Volumn 27, Issue 1, 2011, Pages 39-49

Atherosclerotic plaque components characterization and macrophage infiltration identification by intravascular ultrasound elastography based on b-mode analysis: Validation in vivo

Author keywords

Atherosclerosis; Digital image processing; Elastography; Intravascular ultrasound; Vulnerable plaque

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; AREA UNDER THE CURVE; ARTERY ENDOTHELIUM; ARTERY WALL; ARTICLE; ATHEROGENIC DIET; ATHEROSCLEROSIS; ATHEROSCLEROTIC PLAQUE; B SCAN; COMPUTER PROGRAM; CONTROLLED STUDY; ELASTOGRAPHY; HISTOPATHOLOGY; IMAGE ANALYSIS; IMMUNOHISTOCHEMISTRY; IN VIVO STUDY; INTRAVASCULAR ULTRASOUND ELASTOGRAPHY; MACROPHAGE MIGRATION; MINIPIG; NONHUMAN; RECEIVER OPERATING CHARACTERISTIC; RENAL ARTERY; SENSITIVITY AND SPECIFICITY; STRAIN DIFFERENCE;

EID: 79951856472     PISSN: 15695794     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10554-010-9659-3     Document Type: Article
Times cited : (19)

References (34)
  • 2
    • 0034622623 scopus 로고    scopus 로고
    • Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro
    • CL de Korte G Pasterkamp AF van der Steen HA Woutman N Bom 2000 Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro Circulation 102 617 623 10931800 (Pubitemid 30640660)
    • (2000) Circulation , vol.102 , Issue.6 , pp. 617-623
    • De Korte, C.L.1    Pasterkamp, G.2    Van Der Steen, A.F.W.3    Woutman, H.A.4    Bom, N.5
  • 4
    • 0028046821 scopus 로고
    • Spectral tissue strain: A new technique for imaging tissue strain using intravascular ultrasound
    • DOI 10.1016/0301-5629(94)90033-7
    • HE Talhami LS Wilson ML Neale 1994 Spectral tissue strain: a new technique for imaging tissue strain using intravascular ultrasound Ultrasound Med Biol 20 759 772 1:STN:280:DyaK2M7mslOnsg%3D%3D 10.1016/0301-5629(94)90033-7 7863565 (Pubitemid 24370184)
    • (1994) Ultrasound in Medicine and Biology , vol.20 , Issue.8 , pp. 759-772
    • Talhami, H.E.1    Wilson, L.S.2    Neale, M.L.3
  • 5
    • 0030828450 scopus 로고    scopus 로고
    • Ultrasonic measurement of differential displacement and strain in a vascular model
    • LK Ryan FS Foster 1997 Ultrasonic measurement of differential displacement and strain in a vascular model Ultrason Imaging 19 19 38 1:STN:280:DyaK2svjt1SjtQ%3D%3D 9286011 (Pubitemid 27371507)
    • (1997) Ultrasonic Imaging , vol.19 , Issue.1 , pp. 19-38
    • Ryan, L.K.1    Foster, F.S.2
  • 6
    • 0027559559 scopus 로고
    • Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review
    • 1:STN:280:DC%2BD1c7gsFWjsA%3D%3D 10.1109/58.212556 18263161
    • IA Hein WR O'Brien 1993 Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review IEEE Trans Ultrason Ferroelectr Freq Control 40 84 102 1:STN:280:DC%2BD1c7gsFWjsA%3D%3D 10.1109/58.212556 18263161
    • (1993) IEEE Trans Ultrason Ferroelectr Freq Control , vol.40 , pp. 84-102
    • Hein, I.A.1    O'Brien, W.R.2
  • 7
    • 0035113442 scopus 로고    scopus 로고
    • Strain imaging and elasticity reconstruction of arteries based on intravascular ultrasound video images
    • DOI 10.1109/10.900271, PII S0018929401001422
    • M Wan Y Li J Li Y Cui X Zhou 2001 Strain imaging and elasticity reconstruction of arteries based on intravascular ultrasound video images IEEE Trans Biomed Eng 48 116 120 1:STN:280:DC%2BD3M7ntl2isA%3D%3D 10.1109/10.900271 11235583 (Pubitemid 32165717)
