메뉴 건너뛰기




Volumn 46, Issue 7, 2011, Pages 1460-1468

Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope

Author keywords

Ammonia; Indoor outdoor ratio; Library; Natural ventilation; Organic acids

Indexed keywords

AMMONIUM NITRATE; CZECH REPUBLIC; DILUTION PROCESS; GASPHASE; HIGH CONCENTRATION; HISTORICAL BUILDINGS; INDOOR AIR QUALITY; INDOOR POLLUTANTS; INDOOR POLLUTION; INDOOR/OUTDOOR RATIO; MATERIAL EXPOSURES; NATIONAL LIBRARIES; NATURAL VENTILATION; OUTDOOR AIR; OUTDOOR ENVIRONMENT; OUTDOOR TEMPERATURE; SEASONAL VARIATION; VENTILATED SYSTEM;

EID: 79951945877     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2011.01.013     Document Type: Article
Times cited : (62)

References (67)
  • 1
    • 0029416006 scopus 로고
    • Direct and indirect air pollution effects on materials including cultural monuments
    • Kunera V., Fitz S. Direct and indirect air pollution effects on materials including cultural monuments. Water Air Soil Pollut 1995, 85:153-165.
    • (1995) Water Air Soil Pollut , vol.85 , pp. 153-165
    • Kunera, V.1    Fitz, S.2
  • 4
    • 0034915074 scopus 로고    scopus 로고
    • Modeling pollutant penetration across building envelopes
    • Liu D.L., Nazaroff W.W. Modeling pollutant penetration across building envelopes. Atmos Environ 2001, 35:4451-4462.
    • (2001) Atmos Environ , vol.35 , pp. 4451-4462
    • Liu, D.L.1    Nazaroff, W.W.2
  • 5
    • 60549083966 scopus 로고    scopus 로고
    • Mathematical model of particle penetration through smooth/rough building envelop leakages
    • Tian L., Zhang G., Lin Y., Yu J., Zhou J., Zhang Q. Mathematical model of particle penetration through smooth/rough building envelop leakages. Build Environ 2009, 44:1144-1149.
    • (2009) Build Environ , vol.44 , pp. 1144-1149
    • Tian, L.1    Zhang, G.2    Lin, Y.3    Yu, J.4    Zhou, J.5    Zhang, Q.6
  • 7
    • 0002447532 scopus 로고
    • The composition of museum atmosphere
    • Brimblecombe P. The composition of museum atmosphere. Atmos Environ 1990, 24:1-8.
    • (1990) Atmos Environ , vol.24 , pp. 1-8
    • Brimblecombe, P.1
  • 10
    • 0024600995 scopus 로고
    • Background on health effects of acid aerosols
    • Lippmann M. Background on health effects of acid aerosols. Environ Health Perspect 1989, 79:3-6.
    • (1989) Environ Health Perspect , vol.79 , pp. 3-6
    • Lippmann, M.1
  • 11
    • 33645243567 scopus 로고    scopus 로고
    • Organic compounds in office environments-sensory irritation, odor, measurements and the role of reactive chemistry
    • Wolkoff P., Wilkings C.K., Clausen P.A., Nielsen G.D. Organic compounds in office environments-sensory irritation, odor, measurements and the role of reactive chemistry. Indoor Air 2006, 16:1-13.
    • (2006) Indoor Air , vol.16 , pp. 1-13
    • Wolkoff, P.1    Wilkings, C.K.2    Clausen, P.A.3    Nielsen, G.D.4
  • 12
    • 25844515837 scopus 로고    scopus 로고
    • Organic and inorganic pollutants in storage rooms of the lower Saxony state museum Hanover, Germany
    • Schieweck A., Lohrengel B., Siwinski N., Genning C., Salthammer T. organic and inorganic pollutants in storage rooms of the lower Saxony state museum Hanover, Germany. Atmos Environ 2005, 39:6098-6108.
    • (2005) Atmos Environ , vol.39 , pp. 6098-6108
    • Schieweck, A.1    Lohrengel, B.2    Siwinski, N.3    Genning, C.4    Salthammer, T.5
  • 13
    • 34047229613 scopus 로고    scopus 로고
    • Impact of reaction products from building materials and furnishings on indoor air quality - a review of recent advances in indoor chemistry
    • Uhde E., Salthammer T. Impact of reaction products from building materials and furnishings on indoor air quality - a review of recent advances in indoor chemistry. Atmos Environ 2007, 41:3111-3128.
