메뉴 건너뛰기




Volumn 77, Issue 3, 2011, Pages 343-355

Safety and efficacy of drug eluting stents compared with bare metal stents for saphenous vein graft interventions: A comprehensive meta-analysis of randomized trials and observational studies comprising 7,994 patients

Author keywords

bypass grafts; coronary; drug eluting stents; percutaneous coronary intervention

Indexed keywords

FIBRINOGEN RECEPTOR ANTAGONIST; PACLITAXEL; RAPAMYCIN;

EID: 79951927908     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.22720     Document Type: Article
Times cited : (51)

References (50)
  • 1
    • 20844459060 scopus 로고    scopus 로고
    • ACC/AHA 2004 guideline update for coronary artery bypasses graft surgery: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines
    • et al. American College of Cardiology; American Heart Association.
    • Eagle KA, Guyton RA, Davidoff R, et al. American College of Cardiology; American Heart Association. ACC/AHA 2004 guideline update for coronary artery bypasses graft surgery: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation 2004; 110: e340-e437.
    • (2004) Circulation , vol.110
    • Eagle, K.A.1    Guyton, R.A.2    Davidoff, R.3
  • 2
    • 0030245599 scopus 로고    scopus 로고
    • Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years
    • DOI 10.1016/S0735-1097(96)00206-9
    • Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR,. Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol 1996; 28: 616-626. (Pubitemid 26288642)
    • (1996) Journal of the American College of Cardiology , vol.28 , Issue.3 , pp. 616-626
    • FitzGibbon, G.M.1    Kafka, H.P.2    Leach, A.J.3    Keon, W.J.4    Hooper, G.D.5    Burton, J.R.6
  • 3
    • 0142043905 scopus 로고    scopus 로고
    • Percutaneous Treatment of Saphenous Vein Graft Disease: The Ongoing Challenge
    • DOI 10.1016/S0735-1097(03)01039-8
    • Baim DS,. Percutaneous treatment of saphenous vein graft disease: The ongoing challenge. J Am Coll Cardiol 2003; 42: 1370-1372. (Pubitemid 37267274)
    • (2003) Journal of the American College of Cardiology , vol.42 , Issue.8 , pp. 1370-1372
    • Baim, D.S.1
  • 4
    • 0032502337 scopus 로고    scopus 로고
    • Aortocoronary saphenous vein graft disease: Pathogenesis, predisposition, and prevention
    • Motwani JG, Topol EJ,. Aortocoronary saphenous vein graft disease: Pathogenesis, predisposition, and prevention. Circulation 1998; 97: 916-931. (Pubitemid 28113931)
    • (1998) Circulation , vol.97 , Issue.9 , pp. 916-931
    • Motwani, J.G.1    Topol, E.J.2
  • 5
    • 0029149524 scopus 로고
    • Coronary artery bypass graft disease
    • Nwasokwa ON,. Coronary artery bypass graft disease. Ann Intern Med 1995; 123: 528-545.
    • (1995) Ann Intern Med , vol.123 , pp. 528-545
    • Nwasokwa, O.N.1
  • 6
    • 39549122242 scopus 로고    scopus 로고
    • Saphenous vein graft stenting and major adverse cardiac events: A predictive model derived from a pooled analysis of 3958 patients
    • DOI 10.1161/CIRCULATIONAHA.106.651232
    • Coolong A, Baim DS, Kuntz RE, O'Malley AJ, Marulkar S, Cutlip DE, Popma JJ, Mauri L,. Saphenous vein graft stenting and major adverse cardiac events: A predictive model derived from a pooled analysis of 3958 patients. Circulation 2008; 117: 790-797. (Pubitemid 351640680)
    • (2008) Circulation , vol.117 , Issue.6 , pp. 790-797
    • Coolong, A.1    Baim, D.S.2    Kuntz, R.E.3    O'Malley, A.J.4    Marulkar, S.5    Cutlip, D.E.6    Popma, J.J.7    Mauri, L.8
  • 10
    • 34447120247 scopus 로고    scopus 로고
    • Increased Late Mortality After Sirolimus-Eluting Stents Versus Bare-Metal Stents in Diseased Saphenous Vein Grafts. Results From the Randomized DELAYED RRISC Trial
    • DOI 10.1016/j.jacc.2007.05.010, PII S0735109707016658
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, Van den Branden F, Van Langenhove G,. Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts. Results from the randomized DELAYED RRISC Trial. J Am Coll Cardiol 2007; 50: 261-267. (Pubitemid 47039289)