    • (2001) IEEE Transactions on Biomedical Engineering , vol.48 , Issue.1 , pp. 116-120
    • Wan, M.1    Li, Y.2    Li, J.3    Cui, Y.4    Zhou, X.5
  • 8
    • 20744440323 scopus 로고    scopus 로고
    • Computer vision elastography: Speckle adaptive motion estimation for elastography using ultrasound sequences
    • DOI 10.1109/TMI.2005.848331
    • J Revell M Mirmehdi D McNally 2005 Computer vision elastography: speckle adaptive motion estimation for elastography using ultrasound sequences IEEE Trans Med Imaging 24 755 766 10.1109/TMI.2005.848331 15957599 (Pubitemid 40850527)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.6 , pp. 755-766
    • Revell, J.1    Mirmehdi, M.2    McNally, D.3
  • 9
    • 33947716501 scopus 로고    scopus 로고
    • Two-dimensional multi-level strain estimation for discontinuous tissue
    • DOI 10.1088/0031-9155/52/2/006, PII S0031915507237923, 006
    • H Shi T Varghese 2007 Two-dimensional multi-level strain estimation for discontinuous tissue Phys Med Biol 52 389 401 10.1088/0031-9155/52/2/006 17202622 (Pubitemid 46646459)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.2 , pp. 389-401
    • Shi, H.1    Varghese, T.2
  • 10
    • 1342324769 scopus 로고    scopus 로고
    • Ultrasound elastography based on multi scale estimations of regularized displacement fields
    • 10.1109/TMI.2003.822825 14964561
    • C Pellot-Barakat F Frouin MF Insana AA Herment A Herment 2004 Ultrasound elastography based on multi scale estimations of regularized displacement fields IEEE Trans Med Imaging 23 153 163 10.1109/TMI.2003.822825 14964561
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 153-163
    • Pellot-Barakat, C.1    Frouin, F.2    Insana, M.F.3    Herment, A.A.4    Herment, A.5
  • 12
    • 0029264235 scopus 로고
    • A discrete dynamic contour model
    • 1:STN:280:DC%2BD1c%2FmtlKnuw%3D%3D 10.1109/42.370398 18215806
    • S Lobregt MA Viergever 1995 A discrete dynamic contour model IEEE Trans Med Imaging 14 12 24 1:STN:280:DC%2BD1c%2FmtlKnuw%3D%3D 10.1109/42.370398 18215806
    • (1995) IEEE Trans Med Imaging , vol.14 , pp. 12-24
    • Lobregt, S.1    Viergever, M.A.2
  • 13
    • 0343729905 scopus 로고    scopus 로고
    • Intraluminal ultrasonic palpation: assessment of local and cross-sectional tissue stiffness
    • DOI 10.1016/S0301-5629(99)00169-6, PII S0301562999001696
    • EI Céspedes CL de Korte AFW vab der Steen 2000 Intraluminal ultrasonic palpation: assessment of local and cross-sectional tissue stiffness Ultrasound Med Biol 26 385 396 10.1016/S0301-5629(99)00169-6 10773368 (Pubitemid 30204550)
    • (2000) Ultrasound in Medicine and Biology , vol.26 , Issue.3 , pp. 385-396
    • Cespedes, E.I.1    De Korte, C.L.2    Van Der Steen, A.F.W.3
  • 15
    • 33644842071 scopus 로고    scopus 로고
    • Histopathologic and immunohistochemical comparison of human, rabbit, and swine aneurysms embolized with platinum coils
    • 16286401
    • D Dai YH Ding MA Danielson R Kadirvel DA Lewis HJ Cloft DF Kallmes 2005 Histopathologic and immunohistochemical comparison of human, rabbit, and swine aneurysms embolized with platinum coils Am J Neuroradiol 26 2560 2568 16286401
    • (2005) Am J Neuroradiol , vol.26 , pp. 2560-2568
    • Dai, D.1    Ding, Y.H.2    Danielson, M.A.3    Kadirvel, R.4    Lewis, D.A.5    Cloft, H.J.6    Kallmes, D.F.7