    • (2007) Atmos Environ , vol.41 , pp. 3111-3128
    • Uhde, E.1    Salthammer, T.2
  • 14
    • 65949085369 scopus 로고    scopus 로고
    • Formaldehyde and volatile organic compounds in Hong Kong homes: concentrations and impact factors
    • Guo H., Kwok N.H., Cheng H.R., Lee S.C., Hung W.T., Li Y.S. Formaldehyde and volatile organic compounds in Hong Kong homes: concentrations and impact factors. Indoor Air 2009, 19:206-217.
    • (2009) Indoor Air , vol.19 , pp. 206-217
    • Guo, H.1    Kwok, N.H.2    Cheng, H.R.3    Lee, S.C.4    Hung, W.T.5    Li, Y.S.6
  • 16
    • 0000010968 scopus 로고    scopus 로고
    • Cellulose degradation in an acetic acid environment
    • Dupond A.L., Tétreault J. Cellulose degradation in an acetic acid environment. Stud Conserv 2000, 45:201-210.
    • (2000) Stud Conserv , vol.45 , pp. 201-210
    • Dupond, A.L.1    Tétreault, J.2
  • 17
    • 0033167847 scopus 로고    scopus 로고
    • Indoor ozone/terpene reaction as a source of indoor particles
    • Weschler C.J., Shields H.C. Indoor ozone/terpene reaction as a source of indoor particles. Atmos Environ 1999, 33:2301-2312.
    • (1999) Atmos Environ , vol.33 , pp. 2301-2312
    • Weschler, C.J.1    Shields, H.C.2
  • 18
    • 0037660440 scopus 로고    scopus 로고
    • Ozone-initiated reactions with volatile organic compounds under a simulated indoor environment
    • Fan Z., Lioy P., Weschler C., Fiedler N., Kipen H., Zhang J. Ozone-initiated reactions with volatile organic compounds under a simulated indoor environment. Environ Sci Technol 2003, 37:1811-1821.
    • (2003) Environ Sci Technol , vol.37 , pp. 1811-1821
    • Fan, Z.1    Lioy, P.2    Weschler, C.3    Fiedler, N.4    Kipen, H.5    Zhang, J.6
  • 19
    • 0034523722 scopus 로고    scopus 로고
    • Ozone and limonene in indoor air: a source of submicron particle exposure
    • Wainman T., Zhang J., Weschler C., Lioy P.J. Ozone and limonene in indoor air: a source of submicron particle exposure. Environ Health Perspect 2000, 108:1139-1145.
    • (2000) Environ Health Perspect , vol.108 , pp. 1139-1145
    • Wainman, T.1    Zhang, J.2    Weschler, C.3    Lioy, P.J.4
  • 20
    • 0023165032 scopus 로고
    • Indoor/outdoor relationship of ammonia concentration in selected office buildings
    • Sisovic A., Sega K., Kalinic N. Indoor/outdoor relationship of ammonia concentration in selected office buildings. Sci Total Environ 1987, 61:73-77.
    • (1987) Sci Total Environ , vol.61 , pp. 73-77
    • Sisovic, A.1    Sega, K.2    Kalinic, N.3
  • 21
    • 0028847172 scopus 로고
    • Indoor organic and inorganic pollutants: in-situ formation and dry deposition in southeastern Brazil
    • Allen G.A., Miguel A.H. Indoor organic and inorganic pollutants: in-situ formation and dry deposition in southeastern Brazil. Atmos Environ 1995, 29:3519-3526.
    • (1995) Atmos Environ , vol.29 , pp. 3519-3526
    • Allen, G.A.1    Miguel, A.H.2
  • 22
    • 0028363464 scopus 로고
    • The relationship between airborne acidity and ammonia in indoor environments
    • Suh H.H., Koutrakis P., Spengler J.D. The relationship between airborne acidity and ammonia in indoor environments. J Expo Anal Environ Epidemiol 1994, 4:1-23.
