메뉴 건너뛰기




Volumn 26, Issue 3, 2011, Pages 1112-1113

Troponin levels in hemodialysis patients: Interpretation based on guidelines, changing concentrations and high-sensitivity assays

Author keywords

[No Author keywords available]

Indexed keywords

TROPONIN I;

EID: 79952152941     PISSN: 09310509     EISSN: 14602385     Source Type: Journal    
DOI: 10.1093/ndt/gfq736     Document Type: Letter
Times cited : (2)

References (5)
  • 2
    • 67650800267 scopus 로고    scopus 로고
    • Haemodialysis patients longitudinally assessed by highly sensitive cardiac troponin T and commercial cardiac troponin T and cardiac troponin I assays
    • Jacobs LH, van de Kerkhof J, Mingels AM et al. Haemodialysis patients longitudinally assessed by highly sensitive cardiac troponin T and commercial cardiac troponin T and cardiac troponin I assays. Ann Clin Biochem 2009;46:283-290
    • (2009) Ann. Clin. Biochem. , vol.46 , pp. 283-290
    • Jacobs, L.H.1    Van De Kerkhof, J.2    Mingels, A.M.3
  • 3
    • 79551488250 scopus 로고    scopus 로고
    • Troponin I levels in asymptomatic patients on haemodialysis using a high-sensitivity assay
    • Kumar N, Michelis MF, De Vita MV et al. Troponin I levels in asymptomatic patients on haemodialysis using a high-sensitivity assay. Nephrol Dial Transplant 2010;26:665-670
    • (2010) Nephrol. Dial Transplant , vol.26 , pp. 665-670
    • Kumar, N.1    Michelis, M.F.2    De Vita, M.V.3
  • 4
    • 65949119138 scopus 로고    scopus 로고
    • Role of monitoring changes in sensitive cardiac troponin I assay results for early diagnosis of myocardial infarction and prediction of risk of adverse events
    • Apple FS, Pearce LA, Smith SW et al. Role of monitoring changes in sensitive cardiac troponin I assay results for early diagnosis of myocardial infarction and prediction of risk of adverse events. Clin Chem 2009;55:930-937
    • (2009) Clin. Chem. , vol.55 , pp. 930-937
    • Apple, F.S.1    Pearce, L.A.2    Smith, S.W.3
  • 5
    • 77956169824 scopus 로고    scopus 로고
    • High sensitivity cardiac troponin concentration cutoffs-is a healthy population the right reference population for thosewith underlying cardiac disease
    • Kavsak PA, McQueen MJ. High sensitivity cardiac troponin concentration cutoffs-is a healthy population the right reference population for thosewith underlying cardiac disease. Clin Biochem 2010;43:1037-1038
    • (2010) Clin. Biochem. , vol.43 , pp. 1037-1038
    • Kavsak, P.A.1    McQueen, M.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.