메뉴 건너뛰기




Volumn 47, Issue 2, 2011, Pages 163-180

An assessment of models for predicting refrigerant characteristics in adiabatic and non-adiabatic capillary tubes

Author keywords

[No Author keywords available]

Indexed keywords

FRICTION FACTORS; NON-ADIABATIC CAPILLARY TUBE; SIMULATION RESULT; SUCTION LINE HEAT EXCHANGER; SUCTION PIPE; VAPOR COMPRESSION REFRIGERATION SYSTEM;

EID: 79951955449     PISSN: 09477411     EISSN: 14321181     Source Type: Journal    
DOI: 10.1007/s00231-010-0697-0     Document Type: Article
Times cited : (27)

References (30)
  • 1
    • 0002905865 scopus 로고
    • Characteristics of refrigerant flow in capillary tube
    • H Koizumi K Yokoyama 1980 Characteristics of refrigerant flow in capillary tube ASHRAE Trans 86 19 27
    • (1980) ASHRAE Trans , vol.86 , pp. 19-27
    • Koizumi, H.1    Yokoyama, K.2
  • 2
    • 0000192077 scopus 로고
    • A correlation for meta-stable flow of refrigerant 12 through capillary tubes
    • ZH Chen RY Li S Lin ZY Chen 1990 A correlation for meta-stable flow of refrigerant 12 through capillary tubes ASHRAE Trans 96 550 554
    • (1990) ASHRAE Trans , vol.96 , pp. 550-554
    • Chen, Z.H.1    Li, R.Y.2    Lin, S.3    Chen, Z.Y.4
  • 5
    • 0031699375 scopus 로고    scopus 로고
    • A generalized performance prediction method for adiabatic capillary tubes
    • RR Bittle DA Wolf MB Pate 1998 A generalized performance prediction method for adiabatic capillary tubes HVAC&R Res 4 27 44
    • (1998) HVAC&R Res , vol.4 , pp. 27-44
    • Bittle, R.R.1    Wolf, D.A.2    Pate, M.B.3
  • 7
    • 0036836574 scopus 로고    scopus 로고
    • Non-adiabatic capillary tube flow: A homogeneous model and process description
    • 10.1016/S1359-4311(02)00110-2
    • B Xu PK Bansal 2002 Non-adiabatic capillary tube flow: A homogeneous model and process description Appl Therm Eng 22 1801 1819 10.1016/S1359-4311(02) 00110-2
    • (2002) Appl Therm Eng , vol.22 , pp. 1801-1819
    • Xu, B.1    Bansal, P.K.2
  • 8
    • 34247500359 scopus 로고    scopus 로고
    • Numerical simulation of non-adiabatic capillary tubes considering metastable region, part I: Mathematical formulation and numerical model
    • 10.1016/j.ijrefrig.2006.08.015
    • O Garcia-Valladares 2002 Numerical simulation of non-adiabatic capillary tubes considering metastable region, part I: mathematical formulation and numerical model Int J Refrig 30 642 653 10.1016/j.ijrefrig.2006.08.015
    • (2002) Int J Refrig , vol.30 , pp. 642-653
    • Garcia-Valladares, O.1
  • 9
    • 79951943669 scopus 로고    scopus 로고
    • An evaluation of constituent correlations for predicting refrigerant characteristics in adiabatic capillary tubes
    • in press
    • Sarker D, Kim L, Son K, Jeong JH (2010) An evaluation of constituent correlations for predicting refrigerant characteristics in adiabatic capillary tubes. Int J Air-Cond Refrig (in press)
    • (2010) Int J Air-Cond Refrig
    • Sarker, D.1    Kim, L.2    Son, K.3    Jeong, J.H.4
  • 10
    • 57749093129 scopus 로고    scopus 로고
    • Experimental and numerical investigation of the flow of R-134a through lateral type diabatic capillary tube
    • MK Khan R Kumar PK Sahoo 2008 Experimental and numerical investigation of the flow of R-134a through lateral type diabatic capillary tube HVAC&R Res 14 6 871 904