    • (1994) J Expo Anal Environ Epidemiol , vol.4 , pp. 1-23
    • Suh, H.H.1    Koutrakis, P.2    Spengler, J.D.3
  • 24
    • 0032918635 scopus 로고    scopus 로고
    • Indoor, outdoor and regional summer and winter concentrations of PM10, PM2.5, H+, NH4+, NO3-, NH3, and nitrous acid in homes with and without kerosene space heaters
    • Leaderer B.P., Naether L., Jankun T., Balenger K., Holford T., Toth C., et al. Indoor, outdoor and regional summer and winter concentrations of PM10, PM2.5, H+, NH4+, NO3-, NH3, and nitrous acid in homes with and without kerosene space heaters. Environ Health Perspect 1999, 107(3):223-231.
    • (1999) Environ Health Perspect , vol.107 , Issue.3 , pp. 223-231
    • Leaderer, B.P.1    Naether, L.2    Jankun, T.3    Balenger, K.4    Holford, T.5    Toth, C.6
  • 25
    • 0034976184 scopus 로고    scopus 로고
    • The relationship between indoor and outdoor airborne particles in the residential environment
    • Morawska L., He C., Hitchins J., Gilbert D., Parappukkaran S. The relationship between indoor and outdoor airborne particles in the residential environment. Atmos Environ 2001, 35:3463-3473.
    • (2001) Atmos Environ , vol.35 , pp. 3463-3473
    • Morawska, L.1    He, C.2    Hitchins, J.3    Gilbert, D.4    Parappukkaran, S.5
  • 26
    • 0030476987 scopus 로고    scopus 로고
    • Characterization of indoor air quality in the church of San Luigi dei Francesi, Rome, Italy
    • De Santis F., Allegrini I., Fazio M.C., Pasella D. Characterization of indoor air quality in the church of San Luigi dei Francesi, Rome, Italy. Int J Environ Anal Chem 1996, 64:71-81.
    • (1996) Int J Environ Anal Chem , vol.64 , pp. 71-81
    • De Santis, F.1    Allegrini, I.2    Fazio, M.C.3    Pasella, D.4
  • 27
    • 0027078602 scopus 로고
    • Determination of some atmospheric pollutants inside a museum: relationship with the concentration outside
    • De Santis F., Di Palo V., Allegrini I. Determination of some atmospheric pollutants inside a museum: relationship with the concentration outside. Sci Total Environ 1992, 127:211-223.
    • (1992) Sci Total Environ , vol.127 , pp. 211-223
    • De Santis, F.1    Di Palo, V.2    Allegrini, I.3
  • 28
    • 0025341542 scopus 로고
    • Comparison of indoor and outdoor concentrations of acid gases, ammonia and their associated salts
    • Li Y., Harrison R.H. Comparison of indoor and outdoor concentrations of acid gases, ammonia and their associated salts. Environ Technol 1990, 11:315-326.
    • (1990) Environ Technol , vol.11 , pp. 315-326
    • Li, Y.1    Harrison, R.H.2
  • 29
    • 13544259749 scopus 로고    scopus 로고
    • Relationship between outdoor and indoor air quality in eight French schools
    • Blondeau P., Lordache V., Poupard O., Genin D., Allard F. Relationship between outdoor and indoor air quality in eight French schools. Indoor Air 2005, 15:2-12.
    • (2005) Indoor Air , vol.15 , pp. 2-12
    • Blondeau, P.1    Lordache, V.2    Poupard, O.3    Genin, D.4    Allard, F.5
  • 30
    • 79951956691 scopus 로고    scopus 로고
    • [accessed 02.04.10]
    • Atlas of the Prague environment 2008, [accessed 02.04.10]. http://www.premis.cz/atlaszp/En_default.htm.
    • (2008) Atlas of the Prague environment
  • 32
    • 0035238759 scopus 로고    scopus 로고
    • Five years of nitrogen dioxide measurement with diffusion tube samplers at over 1000 sites in the UK
    • Stevenson K., Bush T., Mooney D. Five years of nitrogen dioxide measurement with diffusion tube samplers at over 1000 sites in the UK. Atmos Environ 2001, 35:281-287.
    • (2001) Atmos Environ , vol.35 , pp. 281-287
    • Stevenson, K.1    Bush, T.2    Mooney, D.3
  • 34
    • 33644841293 scopus 로고    scopus 로고
    • Laboratory and field comparison of measurements obtained using the available diffusive samplers for ozone and nitrogen dioxide in ambient air
    • Gerboles M., Buzica D., Amantini L., Lagler F. Laboratory and field comparison of measurements obtained using the available diffusive samplers for ozone and nitrogen dioxide in ambient air. J Environ Monit 2006, 8:112-119.