  • 16
    • 34548130803 scopus 로고    scopus 로고
    • Pathological mechanisms and dose dependency of erythrocyte-induced vulnerability of atherosclerotic plaques
    • DOI 10.1016/j.yjmcc.2007.05.023, PII S0022282807010693
    • HL Lin XS Xu HX Lu L Zhang CJ Li MX Tang HW Sun Y Liu Y Zhang 2007 Pathological mechanisms and dose dependency of erythrocyte-induced vulnerability of atherosclerotic plaque J Mol Cell Cardiol 43 272 280 1:CAS:528: DC%2BD2sXpsFamu70%3D 10.1016/j.yjmcc.2007.05.023 17628589 (Pubitemid 47301933)
    • (2007) Journal of Molecular and Cellular Cardiology , vol.43 , Issue.3 , pp. 272-280
    • Lin, H.-l.1    Xu, X.-s.2    Lu, H.-x.3    Zhang, L.4    Li, C.-j.5    Tang, M.-x.6    Sun, H.-w.7    Liu, Y.8    Zhang, Y.9
  • 20
    • 0032241115 scopus 로고    scopus 로고
    • Ultrasonic and elasticity imaging to model disease-induced changes in soft-tissue structure
    • P Chaturvedi MF Insana TJ Hall 1998 Ultrasonic and elasticity imaging to model disease-induced changes in soft-tissue structure Med Image Anal 2 325 338 1:STN:280:DyaK1M7ntVCitA%3D%3D 10.1016/S1361-8415(98)80014-5 10072200 (Pubitemid 128499394)
    • (1998) Medical Image Analysis , vol.2 , Issue.4 , pp. 325-338
    • Chaturvedi, P.1    Insana, M.F.2    Hall, T.J.3
  • 22
    • 27744440945 scopus 로고    scopus 로고
    • A general solution for catheter position effects for strain estimation in intravascular elastography
    • DOI 10.1016/j.ultrasmedbio.2005.07.004, PII S0301562905002772
    • H Shi Q Chen T Varghese 2005 A general solution for catheter position effects for strain estimation in intravascular ultrasound Ultrasound Med Biol 31 1509 1526 10.1016/j.ultrasmedbio.2005.07.004 16286029 (Pubitemid 41606265)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.11 , pp. 1509-1526
    • Shi, H.1    Chen, Q.2    Varghese, T.3
  • 23
    • 0032216608 scopus 로고    scopus 로고
    • Feature-adaptive motion tracking of ultrasound image sequences using a deformable mesh
    • PII S0278006298097389
    • F Yueng SF Levinson 1998 Feature-adaptive motion tracking of ultrasound image sequences using a deformable mesh IEEE Trans Med Imaging 17 945 956 10.1109/42.746627 (Pubitemid 128747752)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.6 , pp. 945-956
    • Yeung, F.1    Levinson, S.F.2
  • 24
    • 0036522194 scopus 로고    scopus 로고
    • Morphological and mechanical information of coronary arteries obtained with intravascular elastography: Feasibility study in vivo
    • DOI 10.1053/euhj.2001.2806
    • CL de Korte SG Carlier F Mastik MM Doyley AFW van der Steen PW Surruys N Bom 2002 Morphological and mechanical information of coronary arteries obtained with intravascular elastography Eur Heart J 23 405 413 10.1053/euhj.2001.2806 11846498 (Pubitemid 35204201)
    • (2002) European Heart Journal , vol.23 , Issue.5 , pp. 405-413
    • De Korte, C.L.1    Carlier, S.G.2    Mastik, F.3    Doyley, M.M.4    Van Der Steen, A.F.W.5    Serruysa, P.W.6    Bom, N.7
  • 25
    • 0031054999 scopus 로고    scopus 로고
    • A study of the quantitative and qualitative impact of catheter shaft angulation in a mechanical intravascular ultrasound system
    • DOI 10.1016/S0301-5629(96)00165-2, PII S0301562996001652