    • (2008) HVAC&R Res , vol.14 , Issue.6 , pp. 871-904
    • Khan, M.K.1    Kumar, R.2    Sahoo, P.K.3
  • 11
    • 0000301867 scopus 로고
    • Turbulent flow in pipes with particular reference to the transition between the smooth and rough pipe laws
    • Colebrook CF (1939) Turbulent flow in pipes with particular reference to the transition between the smooth and rough pipe laws. J Inst Civil Eng Lond 11:133-156
    • (1939) J Inst Civil Eng Lond , vol.11 , pp. 133-156
    • Colebrook, C.F.1
  • 12
    • 0017769439 scopus 로고
    • Frictional equation spans all fluid flow regimes
    • SW Churchill 1977 Frictional equation spans all fluid flow regimes Chem Eng 84 91 92
    • (1977) Chem Eng , vol.84 , pp. 91-92
    • Churchill, S.W.1
  • 13
    • 0030312032 scopus 로고    scopus 로고
    • A theoretical model for predicting adiabatic capillary tube performance with alternative refrigerants
    • RR Bittle MB Pate 1996 A theoretical model for predicting adiabatic capillary tube performance with alternative refrigerants ASHRAE Trans 102 52 64
    • (1996) ASHRAE Trans , vol.102 , pp. 52-64
    • Bittle, R.R.1    Pate, M.B.2
  • 14
    • 0000744097 scopus 로고
    • Vaporization inside horizontal tubes benzene-oil mixtures
    • WH McAdams WK Wood RL Bryan 1942 Vaporization inside horizontal tubes benzene-oil mixtures J Heat Transf 64 193 200
    • (1942) J Heat Transf , vol.64 , pp. 193-200
    • McAdams, W.H.1    Wood, W.K.2    Bryan, R.L.3
  • 15
    • 0000813269 scopus 로고
    • Two-phase cooling experiments-pressure drop, heat transfer and burnout measurements
    • Cicchitti A, Lombardi M, Silverstri G, Soldaini R, Zavattarelli (1960) Two-phase cooling experiments-pressure drop, heat transfer and burnout measurements. Energia Nucl 7:407-425
    • (1960) Energia Nucl , vol.7 , pp. 407-425
    • Cicchitti, A.1    Lombardi, M.2    Silverstri, G.3    Soldaini, R.4    Zavattarelli5
  • 16
    • 84984087411 scopus 로고
    • Pressure drop and hold-up in two-phase flow. Part A-A comparison of existing correlation, part B-An approach through similarity analysis
    • 10.1002/aic.690100117
    • AE Dukler M Wicks RG Cleveland 1964 Pressure drop and hold-up in two-phase flow. Part A-A comparison of existing correlation, part B-An approach through similarity analysis AIChE J 10 38 51 10.1002/aic.690100117
    • (1964) AIChE J , vol.10 , pp. 38-51
    • Dukler, A.E.1    Wicks, M.2    Cleveland, R.G.3
  • 17
    • 0026051053 scopus 로고
    • Local frictional pressure drop during vaporization of R-12 through capillary tubes
    • 1134.76596 10.1016/0301-9322(91)90072-B
    • S Lin CCK Kwok RY Li 1991 Local frictional pressure drop during vaporization of R-12 through capillary tubes Int J Multiph Flow 17 95 102 1134.76596 10.1016/0301-9322(91)90072-B
    • (1991) Int J Multiph Flow , vol.17 , pp. 95-102
    • Lin, S.1    Kwok, C.C.K.2    Li, R.Y.3
  • 18
    • 0001975490 scopus 로고
    • Proposed correlation of data for isothermal two-phase two-component flow in pipes
    • RW Lockhart RC Martinelli 1949 Proposed correlation of data for isothermal two-phase two-component flow in pipes Chem Eng Progn 45 1 39 48
    • (1949) Chem Eng Progn , vol.45 , Issue.1 , pp. 39-48
    • Lockhart, R.W.1    Martinelli, R.C.2
  • 19
    • 0003212069 scopus 로고
