메뉴 건너뛰기




Volumn 56, Issue 5, 2011, Pages 1341-1360

Spatio-temporal (2D+T) non-rigid registration of real-time 3D echocardiography and cardiovascular MR image sequences

Author keywords

[No Author keywords available]

Indexed keywords

2-D SLICE; ALIGNED IMAGES; CARDIAC CYCLES; CARDIAC GATING; DATA SETS; DEFORMATION FIELD; IMAGING MODALITY; LOCAL PHASE; LONG AXIS; MOTION VARIATION; MR IMAGES; MUTUAL INFORMATIONS; NON-RIGID REGISTRATION ALGORITHMS; NONRIGID REGISTRATION; REAL-TIME 3D ECHOCARDIOGRAPHY; REGISTRATION ERROR; SPATIAL ALIGNMENT; SPATIO-TEMPORAL; SPATIO-TEMPORAL REGISTRATION; TEMPORAL ALIGNMENT; TEMPORAL RESOLUTION;

EID: 79951863239     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/5/008     Document Type: Article
Times cited : (21)

References (28)
  • 1
    • 27144539838 scopus 로고    scopus 로고
    • Polyrigid and polyaffine transformations: A novel geometrical tool to deal with non-rigid deformations - Application to the registration of histological slices
    • DOI 10.1016/j.media.2005.04.001, PII S1361841505000289, ITK Open Science - Combining Open Data and Open Source Software: Medical Image Analysis with the Insight Toolkit
    • Arsigny V, Pennec X and Ayache N 2005 Polyrigid and polyaffine transformations: a novel geometrical tool to deal with non-rigid deformations-application to the registrat (Pubitemid 41488115)
    • (2005) Medical Image Analysis , vol.9 , Issue.6 , pp. 507-523
    • Arsigny, V.1    Pennec, X.2    Ayache, N.3
  • 2
    • 0007663901 scopus 로고    scopus 로고
    • A new extension of linear signal processing for estimating local properties and detecting features
    • Felsberg M and Sommer G 2000 A new extension of linear signal processing for estimating local properties and detecting features Proc. DAGM pp 195-202
    • (2000) Proc. DAGM , pp. 195-202
    • Felsberg, M.1    Sommer, G.2
  • 4
    • 34548538234 scopus 로고    scopus 로고
    • Registration of multiview real-time 3-D echocardiographic sequences
    • DOI 10.1109/TMI.2007.903568
    • Grau V, Becher H and Noble J A 2007 Registration of multi-view three-dimensional echocardiographic sequences IEEE Trans. Med. Imaging 26-9 1154-65 (Pubitemid 47383438)
    • (2007) IEEE Transactions on Medical Imaging , vol.26 , Issue.9 , pp. 1154-1165
    • Grau, V.1    Becher, H.2    Noble, J.A.3
  • 6
    • 33745373482 scopus 로고    scopus 로고
    • Rapid registration of multimodal images using a reduced number of voxels
    • Huang X, Hill N A, Ren J and Peters T M 2006 Rapid registration of multimodal images using a reduced number of voxels Proc. SPIE 6141 347-56
    • (2006) Proc. SPIE , vol.6141 , pp. 347-356
    • Huang, X.1    Hill, N.A.2    Ren, J.3    Peters, T.M.4
  • 7
    • 77952859410 scopus 로고    scopus 로고
    • ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: Areport of the American college of cardiology foundation task forceon expert consensus documents
    • Hundley W G et al 2010 ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: areport of the American College of Cardiology Foundation Task Forceon Expert Consensus Documents J. Am. Coll. Cardiol. 55 2614-62
    • (2010) J. Am. Coll. Cardiol. , vol.55 , pp. 2614-2662
    • Hundley, W.G.1
  • 9
    • 77951295278 scopus 로고    scopus 로고
    • Non-parametric mixture model based evolution of level sets
    • Joshi N and Brady M 2010 Non-parametric mixture model based evolution of level sets Int. J. Comput. Vis. 88 52-68
    • (2010) Int. J. Comput. Vis. , vol.88 , pp. 52-68
    • Joshi, N.1    Brady, M.2
  • 10
    • 84958183818 scopus 로고    scopus 로고
    • Cardiac Motion Analysis from Ultrasound Sequences Using Non-rigid Registration
    • Medical Image Computing and Computer-Assisted Intervention - MICCAI 2001
    • Ledesma-Carbayo M et al 2001 Cardiac motion analysis from ultrasound sequences using nonrigid registration Medical Image Computing and Computer-Assisted Intervention-MICCAI (Lecture Notes in Computer Science vol 2208) (Berlin: Springer) pp 889-96 (Pubitemid 33352495)
    • (2001) LECTURE NOTES IN COMPUTER SCIENCE , Issue.2208 , pp. 889-896
    • Ledesma-Carbayo, M.J.1    Kybic, J.2    Desco, M.3    Santos, A.4    Unser, M.5
  • 11
    • 70349784430 scopus 로고    scopus 로고
    • Echocardiography to magnetic resonance image registration for use in image-guided cardiac catheterization procedures
    • Ma Y L, Penney G P, Rinaldi C A, Cooklin M, Razavi R and Rhode K S 2009 Echocardiography to magnetic resonance image registration for use in image-guided cardiac catheterization procedures Phys. Med. Biol. 54 5039-55
    • (2009) Phys. Med. Biol. , vol.54 , pp. 5039-5055
    • Ma, Y.L.1    Penney, G.P.2    Rinaldi, C.A.3    Cooklin, M.4    Razavi, R.5    Rhode, K.S.6
