메뉴 건너뛰기




Volumn 57, Issue 3, 2011, Pages 442-448

Infectious complications following conversion to buttonhole cannulation of native arteriovenous fistulas: A quality improvement report

Author keywords

Arteriovenous fistula; buttonhole; cannulation; hemodialysis; infection

Indexed keywords

ADULT; AGED; ARTERIOVENOUS FISTULA; ARTICLE; BACTEREMIA; CANNULATION; CLINICAL PROTOCOL; CONTROLLED STUDY; FEMALE; HEMODIALYSIS; HUMAN; INCIDENCE; INFECTION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; OUTCOME ASSESSMENT; SKIN FLORA; TECHNIQUE; TOTAL QUALITY MANAGEMENT;

EID: 79951768659     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.ajkd.2010.10.045     Document Type: Article
Times cited : (78)

References (20)
  • 1
    • 29744449948 scopus 로고
    • The "buttonhole" method of needle insertion takes center stage in the attempt to revive daily home hemodialysis
    • Twardowski Z. The "buttonhole" method of needle insertion takes center stage in the attempt to revive daily home hemodialysis. Contemp Dial Nephrol. 1977;18(2):18-19.
    • (1977) Contemp Dial Nephrol , vol.18 , Issue.2 , pp. 18-19
    • Twardowski, Z.1
  • 2
    • 0018640369 scopus 로고
    • Different sites versus constant sites of needle insertion into arteriovenous fistulas for treatment by repeated dialysis
    • Twardowski Z, Kubara H. Different sites versus constant sites of needle insertion into arteriovenous fistulas for treatment of repeated dialysis. Dial Transplant. 1979;8:978-980. (Pubitemid 10189683)
    • (1979) Dialysis and Transplantation , vol.8 , Issue.10 , pp. 978-980
    • Twardowski, Z.1    Kubara, H.2
  • 3
    • 0021221451 scopus 로고
    • Plastic deformation of Cimino fistula by repeated puncture
    • Krönung G. Plastic deformation of Cimino fistula by repeated puncture. Dial Transplant. 1984;13:635-638. (Pubitemid 14048669)
    • (1984) Dialysis and Transplantation , vol.13 , Issue.10 , pp. 635-638
    • Kronung, G.1
  • 4
    • 34548388489 scopus 로고    scopus 로고
    • Cannulating in haemodialysis: Rope-ladder or buttonhole technique?
    • DOI 10.1093/ndt/gfm043
    • Verhallen AM, Kooistra MP, van Jaarsveld BC. Cannulating in haemodialysis: rope-ladder or buttonhole technique? Nephrol Dial Transplant. 2007;22(9):2601-2604. (Pubitemid 47365526)
    • (2007) Nephrology Dialysis Transplantation , vol.22 , Issue.9 , pp. 2601-2604
    • Verhallen, A.M.1    Kooistra, M.P.2    Van, J.B.C.3
  • 5
    • 72949122548 scopus 로고    scopus 로고
    • Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique
    • Van Loon MM, Goovaerts T, Kessels AG, van der Sande FK, Tordoir JH. Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique. Nephrol Dial Transplant. 2010;25(1):225-230.
    • (2010) Nephrol Dial Transplant , vol.25 , Issue.1 , pp. 225-230
    • Van Loon, M.M.1    Goovaerts, T.2    Kessels, A.G.3    Van Der Sande, F.K.4    Tordoir, J.H.5
  • 6
    • 77950253420 scopus 로고    scopus 로고
    • The increasing use of hemodialysis catheters: Evidence from the DOPPS on its significance and ways to reverse it
    • Rayner HC, Pisoni RL. The increasing use of hemodialysis catheters: evidence from the DOPPS on its significance and ways to reverse it. Semin Dial. 2010;23(1):6-10.
    • (2010) Semin Dial , vol.23 , Issue.1 , pp. 6-10
    • Rayner, H.C.1    Pisoni, R.L.2
  • 7
    • 0031959987 scopus 로고    scopus 로고
    • EPIBACDIAL: A multicenter prospective study of risk factors for bacteremia in chronic hemodialysis patients
    • Hoen B, Paul-Dauphin A, Hestin D, Kessler M. EPIBACDIAL: a multicenter prospective study of risk factors for bacteremia in chronic hemodialysis patients. J Am Soc Nephrol. 1998;5:869-876.
    • (1998) J Am Soc Nephrol , vol.5 , pp. 869-876
    • Hoen, B.1    Paul-Dauphin, A.2    Hestin, D.3    Kessler, M.4