    • PP Kearney MP Ramo T Spencer TRD Shaw IR Starkey N McDicken GR Sutherland 1997 A study of quantitative and qualitative impact of catheter shaft angulation in a mechanical intravascular ultrasound system Ultrasound Med Biol 23 87 93 1:STN:280:DyaK2s3jsFGjsA%3D%3D 10.1016/S0301-5629(96)00165-2 9080621 (Pubitemid 27102744)
    • (1997) Ultrasound in Medicine and Biology , vol.23 , Issue.1 , pp. 87-93
    • Kearney, P.P.1    Ramo, M.P.2    Spencer, T.3    Shaw, T.R.D.4    Starkey, I.R.5    McDicken, N.6    Sutherland, G.R.7
  • 26
    • 0015267541 scopus 로고
    • Effects of aging on dynamic viscoelastic properties of the rat's thoracic aorta
    • 1:CAS:528:DyaE38XktFOhtbc%3D 10.1007/BF00592696 5064569
    • W Band WJA Goedhard AA Knoop 1972 Effects of aging on dynamic viscoelastic properties of the rat's thoracic aorta Pflugers Arch 331 357 364 1:CAS:528:DyaE38XktFOhtbc%3D 10.1007/BF00592696 5064569
    • (1972) Pflugers Arch , vol.331 , pp. 357-364
    • Band, W.1    Goedhard, W.J.A.2    Knoop, A.A.3
  • 27
    • 0037046228 scopus 로고    scopus 로고
    • Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: A Yucatan pig study
    • DOI 10.1161/01.CIR.0000014988.66572.2E
    • CL de Korte MJ Sierevogel F Mastik C Strijder JA Schaar E Velema G Pasterkamp PW Serruys AF van der Steen 2002 Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: a Yucatan pig study Circulation 105 1627 1630 10.1161/01.CIR.0000014988.66572.2E 11940537 (Pubitemid 34298602)
    • (2002) Circulation , vol.105 , Issue.14 , pp. 1627-1630
    • De Korte, C.L.1    Sierevogel, M.J.2    Mastik, F.3    Strijder, C.4    Schaar, J.A.5    Velema, E.6    Pasterkamp, G.7    Serruys, P.W.8    Van Der Steen, A.F.W.9
  • 28
    • 0030987207 scopus 로고    scopus 로고
    • Are soft echoes really soft? Intravascular ultrasound assessment of mechanical properties in human atherosclerotic tissue
    • DOI 10.1016/S0002-8703(97)70241-2
    • T Hiro CY Leung S De Guzman VJ Caiozzo AR Farvid H Karimi RH Helfant JM Tobis 1997 Are soft echoes really soft? Intravascular ultrasound assessment of mechanical properties in human atherosclerotic tissue Am Heart J 133 1 7 1:STN:280:DyaK2s7lvV2nsQ%3D%3D 10.1016/S0002-8703(97)70241-2 9006284 (Pubitemid 27124225)
    • (1997) American Heart Journal , vol.133 , Issue.1 , pp. 1-7
    • Hiro, T.1    Leung, C.Y.2    De Guzman, S.3    Caiozzo, V.J.4    Farvid, A.R.5    Karimi, H.6    Helfant, R.H.7    Tobis, J.M.8
  • 30
    • 0024330373 scopus 로고
    • Influence of plaque configuration and stress distribution on fissuring of coronary atherosclerotic plaques
    • PD Richardson MJ Davies GV Born 1989 Influence of plaque configuration and stress distribution on fissuring of coronary atherosclerotic plaques Lancet 2 941 944 1:STN:280:DyaK3c%2FhtlOgtw%3D%3D 10.1016/S0140-6736(89)90953-7 2571862 (Pubitemid 19255745)
    • (1989) Lancet , vol.2 , Issue.8669 , pp. 941-944
    • Richardson, P.D.1    Davies, M.J.2    Born, G.V.R.3
  • 32
    • 33747181852 scopus 로고    scopus 로고
    • Mechanical model of vulnerable atherosclerotic plaque rupture
    • DOI 10.1360/03yw0267
    • HJ Su M Zhang Y Zhang 2004 Mechanical model of vulnerable atherosclerotic plaque rupture Sci China Ser G 47 452 462 10.1360/03yw0267 (Pubitemid 44814971)
    • (2004) Science in China, Series G: Physics Astronomy , vol.47 , Issue.4 , pp. 452-462
    • Su, H.1    Zhang, M.2    Zhang, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.