메뉴 건너뛰기




Volumn 35, Issue 4, 2011, Pages 700-705

Exergy analysis for quasi two-stage compression heat pump system coupled with ejector

Author keywords

Ejector; Exergy; Heat pump; Scroll compressor

Indexed keywords

EJECTOR; EXERGETIC EFFICIENCY; EXERGY ANALYSIS; EXERGY LOSS; EXPERIMENTAL DATA; FLUID PRESSURES; HEAT PUMPS; HIGH PRESSURE; MECHANICAL COMPONENTS; SECOND LAW OF THERMODYNAMICS; THERMAL ANALYSIS; TWO STAGE COMPRESSION;

EID: 79951958874     PISSN: 08941777     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.expthermflusci.2011.01.004     Document Type: Article
Times cited : (40)

References (12)
  • 1
    • 0021629443 scopus 로고
    • Heat pump room air-conditioner using variable capacity compressor
    • a
    • Umezu K., Suma S. Heat pump room air-conditioner using variable capacity compressor. ASHRAE Transactions 1984, 90(a):335-345.
    • (1984) ASHRAE Transactions , vol.90 , pp. 335-345
    • Umezu, K.1    Suma, S.2
  • 2
    • 0037211454 scopus 로고    scopus 로고
    • Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor
    • Cho Honghyun, Chung Jin Taek, Kim Yongchan Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor. International Journal of Refrigeration 2003, 26:87-94.
    • (2003) International Journal of Refrigeration , vol.26 , pp. 87-94
    • Cho, H.1    Chung, J.T.2    Kim, Y.3
  • 3
    • 0035452618 scopus 로고    scopus 로고
    • An investigation of the performance of a scroll compressor under liquid refrigerant injection
    • Dutta Asit K., Yanagisawa Tadashi, Fukuta Mitsuhiro An investigation of the performance of a scroll compressor under liquid refrigerant injection. International Journal of Refrigeration 2001, 24:577-587.
    • (2001) International Journal of Refrigeration , vol.24 , pp. 577-587
    • Dutta, A.K.1    Yanagisawa, T.2    Fukuta, M.3
  • 4
    • 33845215651 scopus 로고    scopus 로고
    • Design of experiment bench and internal pressure measurement of scroll compressor with refrigerant injection
    • Wang Baolong, Li Xianting, Shi Wenxing, Yan Qisen Design of experiment bench and internal pressure measurement of scroll compressor with refrigerant injection. International Journal of Refrigeration 2007, 30:179-186.
    • (2007) International Journal of Refrigeration , vol.30 , pp. 179-186
    • Wang, B.1    Li, X.2    Shi, W.3    Yan, Q.4
  • 5
    • 33745662411 scopus 로고    scopus 로고
    • Experiment study on heat pump system with scroll compressor flash tank
    • Huixia Zhao, Siguang Liu, Zhongbao Liu, Guoyuan Ma Experiment study on heat pump system with scroll compressor flash tank. Acta Energiae Solaris Sinica 2006, 27(5):377-381.
    • (2006) Acta Energiae Solaris Sinica , vol.27 , Issue.5 , pp. 377-381
    • Huixia, Z.1    Siguang, L.2    Zhongbao, L.3    Guoyuan, M.4
  • 6
    • 0036462726 scopus 로고    scopus 로고
    • Experimental analysis and simplified modeling of a hermetic scroll refrigeration compressor
    • Winandy Eric, Claudio Saavedra O., Lebrun Jean Experimental analysis and simplified modeling of a hermetic scroll refrigeration compressor. Applied Thermal Engineering 2002, 22:107-120.
    • (2002) Applied Thermal Engineering , vol.22 , pp. 107-120
    • Winandy, E.1    Claudio Saavedra, O.2    Lebrun, J.3
  • 7
    • 58549107212 scopus 로고    scopus 로고
    • Mathematical model of bypass behaviors used in scroll compressor
    • Liu Yangguang, Hung Chinghua, Chang Yuchoung Mathematical model of bypass behaviors used in scroll compressor. Applied Thermal Engineering 2008, 29:1058-1066.
    • (2008) Applied Thermal Engineering , vol.29 , pp. 1058-1066
    • Liu, Y.1    Hung, C.2    Chang, Y.3
  • 8
    • 79951952587 scopus 로고    scopus 로고
    • Pang Zongzhan, Ma Guoyuan, Yu Lihua. Experimental study on quasi two-stage compression heat pump system coupled with ejector, in: 22nd International Congress of Refrigeration, Beijing
    • Pang Zongzhan, Ma Guoyuan, Yu Lihua. Experimental study on quasi two-stage compression heat pump system coupled with ejector, in: 22nd International Congress of Refrigeration, Beijing, 2007, pp. 542-548.
    • (2007) , pp. 542-548
  • 9
    • 33847163621 scopus 로고    scopus 로고
    • Exergetic optimization of a key design parameter in heat pump system with economizer coupled with scroll compressor
    • Guoyuan Ma, Xianguo Li Exergetic optimization of a key design parameter in heat pump system with economizer coupled with scroll compressor. Energy Conversion and Management 2007, 48:1150-1159.
    • (2007) Energy Conversion and Management , vol.48 , pp. 1150-1159
    • Guoyuan, M.1    Xianguo, L.2
  • 10
    • 28244492800 scopus 로고    scopus 로고
    • Numerical assessment of ejector operation for refrigeration applications based on CFD
    • Bartosiewicz Y., Aidoun a Z., Mercadier Y. Numerical assessment of ejector operation for refrigeration applications based on CFD. Applied Thermal Engineering 2006, 26:604-612.
    • (2006) Applied Thermal Engineering , vol.26 , pp. 604-612
    • Bartosiewicz, Y.1    Aidoun a, Z.2    Mercadier, Y.3
  • 11
    • 79951959436 scopus 로고
    • Ye{cyrillic}.Ya{cyrillic}. Sokolov. Ejector, Translated by Huang Qiuyun, Science Press, Beijing, (in Chinese)
    • Ye{cyrillic}.Ya{cyrillic}. Sokolov. Ejector, Translated by Huang Qiuyun, Science Press, Beijing, 1977, pp. 1-132 (in Chinese).
    • (1977) , pp. 1-132


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.