    • (2006) J Environ Monit , vol.8 , pp. 112-119
    • Gerboles, M.1    Buzica, D.2    Amantini, L.3    Lagler, F.4
  • 35
    • 15744377930 scopus 로고    scopus 로고
    • Council directive 1999/30/EC relating to limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in ambient air
    • EU, L163/41
    • Council directive 1999/30/EC relating to limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in ambient air. Off J Eur Communities: Legis 1999, EU, L163/41.
    • (1999) Off J Eur Communities: Legis
  • 36
    • 0023707115 scopus 로고
    • Comparative evaluation of indoor and outdoor air quality - chemical considerations
    • Harrison R.M., Colbeck I., Simmons A. Comparative evaluation of indoor and outdoor air quality - chemical considerations. Environ Technol 1988, 9:521-530.
    • (1988) Environ Technol , vol.9 , pp. 521-530
    • Harrison, R.M.1    Colbeck, I.2    Simmons, A.3
  • 37
    • 0036882544 scopus 로고    scopus 로고
    • Dry deposition of ozone on building materials. Chamber measurement and modeling of the time-dependent deposition
    • Grøntoft T. Dry deposition of ozone on building materials. Chamber measurement and modeling of the time-dependent deposition. Atmos Environ 2002, 36:5661-5670.
    • (2002) Atmos Environ , vol.36 , pp. 5661-5670
    • Grøntoft, T.1
  • 39
    • 79951948336 scopus 로고    scopus 로고
    • Natural ventilation, National Renewable Energy Laboratory (US Department of Energy), [accessed 25.06.10].
    • Walker, A. Natural ventilation, National Renewable Energy Laboratory (US Department of Energy), [accessed 25.06.10]. http://www.wbdg.org/resources/naturalventilation.php.
    • Walker, A.1
  • 41
    • 0034223303 scopus 로고    scopus 로고
    • Characterization of indoor particle sources using continuous mass and size monitors
    • Long C.M., Suh C.M., Koutrakis P. Characterization of indoor particle sources using continuous mass and size monitors. J Air Waste Manage Assoc 2000, 50:1236-1250.
    • (2000) J Air Waste Manage Assoc , vol.50 , pp. 1236-1250
    • Long, C.M.1    Suh, C.M.2    Koutrakis, P.3
  • 42
    • 0038293418 scopus 로고    scopus 로고
    • Automated measurements of ammonia and nitric acid in indoor and outdoor air
    • Fischer M.L., Littlejohn D., Lunden M., Brown N. Automated measurements of ammonia and nitric acid in indoor and outdoor air. Environ Sci Technol 2003, 37:2114-2119.
    • (2003) Environ Sci Technol , vol.37 , pp. 2114-2119
    • Fischer, M.L.1    Littlejohn, D.2    Lunden, M.3    Brown, N.4
  • 43
    • 79951944750 scopus 로고    scopus 로고
    • Assessment of environmental risk factors in museums and archives
    • Dahlin E., Henriksen J.F., Anda O. Assessment of environmental risk factors in museums and archives. Eur Cult Herit Newsl Res 1997, 10:94-97.
    • (1997) Eur Cult Herit Newsl Res , vol.10 , pp. 94-97
    • Dahlin, E.1    Henriksen, J.F.2    Anda, O.3
  • 46
    • 84949329751 scopus 로고
    • Osmotic coefficients and mean activity coefficients of univalent electrolytes in water at 25 °C
    • Hammer W.J., Wu Y.C. Osmotic coefficients and mean activity coefficients of univalent electrolytes in water at 25 °C. J Phys Chem Ref Data 1972, 1047-1099.
    • (1972) J Phys Chem Ref Data , pp. 1047-1099
    • Hammer, W.J.1    Wu, Y.C.2
  • 48
    • 34248350694 scopus 로고    scopus 로고
    • Using regional data and building leakage to assess indoor concentrations of particles of outdoor origin
    • Hering S.V., Lunden M.M., Thatcher T.L., Kirchstetter T.W., Brown N.J. Using regional data and building leakage to assess indoor concentrations of particles of outdoor origin. Aerosol Sci Technol 2007, 41:639-654.
