메뉴 건너뛰기




Volumn 26, Issue 7, 2010, Pages 821-828

UVC fluencies for preventative treatment of Pseudomonas aeruginosa contaminated polymer tubes

Author keywords

Biofilm; Catheter bacteremia; Catheter lumen; Catheter sepsis; Catheters; Disinfection; Ethylene vinyl acetate; Fluoroethylene propylene; Light emitting diodes; Liquid light guide; Pseudomonas aeruginosa; Refractive index; Sodium chloride; Sterilization; Teflon; Tubes; UV transmittance in tubes; UVC

Indexed keywords

BACTERIA (MICROORGANISMS); PSEUDOMONAS AERUGINOSA;

EID: 79951757042     PISSN: 08927014     EISSN: 10292454     Source Type: Journal    
DOI: 10.1080/08927014.2010.520314     Document Type: Article
Times cited : (14)

References (11)
  • 1
    • 34250025116 scopus 로고    scopus 로고
    • Fluid mechanics and clinical success of central venous catheters for dialysis: Answers to simple but persisting problems
    • Ash SR. 2007. Fluid mechanics and clinical success of central venous catheters for dialysis: answers to simple but persisting problems. Semin Dialysis 20: 237-256.
    • (2007) Semin Dialysis , vol.20 , pp. 237-256
    • Ash, S.R.1
  • 2
    • 77951068617 scopus 로고    scopus 로고
    • Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes
    • Bak J, Ladefoged SD, Tvede M, Begovic T, Gregersen A. 2010. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes. Biofouling 26: 31-38.
    • (2010) Biofouling , vol.26 , pp. 31-38
    • Bak, J.1    Ladefoged, S.D.2    Tvede, M.3    Begovic, T.4    Gregersen, A.5
  • 4
    • 0035029378 scopus 로고    scopus 로고
    • Biofilms and device-associated infections
    • Donlan RM. 2001. Biofilms and device-associated infections. Emerg Infect Dis 7: 277-281.
    • (2001) Emerg Infect Dis , vol.7 , pp. 277-281
    • Donlan, R.M.1
  • 5
    • 45549106144 scopus 로고    scopus 로고
    • Biofilms on central venous catheters: Is eradication possible?
    • Romeo T, editor, Berlin: Springer Verlag
    • Donlan RM. 2008. Biofilms on central venous catheters: is eradication possible? In: Romeo T, editor. Current topics in microbiology and immunology. Berlin: Springer Verlag. p. 133-161.
    • (2008) Current topics in microbiology and immunology , pp. 133-161
    • Donlan, R.M.1
  • 6
    • 33646448761 scopus 로고    scopus 로고
    • Disinfection of needless catheter connectors and access ports with alcohol may not prevent microbial entry: The promise of a novel antiseptic-barrier cap
    • Menyhay SZ, Maki DG. 2006. Disinfection of needless catheter connectors and access ports with alcohol may not prevent microbial entry: the promise of a novel antiseptic-barrier cap. Infect Cont Hosp Ep 27: 23-27.
    • (2006) Infect Cont Hosp Ep , vol.27 , pp. 23-27
    • Menyhay, S.Z.1    Maki, D.G.2
  • 7
    • 0036289711 scopus 로고    scopus 로고
    • Applying the science to the prevention of catheter-related infections
    • O'Grady PN. 2002. Applying the science to the prevention of catheter-related infections. J Crit Care 17: 114-121.
    • (2002) J Crit Care , vol.17 , pp. 114-121
    • O'Grady, P.N.1
  • 8
    • 0037156462 scopus 로고    scopus 로고
    • Intravascular catheter-related infections
    • Raad II, Hanna HA. 2002. Intravascular catheter-related infections. Arch Intern Med 162: 871-878.
    • (2002) Arch Intern Med , vol.162 , pp. 871-878
    • Raad, I.I.1    Hanna, H.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.