메뉴 건너뛰기




Volumn 76, Issue 3, 2010, Pages 399-403

Electronystagmography versus videonystagmography

Author keywords

Electronystagmography; Eye movements; Nystagmus; Pathologic

Indexed keywords

COMPARATIVE STUDY; ELECTRONYSTAGMOGRAPHY; ELECTROOCULOGRAPHY; HUMAN; INSTRUMENTATION; METHODOLOGY; REVIEW; SENSITIVITY AND SPECIFICITY; VESTIBULAR DISORDER; VIDEORECORDING;

EID: 79952111659     PISSN: 18088694     EISSN: 18088686     Source Type: Journal    
DOI: 10.1590/S1808-86942010000300021     Document Type: Review
Times cited : (44)

References (35)
  • 1
    • 0014021633 scopus 로고
    • Electronystagmography: Its clinical application
    • Farkashidy J. Electronystagmography: Its clinical application. Can Med Assoc J. 1966;94:368-72.
    • (1966) Can Med Assoc J. , vol.94 , pp. 368-372
    • Farkashidy, J.1
  • 4
    • 0029946987 scopus 로고    scopus 로고
    • Assessment: Electronystagmography
    • Therapeutics and Technology Assessment Subcommittee
    • Therapeutics and Technology Assessment Subcommittee. Assessment: electronystagmography. Neurology. 1996;46(6):1763-6.
    • (1996) Neurology , vol.46 , Issue.6 , pp. 1763-1766
  • 7
    • 0022338856 scopus 로고
    • The pitfalls of limiting ENG testing to patients with vertigo
    • Keim RJ. The pitfalls of limiting ENG testing to patients with vertigo. Laryngoscope. 1985;95(10):1208-12. (Pubitemid 16228721)
    • (1985) Laryngoscope , vol.95 , Issue.10 , pp. 1208-1212
    • Keim, R.J.1
  • 8
    • 0032974837 scopus 로고    scopus 로고
    • Current status of electronystagmography testing
    • DOI 10.1016/S0194-5998(99)70286-X
    • Bhansali SA, Honrubia V. Current status of electronystagmography testing. Otolaryngol Head Neck Surg. 1999;120(3):419-26. (Pubitemid 29135881)
    • (1999) Otolaryngology - Head and Neck Surgery , vol.120 , Issue.3 , pp. 419-426
    • Bhansali, S.A.1    Honrubia, V.2
  • 9
    • 0032216627 scopus 로고    scopus 로고
    • Video-oculography as part of the ENG battery
    • Eckert AM, Gizzi M. Video-oculography as part of the ENG battery. Br J Audiol. 1998;32(6):411-6.
    • (1998) Br J Audiol. , vol.32 , Issue.6 , pp. 411-416
    • Eckert, A.M.1    Gizzi, M.2
  • 10
    • 0027931093 scopus 로고
    • A review of computerized electronystagmography technology
    • Houston HG, Watson DR. A review of computerized electronystagmography technology. Br J Audiol. 1994;28:41-6. (Pubitemid 24252011)
    • (1994) British Journal of Audiology , vol.28 , Issue.1 , pp. 41-46
    • Houston, H.G.1    Watson, D.R.2
  • 12
    • 85031268772 scopus 로고    scopus 로고
    • Schaumburg, Illinois: GN Otometrics
    • Stockwell CW. Introduction to ENG. Schaumburg, Illinois: GN Otometrics; 2004. p.32.
    • (2004) Introduction to ENG. , pp. 32
    • Stockwell, C.W.1
  • 16
    • 34249751197 scopus 로고    scopus 로고
    • Eye movement recordings: Methods
    • Eggert T.Eye movement recordings: methods. Dev Ophthalmol. 2007;40:15-34.
    • (2007) Dev Ophthalmol. , vol.40 , pp. 15-34
    • Eggert, T.1
  • 17
    • 37149025326 scopus 로고    scopus 로고
    • Vértigo posicional
    • Bartual Pastor J, Pérez Fernandez N. El sistema vestibular y sus alteraciones. Barcelona: Masson
    • Pérez Fernandez N, Pastor Fortea MJ. Vértigo posicional. In: Bartual Pastor J, Pérez Fernandez N. El sistema vestibular y sus alteraciones. Tomo II. Patología. Barcelona: Masson; 1999. p.341-50.
