메뉴 건너뛰기




Volumn 77, Issue 3, 2011, Pages 252-256

Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators

Author keywords

Disease transmission; Infection control; Occupational; Respiratory protective devices

Indexed keywords

ACCURACY; ADULT; ARTICLE; BREATHING; COMPARATIVE STUDY; FACIAL EXPRESSION; FEMALE; GAS MASK; HEAD MOVEMENT; HUMAN; HUMAN EXPERIMENT; HYPERPNEA; MALE; NORMAL HUMAN; NURSING STUDENT; PREDICTIVE VALUE; QUANTITATIVE ANALYSIS; QUANTITATIVE FIT TESTING; RELIABILITY; SENSITIVITY AND SPECIFICITY; USER SEAL CHECK; VERBAL COMMUNICATION;

EID: 79951850034     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2010.09.034     Document Type: Article
Times cited : (55)

References (27)
  • 1
    • 0037961585 scopus 로고    scopus 로고
    • Effectiveness of precautions against droplets and contact in prevention of nosocomial transmission of severe acute respiratory syndrome (SARS)
    • Seto W.H., Tsang D., Yung R.W.H., et al. Effectiveness of precautions against droplets and contact in prevention of nosocomial transmission of severe acute respiratory syndrome (SARS). Lancet 2003, 361:1519-1520.
    • (2003) Lancet , vol.361 , pp. 1519-1520
    • Seto, W.H.1    Tsang, D.2    Yung, R.W.H.3
  • 3
    • 31344448218 scopus 로고    scopus 로고
    • Influenza pandemics of the 20th century
    • Kilbourne E.D. Influenza pandemics of the 20th century. Emerg Infect Dis 2006, 12:9-14.
    • (2006) Emerg Infect Dis , vol.12 , pp. 9-14
    • Kilbourne, E.D.1
  • 4
    • 63849263089 scopus 로고    scopus 로고
    • Face mask use and control of respiratory virus transmission in households
    • MacIntyre C.R., Cauchemez S., Dwyer D.E., et al. Face mask use and control of respiratory virus transmission in households. Emerg Infect Dis 2009, 15:233-241.
    • (2009) Emerg Infect Dis , vol.15 , pp. 233-241
    • MacIntyre, C.R.1    Cauchemez, S.2    Dwyer, D.E.3
  • 6
    • 1642525257 scopus 로고    scopus 로고
    • Healthcare Infection Control Practices Advisory Committee. Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee
    • CDC, (RR-3)
    • Tablan O.C., Anderson L.J., Besser R., Bridges C., Hajjeh R. Healthcare Infection Control Practices Advisory Committee. Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep 2004, 26(53(RR-3)):1-36. CDC.
    • (2004) MMWR Recomm Rep , vol.26 , Issue.53 , pp. 1-36
    • Tablan, O.C.1    Anderson, L.J.2    Besser, R.3    Bridges, C.4    Hajjeh, R.5
  • 7
    • 0032509427 scopus 로고    scopus 로고
    • Laboratory performance evaluation of N95 filtering facepiece respirators
    • Centers for Disease Control and Prevention
    • Centers for Disease Control and Prevention Laboratory performance evaluation of N95 filtering facepiece respirators. Morb Mortal Wkly Rep 1996, 47:1045-1049.
    • (1996) Morb Mortal Wkly Rep , vol.47 , pp. 1045-1049
  • 8
    • 75449100592 scopus 로고    scopus 로고
    • Occupational Safety and Health Administration, US Department of Labor Regulations: OSHA
    • Occupational Safety & Health Administration Personal protective equipment. 3151-12R 2003, US Department of Labor Regulations: OSHA.
    • (2003) Personal protective equipment. 3151-12R
  • 10
    • 0021250168 scopus 로고
    • Evaluation of irritant smoke qualitative fitting test for respirators
    • Marsh J.L. Evaluation of irritant smoke qualitative fitting test for respirators. Am Indust Hyg Assoc J 1984, 45:245-249.
    • (1984) Am Indust Hyg Assoc J , vol.45 , pp. 245-249
    • Marsh, J.L.1
  • 11
    • 11244303455 scopus 로고    scopus 로고
    • Predictive value of the user seal check in determining half-face respirator fit
    • Derrick J.L., Chan Y.F., Gomersall C.D., Lui S.F. Predictive value of the user seal check in determining half-face respirator fit. J Hosp Infect 2005, 59:152-155.
    • (2005) J Hosp Infect , vol.59 , pp. 152-155
    • Derrick, J.L.1    Chan, Y.F.2    Gomersall, C.D.3    Lui, S.F.4
  • 12
    • 14744301528 scopus 로고    scopus 로고