    • (2007) Aerosol Sci Technol , vol.41 , pp. 639-654
    • Hering, S.V.1    Lunden, M.M.2    Thatcher, T.L.3    Kirchstetter, T.W.4    Brown, N.J.5
  • 51
    • 20844434666 scopus 로고    scopus 로고
    • Summary of human responses to ventilation
    • Seppänen O.A., Fisk W.J. Summary of human responses to ventilation. Indoor Air 2004, 14:102-118.
    • (2004) Indoor Air , vol.14 , pp. 102-118
    • Seppänen, O.A.1    Fisk, W.J.2
  • 52
    • 0033250198 scopus 로고    scopus 로고
    • Association of ventilation rates and CO2 concentrations with health and other responses in commercial and institutional buildings
    • Seppänen O.A., Fisk W.J., Mendell M.J. Association of ventilation rates and CO2 concentrations with health and other responses in commercial and institutional buildings. Indoor Air 1999, 9:226-252.
    • (1999) Indoor Air , vol.9 , pp. 226-252
    • Seppänen, O.A.1    Fisk, W.J.2    Mendell, M.J.3
  • 53
    • 0034546795 scopus 로고    scopus 로고
    • The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity
    • Wargocki P., Wyon D.P., Sundell J., Clausen G., Fanger P.O. The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity. Indoor Air 2000, 10:222-236.
    • (2000) Indoor Air , vol.10 , pp. 222-236
    • Wargocki, P.1    Wyon, D.P.2    Sundell, J.3    Clausen, G.4    Fanger, P.O.5
  • 55
    • 79951958271 scopus 로고    scopus 로고
    • OSHA. Office of Environmental Health Hazard Assessment, California Environmental Protection Agency. " Air-chronic RELs" [accessed 07.09.10].
    • OSHA. Office of Environmental Health Hazard Assessment, California Environmental Protection Agency. " Air-chronic RELs" [accessed 07.09.10]. http://www.oehha.org/air/chronic_rels/AllChrels.html.
  • 56
    • 79951942534 scopus 로고
    • CD 67/548/EEC. Council directive on the approximation of laws, regulations and administrative provisions relating to the classification, packaging and labelling of dangerous substances
    • CD 67/548/EEC. Council directive on the approximation of laws, regulations and administrative provisions relating to the classification, packaging and labelling of dangerous substances. Off J Eur Union: Legis 1967.
    • (1967) Off J Eur Union: Legis
  • 57
    • 70350610802 scopus 로고    scopus 로고
    • A case of indoor air pollution of ammonia emitted from concrete in a newly build office in Beijing
    • Lindgren T. A case of indoor air pollution of ammonia emitted from concrete in a newly build office in Beijing. Build Environ 2010, 45:596-600.
    • (2010) Build Environ , vol.45 , pp. 596-600
    • Lindgren, T.1
  • 59
    • 33749347024 scopus 로고    scopus 로고
    • Reference values for indoor air pollutant concentrations in new, residential buildings in Finland
    • Järnströma H., Saarelaa K., Kalliokoskib P., Pasanenc A.L. Reference values for indoor air pollutant concentrations in new, residential buildings in Finland. Atmos Environ 2006, 40:7178-7191.
    • (2006) Atmos Environ , vol.40 , pp. 7178-7191
    • Järnströma, H.1    Saarelaa, K.2    Kalliokoskib, P.3    Pasanenc, A.L.4
  • 60
    • 79951959212 scopus 로고
    • Prediction and experimental evidence for high air concentration of nitrous acid in indoor environments
    • Febo A., Perrino C. Prediction and experimental evidence for high air concentration of nitrous acid in indoor environments. Atmos Environ 1991, 19:1807-1818.
    • (1991) Atmos Environ , vol.19 , pp. 1807-1818
    • Febo, A.1    Perrino, C.2
  • 64
    • 79951954684 scopus 로고    scopus 로고
    • Air pollution and paper deterioration. Causes and remedies. Ph.D. thesis. Göteborg, Sweden: Göteborg University, Department of Chemistry
    • Johansson A. Air pollution and paper deterioration. Causes and remedies. Ph.D. thesis. Göteborg, Sweden: Göteborg University, Department of Chemistry; 2000.
    • (2000)
    • Johansson, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.