메뉴 건너뛰기




Volumn 25, Issue 5, 2010, Pages 313-320

Centrifugal pump inlet pressure site affects measurement

Author keywords

ECLS; ECMO; Inlet pressure; VAD; Venous line

Indexed keywords

ARTICLE; ATMOSPHERIC PRESSURE; BLOOD PRESSURE MEASUREMENT; BLOOD PUMP; CANNULA; EXTRACORPOREAL OXYGENATION; PRIORITY JOURNAL; CATHETERIZATION; EQUIPMENT DESIGN; EXTRACORPOREAL CIRCULATION; HEART ASSIST DEVICE; HUMAN; PRESSURE; STANDARD;

EID: 79952197337     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1177/0267659110376697     Document Type: Article
Times cited : (7)

References (10)
  • 1
    • 0033664688 scopus 로고    scopus 로고
    • Investigation and quantification of the blood trauma caused by the combined dynamic forces experienced during cardiopulmonary bypass
    • Mulholland JW, Massey W, Shelton JC. Investigation and quantification of the blood trauma caused by the combined dynamic forces experienced during cardiopulmonary bypass. Perfusion. 2000; 15(6): 485-494.
    • (2000) Perfusion , vol.15 , Issue.6 , pp. 485-494
    • Mulholland, J.W.1    Massey, W.2    Shelton, J.C.3
  • 3
    • 0014457405 scopus 로고
    • Hemolytic effects of energy dissipation in flowing blood
    • Bluestein M, Mockros LF. Hemolytic effects of energy dissipation in flowing blood. Med Biol Eng 1969; 7: 1-16.
    • (1969) Med Biol Eng , vol.7 , pp. 1-16
    • Bluestein, M.1    Mockros, L.F.2
  • 5
    • 0016556004 scopus 로고
    • The effects of subatmospheric pressure on the hemolysis of blood
    • Wielgorski JW, Cross DE, Nwadike EVO. The effects of subatmospheric pressure on the hemolysis of blood. J Biotech 1975; 8: 321-25.
    • (1975) J Biotech , vol.8 , pp. 321-325
    • Wielgorski, J.W.1    Cross, D.E.2    Nwadike, E.V.O.3
  • 6
    • 0036776095 scopus 로고    scopus 로고
    • Cavitation versus degassing: In vitro study of the microbubble phenomenon observed during echocardiography in patients with mechanical prosthetic cardiac valves
    • Girod G, Jaussi A, Rosset C, De Werra P, Hirt F. Kappen-berger L. In vitro study of the microbubble phenomenon observed during echocardiography in patients with mec-hanical prosthetic cardiac valves. Echocardiography 2002; 19(7): 531-536. (Pubitemid 35253403)
    • (2002) Echocardiography , vol.19 , Issue.7 , pp. 531-536
    • Girod, G.1    Jaussi, A.2    Rosset, C.3    De Werra, P.4    Hirt, F.5    Kappenberger, L.6
  • 8
    • 0032850024 scopus 로고    scopus 로고
    • Laboratory testing of femoral venous cannulae: Effect of size, position and negative pressure on flow
    • Kurusz M, Deyo D, Sholar A, Tao W, Zwischenberger J. Laboratory testing of femoral venous cannulae: effect of size, position and negative pressure on flow. Perfusion 1999; 14: 379-387. (Pubitemid 29423928)
    • (1999) Perfusion , vol.14 , Issue.5 , pp. 379-387
    • Kurusz, M.1    Deyo, D.J.2    Sholar, A.D.3    Tao, W.4    Zwischenberger, J.B.5
  • 9
    • 0031921951 scopus 로고    scopus 로고
    • In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump
    • DOI 10.1046/j.1525-1594.1998.06142.x
    • Araki K, Anai H, Oshikawa M, Nakamura K, Onitsuka T. In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump. Artificial Organs 1998; 22(5): 366-370. (Pubitemid 28222293)
    • (1998) Artificial Organs , vol.22 , Issue.5 , pp. 366-370
    • Araki, K.1    Anai, H.2    Oshikawa, M.3    Nakamura, K.4    Onitsuka, T.5
  • 10
    • 0028889513 scopus 로고
    • Hemolysis and heat generation in six different types of centrifugal pumps
    • Araki K, Taenaka Y, Masuzawa T, et al. Hemolysis and heat generation in six different types of centrifugal pumps. Artificial Organs 1995; 19(9): 928-932.
    • (1995) Artificial Organs , vol.19 , Issue.9 , pp. 928-932
    • Araki, K.1    Taenaka, Y.2    Masuzawa, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.