메뉴 건너뛰기




Volumn 58, Issue 1 PART 1, 2011, Pages 76-81

Towards sub-minute PET examination times

Author keywords

Molecular imaging; positron emission tomography (PET); time of flight imaging (TOF)

Indexed keywords

AXIAL FIELD; CO-DOPING; COUNT RATES; CRYSTAL THICKNESS; CYLINDRICAL DETECTORS; DETECTION EFFICIENCY; DETECTOR ARRAYS; DETECTOR BLOCKS; LIGHT OUTPUT; LUTETIUM OXYORTHOSILICATE; LYSO:CE; MOLECULAR IMAGING; MULTIRING; PACKING FRACTIONS; PATIENT DOSE; PERFORMANCE PARAMETERS; POSITRON CAMERA; POSITRON EMISSION; QUALITY IMAGE; RING SYSTEMS; SCINTILLATION DECAY TIME; SCINTILLATION MATERIALS; SENSITIVITY INCREASE; SIEMENS; SOLID ANGLE; SPATIAL RESOLUTION; STOPPING POWER; TIME OF FLIGHT; TIME RESOLUTION; TIME-OF-FLIGHT IMAGING (TOF); TIMING RESOLUTIONS;

EID: 79951681724     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2010.2096542     Document Type: Article
Times cited : (19)

References (19)
  • 1
    • 60449095984 scopus 로고    scopus 로고
    • Design considerations of phoswich detectors for high resolution positron emission tomography
    • Feb.
    • L. Eriksson, C. L. Melcher, M. Eriksson, H. Rothfuss, R. Grazioso, and M. Aykac, "Design considerations of phoswich detectors for high resolution positron emission tomography," IEEE Trans. Nucl. Sci., vol. 56, no. 1, pp. 182-188, Feb. 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.1 , pp. 182-188
    • Eriksson, L.1    Melcher, C.L.2    Eriksson, M.3    Rothfuss, H.4    Grazioso, R.5    Aykac, M.6
  • 4
    • 0026902676 scopus 로고
    • Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator
    • DOI 10.1109/23.159655
    • C. L. Melcher and J. S. Schweitzer, "Cerium doped lutetium oxyorthosilicate: A fast, efficient new scintillator," IEEE Trans. Nucl. Sci., vol. 39, no. 4, pp. 502-505, Aug. 1992. (Pubitemid 23608253)
    • (1992) IEEE Transactions on Nuclear Science , vol.39 , Issue.4 , pp. 502-505
    • Melcher, C.L.1    Schweitzer, J.S.2
  • 5
    • 45849110010 scopus 로고    scopus 로고
    • Effects of Ca co-doping on the scintillation properties of LSO:Ce
    • Jun.
    • M. A. Spurrier, P. Szupryczynski, A. A. Carey, and C. L. Melcher, "Effects of Ca co-doping on the scintillation properties of LSO:Ce," IEEE Trans. Nucl. Sci., vol. 55, no. 3, pp. 1178-1182, Jun. 2008.
    • (2008) IEEE Trans. Nucl. Sci. , vol.55 , Issue.3 , pp. 1178-1182
    • Spurrier, M.A.1    Szupryczynski, P.2    Carey, A.A.3    Melcher, C.L.4
  • 6
    • 67649197285 scopus 로고    scopus 로고
    • Comparison of fast scintillators with TOF PET potential
    • Jun.
    • M. Conti, L. Eriksson, H. Rothfuss, and C. L. Melcher, "Comparison of fast scintillators with TOF PET potential," IEEE Trans. Nucl. Sci., vol. 56, no. 3, pp. 926-933, Jun. 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.3 , pp. 926-933
    • Conti, M.1    Eriksson, L.2    Rothfuss, H.3    Melcher, C.L.4
  • 7
    • 0014778489 scopus 로고
    • Timing properties of scintillation counters
    • B. Bengtson and M. Moszynski, "Timing properties of scintillation counters," Nucl. Instrum. Methods, vol. 81, pp. 109-120, 1970.
    • (1970) Nucl. Instrum. Methods , vol.81 , pp. 109-120
    • Bengtson, B.1    Moszynski, M.2
  • 12
    • 0019656680 scopus 로고
    • Image reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography
    • Dec.
    • T. Tomitani, "Image reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography," IEEE Trans. Nucl. Sci., vol. NS-28, no. 6, pp. 4582-88, Dec. 1981.
    • (1981) IEEE Trans. Nucl. Sci. , vol.NS-28 , Issue.6 , pp. 4582-88
    • Tomitani, T.1
  • 13
    • 0031854801 scopus 로고    scopus 로고
    • Time-of-flight PET
    • DOI 10.1016/S0001-2998(98)80031-7
    • T. K. Lewellen, "Time-of-flight PET," Seminars Nucl. Med., vol. 28, no. 3, pp. 268-275, 1998. (Pubitemid 28371219)
    • (1998) Seminars in Nuclear Medicine , vol.28 , Issue.3 , pp. 268-275
    • Lewellen, T.K.1
  • 14
    • 0142126690 scopus 로고    scopus 로고
    • Time of flight in PET revisited
    • Oct.
    • W. W. Moses, "Time of flight in PET revisited," IEEE Trans. Nucl. Sci., vol. 50, no. 5, pp. 1325-1330, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1325-1330
    • Moses, W.W.1
  • 15
    • 60549092084 scopus 로고    scopus 로고
    • State of the art and challenges of time-of-flight PET
    • M. Conti, "State of the art and challenges of time-of-flight PET," Physica Medica, vol. 25, no. 1, pp. 1-11, 2009.
    • (2009) Physica Medica , vol.25 , Issue.1 , pp. 1-11
    • Conti, M.1
  • 16
    • 75749085816 scopus 로고    scopus 로고
    • An assessment of the impact of incorporating time-offlight information into clinical PET/CT imaging
    • C. Lois, et al., "An assessment of the impact of incorporating time-offlight information into clinical PET/CT imaging," J. Nucl. Med., vol. 51, pp. 237-245, 2010.
    • (2010) J. Nucl. Med. , vol.51 , pp. 237-245
    • Lois, C.1
  • 19
    • 0034205708 scopus 로고    scopus 로고
    • Measurements of the intrinsic rise times of common inorganic scintillators
    • Jun.
    • S. E. Derenzo, M. J. Weber, W. W. Moses, and C. Dujardin, "Measurements of the intrinsic rise times of common inorganic scintillators," IEEE Trans. Nucl. Sci., vol. 47, no. 3, pp. 860-864, Jun. 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.3 , pp. 860-864
    • Derenzo, S.E.1    Weber, M.J.2    Moses, W.W.3    Dujardin, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.