    • (2007) Journal of the American College of Cardiology , vol.50 , Issue.3 , pp. 261-267
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    Van Den Heuvel, P.4    Convens, C.5    Van Den Branden, F.6    Van Langenhove, G.7
  • 12
    • 57049165763 scopus 로고    scopus 로고
    • Drug-eluting stents compared with bare metal stents improve late outcome after saphenous vein graft but not after large native vessel interventions
    • BASKET Investigators.
    • Jeger RV, Schneiter S, Kaiser C, Bonetti PO, Brunner-La Rocca H, Handke M, Osswald S, Buser PT, Pfisterer ME,; BASKET Investigators. Drug-eluting stents compared with bare metal stents improve late outcome after saphenous vein graft but not after large native vessel interventions. Cardiology 2009; 112: 49-55.
    • (2009) Cardiology , vol.112 , pp. 49-55
    • Jeger, R.V.1    Schneiter, S.2    Kaiser, C.3    Bonetti, P.O.4    Brunner-La Rocca, H.5    Handke, M.6    Osswald, S.7    Buser, P.T.8    Pfisterer, M.E.9
  • 13
    • 85100415918 scopus 로고    scopus 로고
    • Higgins J.P.T., Green S., editors. (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). Available from.
    • Higgins JPT, Green S, editors. Cochrane Handbook for Systematic Reviews of Interventions. Version 5.0.1. (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). 2008. Available from.
    • (2008) Cochrane Handbook for Systematic Reviews of Interventions. Version 5.0.1
  • 14
    • 0022992740 scopus 로고
    • Meta-analysis in clinical trials
    • DOI 10.1016/0197-2456(86)90046-2
    • DerSimonian R, Laird N,. Meta-analysis in clinical trials. Control Clin Trials 1986; 7: 177-188. (Pubitemid 17189972)
    • (1986) Controlled Clinical Trials , vol.7 , Issue.3 , pp. 177-188
    • DerSimonian, R.1    Laird, N.2
  • 15
    • 0037098199 scopus 로고    scopus 로고
    • Quantifying heterogeneity in a meta-analysis
    • DOI 10.1002/sim.1186
    • Higgins JPT, Thompson SG,. Quantifying heterogeneity in a meta-analysis. Stat Med 2002; 21: 1539-1558. (Pubitemid 34746062)
    • (2002) Statistics in Medicine , vol.21 , Issue.11 , pp. 1539-1558
    • Higgins, J.P.T.1    Thompson, S.G.2
  • 22
    • 77955247118 scopus 로고    scopus 로고
    • A comparison of the long-term (2 year) safety and efficacy of drug-eluting and bare-metal stent implantation in saphenous vein grafts
    • Latib A, Ferri L, Cosgrave J, Godino C, Romagnoli E, Ielasi A, Chieffo A, Airoldi F, Montorfano M, Colombo A,. A comparison of the long-term (2 year) safety and efficacy of drug-eluting and bare-metal stent implantation in saphenous vein grafts. Eur Heart J 2008; 29 (Suppl): 455-456.
    • (2008) Eur Heart J , vol.29 , Issue.SUPPL. , pp. 455-456
    • Latib, A.1    Ferri, L.2    Cosgrave, J.3    Godino, C.4    Romagnoli, E.5    Ielasi, A.6    Chieffo, A.7    Airoldi, F.8    Montorfano, M.9    Colombo, A.10
  • 24
    • 79951875477 scopus 로고    scopus 로고
    • A comparison of drug-eluting and bare-metal stents for saphenous vein graft lesions: A report from the National Heart, Lung, and Blood Institute Dynamic Registry
    • Baldwin DE, Trost JC, Abbott J, Vlachos H, Slater JN, Beohar N, Williams DO,. A comparison of drug-eluting and bare-metal stents for saphenous vein graft lesions: A report from the National Heart, Lung, and Blood Institute Dynamic Registry. J Am Coll Cardiol 2008; 51 (Suppl): B23-B98.
    • (2008) J Am Coll Cardiol , vol.51 , Issue.SUPPL.
    • Baldwin, D.E.1    Trost, J.C.2    Abbott, J.3    Vlachos, H.4    Slater, J.N.5    Beohar, N.6    Williams, D.O.7
  • 25
    • 33846927284 scopus 로고    scopus 로고
    • Comparison of the slow-release polymerbased paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions
    • DOI 10.1007/s00392-006-0460-1
    • Wöhrle J, Nusser T, Kestler HA, Kochs M, Hombach V,. Comparison of the slow-release polymerbased paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions. Clin Res Cardiol 2007; 96: 70-76. (Pubitemid 46233208)