    • Improved friction pressure drop correlation for horizontal and vertical two-phase pipe flow
    • Ispra, Italy
    • Friedel L (1979) Improved friction pressure drop correlation for horizontal and vertical two-phase pipe flow. European two-phase group meeting, Paper E2, Ispra, Italy
    • (1979) European Two-phase Group Meeting, Paper E2
    • Friedel, L.1
  • 20
    • 33845666608 scopus 로고
    • Multiphase flow and pressure drop
    • Hewitt GF (ed) Hemisphere, Washington DC
    • Whalley PB (1980) Multiphase flow and pressure drop. In: Hewitt GF (ed) Heat exchanger design handbook, vol 2. Hemisphere, Washington DC, pp 2.3.3-2.3.11
    • (1980) Heat Exchanger Design Handbook , vol.2 , pp. 233-2311
    • Whalley, P.B.1
  • 22
    • 0000351691 scopus 로고
    • New equations for heat transfer in turbulent pipe and channel flow
    • V Gnielinski 1976 New equations for heat transfer in turbulent pipe and channel flow Int Chem Eng 16 359 368
    • (1976) Int Chem Eng , vol.16 , pp. 359-368
    • Gnielinski, V.1
  • 23
    • 0021481949 scopus 로고
    • Measuring of the heat transfer characteristics of gas flow in fine channel heat exchangers for micro miniature refrigerators
    • DOI 10.1016/0011-2275(84)90015-8
    • PY Wu WA Little 1984 Measuring of the heat transfer characteristics of gas flow in fine channel heat exchangers for micro miniature refrigerators Cryogenics 24 415 420 10.1016/0011-2275(84)90015-8 (Pubitemid 14621415)
    • (1984) Cryogenics , vol.24 , Issue.8 , pp. 415-420
    • Wu Peiyi1    Little, W.A.2
  • 24
    • 0018458518 scopus 로고
    • Incompleteness of the flashing of supersaturated liquid and sonic ejection of the produced phases
    • DOI 10.1016/0301-9322(79)90041-7
    • C Lackme 1979 Incompleteness of the flashing of supersaturated liquid and sonic ejection of the produced phases Int J Multiph Flow 5 131 141 0406.76088 10.1016/0301-9322(79)90041-7 (Pubitemid 10416464)
    • (1979) Int J Multiphase Flow , vol.5 , Issue.2 , pp. 131-141
    • Lackme, C.1
  • 25
    • 0027643340 scopus 로고
    • A model for choked flow through cracks with inlet subcooling
    • 1144.76376 10.1016/0301-9322(93)90087-B
    • V Feburie M Giot S Granger JM Seynhaeve 1993 A model for choked flow through cracks with inlet subcooling In J Multiph Flow 19 541 562 1144.76376 10.1016/0301-9322(93)90087-B
    • (1993) J Multiph Flow , vol.19 , pp. 541-562
    • Feburie, V.1    Giot, M.2    Granger, S.3    Seynhaeve, J.M.4
  • 26
    • 0000192079 scopus 로고
    • Numerical modeling of thermodynamic non-equilibrium flow of refrigerant through capillary tubes
    • RY Li S Lin ZH Chen 1990 Numerical modeling of thermodynamic non-equilibrium flow of refrigerant through capillary tubes ASHRAE Trans 96 542 549
    • (1990) ASHRAE Trans , vol.96 , pp. 542-549
    • Li, R.Y.1    Lin, S.2    Chen, Z.H.3
  • 29
    • 79958126940 scopus 로고    scopus 로고
    • Performance of a suction-line/capillary-tube heat exchanger with alternative refrigerants
    • Wolf DA, Pate MB (2002) Performance of a suction-line/capillary-tube heat exchanger with alternative refrigerants. ASHRAE research project RP-948, Final report
    • (2002) ASHRAE Research Project RP-948, Final Report
    • Wolf, D.A.1    Pate, M.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.