    • (1999) Tomo II. Patología , pp. 341-350
    • Pérez Fernandez, N.1    Pastor Fortea, M.J.2
  • 18
    • 70450158893 scopus 로고    scopus 로고
    • Relative diagnostic importance of electronystagmography and magnetic resonance imaging in vestibular disorders
    • Korres S, Riga M, Papacharalampous G, Chimona T, Danielidis V, Korres G, Xenellis J. Relative diagnostic importance of electronystagmography and magnetic resonance imaging in vestibular disorders. J Laryngol Otol. 2009;123(8):851-6.
    • (2009) J Laryngol Otol. , vol.123 , Issue.8 , pp. 851-856
    • Korres, S.1    Riga, M.2    Papacharalampous, G.3    Chimona, T.4    Danielidis, V.5    Korres, G.6    Xenellis, J.7
  • 20
    • 0015295306 scopus 로고
    • New possibilities of analysis in electronystagmography
    • Padovan I, Pansini M. New possibilities of analysis in electronystagmography. Acta Otolaryng (Stockh). 1972;73:121-5.
    • (1972) Acta Otolaryng (Stockh) , vol.73 , pp. 121-125
    • Padovan, I.1    Pansini, M.2
  • 21
    • 0014473207 scopus 로고
    • Three derivations in electronystagmography
    • (Stockh)
    • Pansini M, Padovan I. Three derivations in electronystagmography. Acta Otolaryng (Stockh). 1969;67:303-9.
    • (1969) Acta Otolaryng , vol.67 , pp. 303-309
    • Pansini, M.1    Padovan, I.2
  • 22
    • 17144474134 scopus 로고
    • Nouvelles possibilités des analyses dans l'electronystagmographie
    • (Bordeaux)
    • Pansini M, Padovan I, Gospodnetic R, Ribaric K. Nouvelles possibilités des analyses dans l'electronystagmographie. Rev Laryng (Bordeaux). 1970;11/12: 973-95.
    • (1970) Rev Laryng , vol.11-12 , pp. 973-995
    • Pansini, M.1    Padovan, I.2    Gospodnetic, R.3    Ribaric, K.4
  • 26
    • 79955111834 scopus 로고    scopus 로고
    • Vestibular testing
    • Glasscock ME, Aina JG. 5th ed., Connecticut: PMPH-USA Medical
    • Bojrab DI, Maya Kato B. Vestibular testing. In: Glasscock ME, Aina JG. Glasscock-Shambaugh surgery of the ear. 5th ed., Connecticut: PMPH-USA Medical; 2003. p. 201-20.
    • (2003) Glasscock-Shambaugh Surgery of the Ear , pp. 201-220
    • Bojrab, D.I.1    Maya Kato, B.2
  • 27
    • 79955107769 scopus 로고    scopus 로고
    • Videonystagmography versus electronystagmography: Advantages and disadvantages
    • Boniver R. Videonystagmography versus electronystagmography: advantages and disadvantages. Neurootology Newsletter. 1998;3(1):109-10.
    • (1998) Neurootology Newsletter , vol.3 , Issue.1 , pp. 109-110
    • Boniver, R.1
  • 29
    • 1642496837 scopus 로고    scopus 로고
    • Benign paroxysmal positioning vertigo: Diagnosis and therapy using video-oculographic control
    • DOI 10.1159/000075229
    • Yakinthou A, Maurer J, Mann W. Benign paroxysmal positioning vertigo: diagnosis and therapy using video-oculographic control. ORL J Otorhinolaryngol Relat Spec. 2003;65(5):290-4. (Pubitemid 38134876)
    • (2003) ORL , vol.65 , Issue.5 , pp. 290-294
    • Yakinthou, A.1    Maurer, J.2    Mann, W.3
  • 33
    • 79955105694 scopus 로고    scopus 로고
    • Atlas de pruebas vestibulares para especialistas en otorrinolaringologia
    • Pérez N. Atlas de pruebas vestibulares para especialistas en otorrinolaringologia. Barcelona: Profármaco.2; 2009p. 207.
    • (2009) Barcelona: Profármaco , vol.2 , pp. 207
    • Pérez, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.