  • 12
    • 0032008619 scopus 로고    scopus 로고
    • A survey of medical image registration
    • Maintz J B A and Viergever M A 1998 A survey of medical image registration Med. Image Anal. 2 1-36 (Pubitemid 128500719)
    • (1998) Medical Image Analysis , vol.2 , Issue.1 , pp. 1-36
    • Maintz, J.B.A.1    Viergever, M.A.2
  • 14
    • 20444435515 scopus 로고    scopus 로고
    • Phase mutual information as a similarity measure for registration
    • DOI 10.1016/j.media.2005.01.002, PII S1361841505000125
    • Mellor M and Brady J M 2005 Phase mutual information as a similarity measure for registration Med. Image Anal. 9 330-43 (Pubitemid 40812567)
    • (2005) Medical Image Analysis , vol.9 , Issue.SPEC. ISS. , pp. 330-343
    • Mellor, M.1    Brady, M.2
  • 15
    • 59849086038 scopus 로고    scopus 로고
    • Real-time three-dimensional echocardiography: An integral component of the routine echocardiographic examination in adult patients
    • Mor-Avi V, Sugeng L and Lang R M 2009 Real-time three-dimensional echocardiography: an integral component of the routine echocardiographic examination in adult patients Circulation 119 314-29
    • (2009) Circulation , vol.119 , pp. 314-329
    • Mor-Avi, V.1    Sugeng, L.2    Lang, R.M.3
  • 16
    • 0034149719 scopus 로고    scopus 로고
    • 2D+T acoustic boundary detection in echocardiography
    • Mulet-Parada M and Noble J A 2000 2D+T acoustic boundary detection in echocardiography Med. Image Anal. 40 21-30
    • (2000) Med. Image Anal. , vol.40 , pp. 21-30
    • Mulet-Parada, M.1    Noble, J.A.2
  • 17
    • 10244240486 scopus 로고    scopus 로고
    • Adaptive registration using local information measures
    • DOI 10.1016/j.media.2004.03.001, PII S1361841504000167
    • Park H, Bland P H, Brock K K and Meyer C R 2004 Adaptive registration using local information measures Med. Image Anal. 8 465-73 (Pubitemid 39618470)
    • (2004) Medical Image Analysis , vol.8 , Issue.4 , pp. 465-473
    • Park, H.1    Bland, P.H.2    Brock, K.K.3    Meyer, C.R.4
  • 19
    • 0042527109 scopus 로고    scopus 로고
    • Elastic registration in the presence of intensity variations
    • Periaswamy S and Farid H 2003 Elastic registration in the presence of intensity variations IEEE Trans. Med. Imaging 7 865-74
    • (2003) IEEE Trans. Med. Imaging , vol.7 , pp. 865-874
    • Periaswamy, S.1    Farid, H.2
  • 20
    • 23844555107 scopus 로고    scopus 로고
    • Spatio-temporal free-form registration of cardiac MR image sequences
    • DOI 10.1016/j.media.2005.05.004, PII S1361841505000629
    • Perperidis D, Mohiaddin R H and Rueckert D 2005 Spatio-temporal free form registration of cardiac MR image sequences Med. Image Anal. 9 441-56 (Pubitemid 41179341)
    • (2005) Medical Image Analysis , vol.9 , Issue.SPEC. ISS. , pp. 441-456
    • Perperidis, D.1    Mohiaddin, R.H.2    Rueckert, D.3
  • 21
    • 0043028206 scopus 로고    scopus 로고
    • Mutual information based registration of medical images: A survey
    • Pluim J P, Maintz J B A and Viergever M A 2003 Mutual information based registration of medical images: a survey IEEE Trans. Med. Imaging 22 986-1004
    • (2003) IEEE Trans. Med. Imaging , vol.22 , pp. 986-1004
    • Pluim, J.P.1    Maintz, J.B.A.2    Viergever, M.A.3
  • 23
    • 0035487023 scopus 로고    scopus 로고
    • Rigid registration of 3-d ultrasound with mr images: a new approach combining intensity and gradient information
    • PII S027800620109303X
    • Roche A, Pennec X, Malandin G and Ayache N 2001 Rigid registration of 3D ultrasound with MR images: a new approach combining intensity and gradient information IEEE Trans. Med. Imaging 20 1038-49 (Pubitemid 33777721)
    • (2001) IEEE Transactions on Medical Imaging , vol.20 , Issue.10 , pp. 1038-1049
    • Roche, A.1    Pennec, A.2    Malandain, G.3    Ayache, N.4
  • 24
    • 11244294813 scopus 로고    scopus 로고
    • A connected Lie group equals the square of the exponential image
    • Wüstner M A 2003 A connected Lie group equals the square of the exponential image J. Lie Theory 13 307-9
    • (2003) J. Lie Theory , vol.13 , pp. 307-309
    • Wüstner, M.A.1
  • 25
    • 51049088590 scopus 로고    scopus 로고
    • Colorectal MRI image registration using phase mutual information from non-parametric probability density function estimator
    • Zhang W, Joshi N and Brady J M 2008 Colorectal MRI image registration using phase mutual information from non-parametric probability density function estimator ISBI: IEEE Int. Symp. on Biomedical Imaging pp 343-50
    • (2008) ISBI: IEEE Int. Symp. on Biomedical Imaging , pp. 343-350
    • Zhang, W.1    Joshi, N.2    Brady, J.M.3