    • Protecting healthcare staff from severe acute respirator syndrome: filtration capacity of multiple surgical masks
    • Derrick J.L., Gomersall C.D. Protecting healthcare staff from severe acute respirator syndrome: filtration capacity of multiple surgical masks. J Hosp Infect 2005, 59:365-368.
    • (2005) J Hosp Infect , vol.59 , pp. 365-368
    • Derrick, J.L.1    Gomersall, C.D.2
  • 13
    • 34548240303 scopus 로고    scopus 로고
    • Racial differences in respirator fit testing: a pilot study of whether American fit panels are representative of Chinese faces
    • Yang L., Shen H., Wu G. Racial differences in respirator fit testing: a pilot study of whether American fit panels are representative of Chinese faces. Ann Occup Hyg 2007, 51:415-421.
    • (2007) Ann Occup Hyg , vol.51 , pp. 415-421
    • Yang, L.1    Shen, H.2    Wu, G.3
  • 14
    • 84871572410 scopus 로고    scopus 로고
    • Kimberly-Clark Professional, Kimberly-Clark Worldwide Inc, Texas
    • Kimberly-Clark Professional Qualitative fit testing instructions (KCPI-0356) 2006, Kimberly-Clark Worldwide Inc, Texas.
    • (2006) Qualitative fit testing instructions (KCPI-0356)
  • 15
    • 0037215162 scopus 로고    scopus 로고
    • Use of personal protective equipment for respiratory protection
    • Sargent E.V., Gallo F. Use of personal protective equipment for respiratory protection. ILAR J 2003, 44:52-56.
    • (2003) ILAR J , vol.44 , pp. 52-56
    • Sargent, E.V.1    Gallo, F.2
  • 20
    • 0031774566 scopus 로고    scopus 로고
    • Comparison of six respirator fit test methods with an actual measurement of exposure in a simulated health care environment: part 1 - protocol development
    • Coffey C.C., Campbell D.L., Myers W.R., Zhuang Z., Das S. Comparison of six respirator fit test methods with an actual measurement of exposure in a simulated health care environment: part 1 - protocol development. Am Indust Hyg Assoc J 1998, 59:852-861.
    • (1998) Am Indust Hyg Assoc J , vol.59 , pp. 852-861
    • Coffey, C.C.1    Campbell, D.L.2    Myers, W.R.3    Zhuang, Z.4    Das, S.5
  • 22
    • 0022001561 scopus 로고
    • The sensitivity, specificity, and predictive value of traditional clinical evaluation of peripheral arterial disease: results from noninvasive testing in a defined population
    • Criqui M.H., Fronek A., Klauber M.R., Barrett-Connor E., Gabriel S. The sensitivity, specificity, and predictive value of traditional clinical evaluation of peripheral arterial disease: results from noninvasive testing in a defined population. Circulation 1985, 71:516-522.
    • (1985) Circulation , vol.71 , pp. 516-522
    • Criqui, M.H.1    Fronek, A.2    Klauber, M.R.3    Barrett-Connor, E.4    Gabriel, S.5
  • 23
    • 0035928514 scopus 로고    scopus 로고
    • Systematic reviews of evaluation of diagnostic and screening tests
    • Deeks J.J. Systematic reviews of evaluation of diagnostic and screening tests. BMJ 2001, 323:157-162.
    • (2001) BMJ , vol.323 , pp. 157-162
    • Deeks, J.J.1
  • 24
    • 70350540778 scopus 로고    scopus 로고
    • Evaluation of sensitivity and specificity of rapid influenza diagnostic tests for Novel Swine-Origin Influenza A (H1N1) virus
    • Likitnukul S., Boonsiri K. Evaluation of sensitivity and specificity of rapid influenza diagnostic tests for Novel Swine-Origin Influenza A (H1N1) virus. Pediatr Infect Dis J 2009, 28:1038-1039.
    • (2009) Pediatr Infect Dis J , vol.28 , pp. 1038-1039
    • Likitnukul, S.1    Boonsiri, K.2
  • 27
    • 0037382299 scopus 로고    scopus 로고
    • Determination of known exhalation valve damage using a negative pressure user seal check method on full facepiece respirators
    • Delaney L.J., McKay R.T., Freeman A. Determination of known exhalation valve damage using a negative pressure user seal check method on full facepiece respirators. Appl Occup Environ Hyg 2003, 18:237-243.
    • (2003) Appl Occup Environ Hyg , vol.18 , pp. 237-243
    • Delaney, L.J.1    McKay, R.T.2    Freeman, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.