Giacomini, E.3    Nauerth, A.4    Bloch, G.5
  • 6
    • 0036263892 scopus 로고    scopus 로고
    • Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: Compensation of motion artifacts and magnetic field instabilities
    • DOI 10.1002/mrm.10174
    • Thiel T, Czisch M, Elbel GK, Hennig J. Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: compensation of motion artifacts and magnetic field instabilities. Magn Reson Med 2002;47:1077-1082. (Pubitemid 34587399)
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.6 , pp. 1077-1082
    • Thiel, T.1    Czisch, M.2    Elbel, G.K.3    Hennig, J.4
  • 8
    • 0025340810 scopus 로고
    • In vivo proton spectroscopy in presence of eddy currents
    • Klose U. In vivo proton spectroscopy in presence of eddy currents. Magn Reson Med 1990;14:26-30.
    • (1990) Magn Reson Med , vol.14 , pp. 26-30
    • Klose, U.1
  • 10
    • 77949702624 scopus 로고    scopus 로고
    • Single-voxel MRS with prospective motion correction and retrospective frequency correction
    • Zaitsev M, Speck O, Hennig J, Buchert M. Single-voxel MRS with prospective motion correction and retrospective frequency correction. NMR Biomed 2010;23:325-332.
    • (2010) NMR Biomed , vol.23 , pp. 325-332
    • Zaitsev, M.1    Speck, O.2    Hennig, J.3    Buchert, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.