메뉴 건너뛰기




Volumn 2010, Issue 572 CP, 2010, Pages

Observability analysis for power systems including conventional and phasor measurements

Author keywords

Flow islands; Gram matrix; Observability restoration; Phasor measurement units; Triangular factors

Indexed keywords

BOUNDARY BUS; BRANCH CURRENTS; BUS SYSTEMS; BUS VOLTAGE; CONVENTIONAL MEASUREMENTS; DIRECT METHOD; FLOW ISLANDS; GRAM MATRICES; GRAM MATRIX; INJECTION MEASUREMENT; JACOBIANS; MEASUREMENT SYSTEM; OBSERVABILITY ANALYSIS; PHASOR MEASUREMENT UNIT; PHASOR MEASUREMENT UNITS; PHASOR MEASUREMENTS; POWER SYSTEMS; REDUCED ORDER; REDUCED SIZE; TRIANGULAR FACTORIZATION; TRIANGULAR FACTORS; UNOBSERVABLE;

EID: 79952030111     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1049/cp.2010.0892     Document Type: Conference Paper
Times cited : (5)

References (12)
  • 1
    • 0022060812 scopus 로고
    • NETWORK OBSERVABILITY: IDENTIFICATION OF OBSERVABLE ISLANDS AND MEASUREMENT PLACEMENT.
    • A. Monticelli and F. F. Wu, "Network Observability: Identification of Observable Islands and Measurement Placement, " IEEE Trans. Power App. Syst., vol. PAS-104, no. 5, pp. 1035-1041, May 1985. (Pubitemid 15476791)
    • (1985) IEEE transactions on power apparatus and systems , vol.PAS-104 , Issue.5 , pp. 1035-1041
    • Monticelli, A.1    Wu Felix, F.2
  • 2
    • 0024104199 scopus 로고
    • A reduced model for power system observability analysis and restoration
    • Nov.
    • G. C. Contaxis and G. N. Korres, "A Reduced Model for Power System Observability Analysis and Restoration, " IEEE Trans. Power Syst., vol. 3, no. 4, pp. 1411-1417, Nov. 1988.
    • (1988) IEEE Trans. Power Syst. , vol.3 , Issue.4 , pp. 1411-1417
    • Contaxis, G.C.1    Korres, G.N.2
  • 3
    • 0027589817 scopus 로고
    • Power system observability with minimal phaser measurement placement
    • DOI 10.1109/59.260810
    • T. L. Baldwin, L. Mili, M. B. Boisen, Jr, and R. Adapa, "Power system observability with minimal phasor measurement placement, " IEEE Trans. Power Syst., vol. 8, no. 2, pp. 707-715, May 1993. (Pubitemid 23699295)
    • (1993) IEEE Transactions on Power Systems , vol.8 , Issue.2 , pp. 707-715
    • Balwin, T.L.1    Mili, L.2    Adapa, R.3    Boisen Jr., M.B.4
  • 4
    • 27844462056 scopus 로고    scopus 로고
    • Phasor measurement unit placement techniques for complete and incomplete observability
    • DOI 10.1109/TPWRD.2005.855457
    • R. F. Nuqui and A. G. Phadke, "Phasor measurement unit placement techniques for complete and incomplete observability, " IEEE Trans. Power Del., vol. 20, no. 4, pp. 2381-2388, Oct. 2005. (Pubitemid 41638211)
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.4 , pp. 2381-2388
    • Nuqui, R.F.1    Phadke, A.G.2
  • 5
    • 33847645050 scopus 로고    scopus 로고
    • Placement of PMUs to enable bad data detection in state estimation
    • DOI 10.1109/TPWRS.2006.881149
    • J. Chen and A. Abur, "Placement of PMUs to enable bad data detection in state estimation, " IEEE Trans. Power Syst., vol. 21, no. 4, pp. 1608- 1615, Nov. 2006. (Pubitemid 46357759)
    • (2006) IEEE Transactions on Power Systems , vol.21 , Issue.4 , pp. 1608-1615
    • Chen, J.1    Abur, A.2
  • 6
    • 49249129678 scopus 로고    scopus 로고
    • Generalized integer linear programming formulation for optimal PMU placement
    • Aug.
    • B. Gou, "Generalized Integer Linear Programming Formulation for Optimal PMU Placement, " IEEE Trans. Power Syst., vol. 23, no. 3, pp. 1099-1104, Aug. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.3 , pp. 1099-1104
    • Gou, B.1
  • 7
    • 49249129032 scopus 로고    scopus 로고
    • Optimal placement of phasor measurement units for power system observability
    • Aug.
    • S. Chakrabarti and E. Kyriakides, "Optimal Placement of Phasor Measurement Units for Power System Observability, " IEEE Trans. Power Syst., vol. 23, no. 3, pp. 1433-1440, Aug. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.3 , pp. 1433-1440
    • Chakrabarti, S.1    Kyriakides, E.2
  • 8
    • 49249087872 scopus 로고    scopus 로고
    • Optimal placement of PMUs by integer linear programming
    • Aug.
    • B. Gou, "Optimal placement of PMUs by integer linear programming, " IEEE Trans. Power Syst., vol. 23, no. 3, pp. 1525-1526, Aug. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.3 , pp. 1525-1526
    • Gou, B.1
  • 9
    • 39749164601 scopus 로고    scopus 로고
    • On the use of Gram matrix in observability analysis
    • DOI 10.1109/TPWRS.2007.913731
    • M. C. de Almeida, E. N. Asada, and A. V. Garcia, "On the use of Gram matrix in observability analysis, " IEEE Trans. Power Syst., vol. 23, no. 1, pp. 249-251, Feb. 2008. (Pubitemid 351292108)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.1 , pp. 249-251
    • De Almeida, M.C.1    Asada, E.N.2    Garcia, A.V.3
  • 10
    • 70350534834 scopus 로고    scopus 로고
    • Power system observability analysis based on gram matrix and minimum norm solution
    • Nov.
    • M. C. de Almeida, E. N. Asada, and A. V. Garcia, "Power System Observability Analysis Based on Gram Matrix and Minimum Norm Solution, " IEEE Trans. Power Syst., vol. 23, no. 4, pp. 1611-1618, Nov. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.4 , pp. 1611-1618
    • De Almeida, M.C.1    Asada, E.N.2    Garcia, A.V.3
  • 12
    • 39749131043 scopus 로고
    • Gram-Schmidt orthogonalization by Gauss elimination
    • June/Jul.
    • L. Pursell and S. Y. Trimble, "Gram-Schmidt orthogonalization by Gauss elimination, " Amer. Math. Monthly, vol. 98, no. 6, pp. 544-549, June/Jul. 1991.
    • (1991) Amer. Math. Monthly , vol.98 , Issue.6 , pp. 544-549
    • Pursell, L.1    Trimble, S.Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.