    • (2007) Clinical Research in Cardiology , vol.96 , Issue.2 , pp. 70-76
    • Wohrle, J.1    Nusser, T.2    Kestler, H.A.3    Kochs, M.4    Hombach, V.5
  • 27
    • 34147197569 scopus 로고    scopus 로고
    • Implantation of paclitaxel-eluting stents in saphenous vein grafts: Clinical and angiographic follow-up results from a multicentre study
    • DOI 10.1136/hrt.2006.094722
    • Hoffmann R, Pohl T, Köster R, Blindt R, Boeckstegers P, Heitzer T,. Implantation of paclitaxel-eluting stents in saphenous vein grafts: Clinical and angiographic follow-up results from a multicentre study. Heart 2007; 93: 331-334. (Pubitemid 46579523)
    • (2007) Heart , vol.93 , Issue.3 , pp. 331-334
    • Hoffmann, R.1    Pohl, T.2    Koster, R.3    Blindt, R.4    Boeckstegers, P.5    Heitzer, T.6
  • 28
    • 36549008097 scopus 로고    scopus 로고
    • Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease
    • DOI 10.1111/j.1540-8183.2007.00301.x
    • Minutello RM, Bhagan S, Sharma A, Slotwiner AJ, Feldman DM, Cuomo LJ, Wong SC,. Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease. J Interv Cardiol 2007; 20: 458-465. (Pubitemid 350179467)
    • (2007) Journal of Interventional Cardiology , vol.20 , Issue.6 , pp. 458-465
    • Minutello, R.M.1    Bhagan, S.2    Sharma, A.3    Slotwiner, A.J.4    Feldman, D.N.5    Cuomo, L.J.6    Wong, S.C.7
  • 30
    • 47549096848 scopus 로고    scopus 로고
    • Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts
    • DOI 10.1002/ccd.21599
    • Gioia G, Benassi A, Mohendra R, Chowdhury K, Masood I, Matthai W,. Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts. Catheter Cardiovasc Interv 2008; 72: 13-20. (Pubitemid 352008974)
    • (2008) Catheterization and Cardiovascular Interventions , vol.72 , Issue.1 , pp. 13-20
    • Gioia, G.1    Benassi, A.2    Mohendra, R.3    Chowdhury, K.4    Masood, I.5    Matthai, W.6
  • 31
    • 59049086905 scopus 로고    scopus 로고
    • Four-year safety and efficacy of the unrestricted use of sirolimus- and paclitaxel-eluting stents in coronary artery bypass grafts
    • van Twisk PH, Daemen J, Kukreja N, van Domburg RT, Serruys PW,. Four-year safety and efficacy of the unrestricted use of sirolimus- and paclitaxel-eluting stents in coronary artery bypass grafts. Eurointervention 2008; 4: 311-317.
    • (2008) Eurointervention , vol.4 , pp. 311-317
    • Van Twisk, P.H.1    Daemen, J.2    Kukreja, N.3    Van Domburg, R.T.4    Serruys, P.W.5
  • 34
    • 45849134854 scopus 로고    scopus 로고
    • Immediate procedural and long-term clinical outcomes following drug-eluting stent implantation to ostial saphenous vein graft lesions
    • DOI 10.1080/17482940701885400, PII 793648339
    • Kaplan S, Barlis P, Kiris A, Dimopoulos K, Celik S, Di Mario C,. Immediate procedural and long-term clinical outcomes following drug-eluting stent implantation to ostial saphenous vein graft lesions. Acute Cardiac Care 2008; 10: 88-92. (Pubitemid 351883440)
    • (2008) Acute Cardiac Care , vol.10 , Issue.2 , pp. 88-92
    • Kaplan, S.1    Barlis, P.2    Kiris, A.3    Dimopoulos, K.4    Celik, S.5    Di Mario, C.6
  • 40
    • 79951935298 scopus 로고    scopus 로고
    • Late "catch-up" in target vessel revascularization with drug eluting stents vs bare metal stents in saphenous vein graft intervention: Two year results from the strategic transcatheter evaluation of new therapies (STENT) group
    • Brodie BR, Wilson H, Stuckey T, Nussbaum M, Laurent S, Bradshaw B, Humphrey A, Metzger C, Hermiller J, Krainin F, Juk S, Cheek B, Duffy P, Simonton C,. Late "Catch-up" in target vessel revascularization with drug eluting stents vs bare metal stents in saphenous vein graft intervention: Two year results from the strategic transcatheter evaluation of new therapies (STENT) group. Am J Cardiol 2009; 104 (Suppl); 13D.
    • (2009) Am J Cardiol , vol.104 , Issue.SUPPL.
