메뉴 건너뛰기




Volumn 688, Issue , 2011, Pages 67-74

Long-PCR Amplification of Human Genomic DNA

Author keywords

DNA polymerase; F8 gene; Long PCR; Polymerase chain reaction; Primer design

Indexed keywords

BLOOD CLOTTING FACTOR 8; DNA; F8 PROTEIN, HUMAN;

EID: 79952117213     PISSN: 10643745     EISSN: 19406029     Source Type: Book Series    
DOI: 10.1007/978-1-60761-947-5_6     Document Type: Chapter
Times cited : (4)

References (7)
  • 2
    • 0028211009 scopus 로고
    • PCR amplification of up to 35-kb DNA with high fidelity and high yield from lambda bacteriophage templates
    • Barnes W. M. (1994) PCR amplification of up to 35-kb DNA with high fidelity and high yield from lambda bacteriophage templates. Proc Natl Acad Sci USA 91, 2216–20.
    • (1994) Proc Natl Acad Sci USA , vol.91 , pp. 2216-2220
    • Barnes, W.M.1
  • 3
    • 0028261194 scopus 로고
    • Effective amplification of long targets from cloned inserts and human genomic DNA
    • Cheng S., Fockler C., Barnes W. M., and Higuchi R. (1994) Effective amplification of long targets from cloned inserts and human genomic DNA. Proc Natl Acad Sci USA 91, 5695–99.
    • (1994) Proc Natl Acad Sci USA , vol.91 , pp. 5695-5699
    • Cheng, S.1    Fockler, C.2    Barnes, W.M.3    Higuchi, R.4
  • 4
    • 85139066749 scopus 로고    scopus 로고
    • Liu Q., Nozari G., and Sommer S. S. (1998) Single-tube polymerase chain reaction for rapid diagnosis of the inversion hotspot of mutation in hemophilia A. Blood 92, 1458–9. Erratum in Blood (1999) 93, 2141.
    • Liu Q., Nozari G., and Sommer S. S. (1998) Single-tube polymerase chain reaction for rapid diagnosis of the inversion hotspot of mutation in hemophilia A. Blood 92, 1458–9. Erratum in Blood (1999) 93, 2141.
  • 5
    • 0032431385 scopus 로고    scopus 로고
    • Subcycling-PCR for multiplex long distance amplification of regions with high and low GC content: Application to the inversion hotspot in the FVIII gene
    • Liu Q. and Sommer S. S. (1998) Subcycling-PCR for multiplex long distance amplification of regions with high and low GC content: application to the inversion hotspot in the FVIII gene. Biotechniques 25, 1022–28.
    • (1998) Biotechniques , vol.25 , pp. 1022-1028
    • Liu, Q.1    Sommer, S.S.2
  • 6
    • 0027520025 scopus 로고
    • Inversions disrupting the factor VIII gene are a common cause of severe haemophilia A
    • Lakich D., Kazazian H. H. Jr, Antonarakis S. E., and Gitschier J. (1993) Inversions disrupting the factor VIII gene are a common cause of severe haemophilia A. Nat Genet 5, 236–41.
    • (1993) Nat Genet , vol.5 , pp. 236-241
    • Lakich, D.1    Kazazian, H.H.2    Antonarakis, S.E.3    Gitschier, J.4
  • 7
    • 85139010312 scopus 로고    scopus 로고
    • Primer 3 URL: http://primer3.sourceforge. net/webif.php.
    • Primer 3 URL: http://primer3.sourceforge. net/webif.php.