  • 8
    • 55549136085 scopus 로고    scopus 로고
    • Buttonhole cannulation - An unexpected outcome
    • Doss S, Schiller B, Moran J. Buttonhole cannulation - an unexpected outcome. Nephrol Nurs J. 2008;35:417-419.
    • (2008) Nephrol Nurs J , vol.35 , pp. 417-419
    • Doss, S.1    Schiller, B.2    Moran, J.3
  • 9
    • 77952314776 scopus 로고    scopus 로고
    • Buttonhole cannulation in hemodialysis: Improved outcomes and increased expense - Is it worth it?
    • Ludlow V. Buttonhole cannulation in hemodialysis: improved outcomes and increased expense - is it worth it? CANNT J. 2010;20(1):29-37.
    • (2010) CANNT J , vol.20 , Issue.1 , pp. 29-37
    • Ludlow, V.1
  • 10
    • 46849086949 scopus 로고    scopus 로고
    • New recommendations in the treatment of Gram-positive bacteraemia in dialysis patients
    • DOI 10.1093/ndt/gfn193
    • Labriola L, Jadoul M. New recommendations in the treatment of gram positive bacteraemia in dialysis patients. Nephrol Dial Transplant. 2008;23(7):2431-2432. (Pubitemid 351957635)
    • (2008) Nephrology Dialysis Transplantation , vol.23 , Issue.7 , pp. 2431-2432
    • Labriola, L.1    Jadoul, M.2
  • 11
    • 0000237582 scopus 로고
    • Significance tests in discrete distributions
    • Lancaster HO. Significance tests in discrete distributions. JASA. 1961;56:223-234
    • (1961) JASA , vol.56 , pp. 223-234
    • Lancaster, H.O.1
  • 12
    • 44949245796 scopus 로고    scopus 로고
    • Buttonhole cannulation: Should this become the default technique for dialysis patients with native fistulas?
    • Murcutt G. Buttonhole cannulation: should this become the default technique for dialysis patients with native fistulas? J Renal Care. 2008;34(2):101-108.
    • (2008) J Renal Care , vol.34 , Issue.2 , pp. 101-108
    • Murcutt, G.1
  • 13
    • 77953320931 scopus 로고    scopus 로고
    • Staphylococcus aureus bacteraemia and buttonhole cannulation: Long-term safety and efficacy of mupirocin prophylaxis
    • Nesrallah GE, Cuerden M, Wong JH, Pierratos A. Staphylococcus aureus bacteraemia and buttonhole cannulation: long-term safety and efficacy of mupirocin prophylaxis. Clin J Am Soc Nephrol. 2010;5(6):1047-1053.
    • (2010) Clin J Am Soc Nephrol , vol.5 , Issue.6 , pp. 1047-1053
    • Nesrallah, G.E.1    Cuerden, M.2    Wong, J.H.3    Pierratos, A.4
  • 14
    • 0043195705 scopus 로고    scopus 로고
    • Complications of vascular access: Results of a European multi centre study of the EDTNA/ERCA research board
    • Elseviers MM, Van Waeleghem JP; European Dialysis and Transplant Nurses Association/European Renal Care Association. Complications of vascular access: results of a European multi centre study of the EDTNA/ERCA Research Board. EDTNA ERCA J. 2003;29(3):163-167. (Pubitemid 37107934)
    • (2003) EDTNA-ERCA Journal , vol.29 , Issue.3 , pp. 163-167
    • Elseviers, M.M.1    Van, W.J.-P.2
  • 17
    • 42549132512 scopus 로고    scopus 로고
    • Disparities in fistula maturation persist despite preoperative vascular mapping
    • Peterson WJ, Barker J, Allon M. Disparities in fistula maturation persist despite preoperative vascular mapping. Clin J Am Soc Nephrol. 2008;3(2):437-441.
    • (2008) Clin J Am Soc Nephrol , vol.3 , Issue.2 , pp. 437-441
    • Peterson, W.J.1    Barker, J.2    Allon, M.3
  • 19
    • 79951775197 scopus 로고    scopus 로고
    • Buttonhole access: Noninvasive scab removal
    • Annual Dialysis Conference; March 7-9, 2010; Seattle, Washington; abstract
    • Hadley K, Moran J. Buttonhole access: noninvasive scab removal. [Annual Dialysis Conference; March 7-9, 2010; Seattle, Washington; abstract]. Hemodial Int. 2010;14(1):98.
    • (2010) Hemodial Int , vol.14 , Issue.1 , pp. 98
    • Hadley, K.1    Moran, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.