    • Brodie, B.R.1    Wilson, H.2    Stuckey, T.3    Nussbaum, M.4    Laurent, S.5    Bradshaw, B.6    Humphrey, A.7    Metzger, C.8    Hermiller, J.9    Krainin, F.10    Juk, S.11    Cheek, B.12    Duffy, P.13    Simonton, C.14
  • 42
    • 74249090627 scopus 로고    scopus 로고
    • Long-term outcomes of drug-eluting stents versus bare-metal stents in saphenous vein graft disease: Results from the prairie "real world". Stent Registry
    • Goswami NJ, Gaffigan M, Berrio G, Plessa AL, Pfeiffer AM, Markwell SJ, Mishkel GJ,. Long-term outcomes of drug-eluting stents versus bare-metal stents in saphenous vein graft disease: Results from the prairie "real world". Stent Registry. Catheter Cardiovasc Interv 2010; 75: 93-100.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 93-100
    • Goswami, N.J.1    Gaffigan, M.2    Berrio, G.3    Plessa, A.L.4    Pfeiffer, A.M.5    Markwell, S.J.6    Mishkel, G.J.7
  • 48
    • 29344457180 scopus 로고    scopus 로고
    • ACC/AHA/SCAI 2005 guideline update for Percutaneous Coronary Intervention: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (ACC/AHA/SCAI Writing Committee to update the 2001 guidelines for Percutaneous Coronary Intervention)
    • DOI 10.1016/j.jacc.2005.12.001, PII S0735109705029062
    • Smith SC Jr, Feldman TE, Hirshfeld JW Jr, Jacobs AK, Kern MJ, King SB III, Morrison DA, O'Neill WW, Schaff HV, Whitlow PL, Williams DO, Antman EM, Smith SC Jr, Adams CD, Anderson JL, Faxon DP, Fuster V, Halperin JL, Hiratzka LF, Hunt SA, Jacobs AK, Nishimura R, Ornato JP, Page RL, Riegel B,; American College of Cardiology/American Heart Association Task Force on Practice Guidelines; ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention. ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention). J Am Coll Cardiol 2006; 47: e1-e121. (Pubitemid 43005195)
    • (2006) Journal of the American College of Cardiology , vol.47 , Issue.1
    • Smith Jr., S.C.1    Feldman, T.E.2    Hirshfeld Jr., J.W.3    Jacobs, A.K.4    Kern, M.J.5    King III, S.B.6    Morrison, D.A.7    O'Neill, W.W.8    Schaff, H.V.9    Whitlow, P.L.10    Williams, D.O.11
  • 49
    • 0037058871 scopus 로고    scopus 로고
    • Lack of benefit from intravenous platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment for percutaneous interventions of aortocoronary bypass grafts: A pooled analysis of five randomized clinical trials
    • DOI 10.1161/01.CIR.0000041250.89627.A9
    • Roffi M, Mukherjee D, Chew DP, Bhatt DL, Cho L, Robbins MA, Ziada KM, Brennan DM, Ellis SG, Topol EJ,. Lack of benefit from intravenous platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment for percutaneous interventions of aortocoronary bypass grafts: A pooled analysis of five randomized clinical trials. Circulation 2002; 106: 3063-3067. (Pubitemid 35440289)
    • (2002) Circulation , vol.106 , Issue.24 , pp. 3063-3067
    • Roffi, M.1    Mukherjee, D.2    Chew, D.P.3    Bhatt, D.L.4    Cho, L.5    Robbins, M.A.6    Ziada, K.M.7    Brennan, D.M.8    Ellis, S.G.9    Topol, E.J.10
  • 50
    • 34250812581 scopus 로고    scopus 로고
    • Intravascular Ultrasound Comparison of Sirolimus-Eluting Stent Versus Bare Metal Stent Implantation in Diseased Saphenous Vein Grafts (from the RRISC [Reduction of Restenosis In Saphenous Vein Grafts With Cypher Sirolimus-Eluting Stent] Trial)
    • DOI 10.1016/j.amjcard.2007.02.052, PII S0002914907005693
    • Agostoni P, Vermeersch P, Semeraro O, Verheye S, Van Langenhove G, Van den Heuvel P, Convens C, Van den Branden F, Bruining N,. Intravascular ultrasound comparison of sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts (from the RRISC [Reduction of Restenosis In Saphenous Vein Grafts With Cypher Sirolimus-Eluting Stent] trial). Am J Cardiol 2007; 100: 52-58. (Pubitemid 46970699)
    • (2007) American Journal of Cardiology , vol.100 , Issue.1 , pp. 52-58
    • Agostoni, P.1    Vermeersch, P.2    Semeraro, O.3    Verheye, S.4    Van Langenhove, G.5    Van Den Heuvel, P.6    Convens, C.7    Van Den Branden, F.8    Bruining, N.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.